Name |
Description |
Unit |
Reqd |
Perm |
Proposed |
Status |
|
A (SMT SATNAM KAUR) |
Height |
Mt. |
|
37.63
|
14.25
|
OK
|
|
A (SMT SATNAM KAUR) |
Fourth Floor - Height |
Mt. |
2.75
|
-
|
2.85
|
OK
|
Fourth Floor - Clear Height |
Mt. |
2.75
|
-
|
2.77
|
OK
|
Fourth Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.61
|
OK
|
Third Floor - Height |
Mt. |
2.75
|
-
|
2.85
|
OK
|
Third Floor - Clear Height |
Mt. |
2.75
|
-
|
2.77
|
OK
|
Third Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.61
|
OK
|
Second Floor - Height |
Mt. |
2.75
|
-
|
2.85
|
OK
|
Second Floor - Clear Height |
Mt. |
2.75
|
-
|
2.77
|
OK
|
Second Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.61
|
OK
|
First Floor - Height |
Mt. |
2.75
|
-
|
2.85
|
OK
|
First Floor - Clear Height |
Mt. |
2.75
|
-
|
2.77
|
OK
|
First Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.61
|
OK
|
Ground Floor - Height |
Mt. |
2.75
|
-
|
2.85
|
OK
|
Ground Floor - Clear Height |
Mt. |
2.75
|
-
|
2.77
|
OK
|
Ground Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.61
|
OK
|
Basement Floor - Height |
Mt. |
2.40
|
-
|
3.00
|
OK
|
Basement Floor - Clear Height |
Mt. |
2.40
|
-
|
2.92
|
OK
|
Basement Floor - Beam Clear Height |
Mt. |
2.10
|
-
|
2.76
|
OK
|
|
A (SMT SATNAM KAUR) |
Terrace Floor - Height |
Mt. |
1.00
|
1.20
|
1.07
|
OK
|
|
A (SMT SATNAM KAUR) |
Basement Floor - Height Below GL |
Mt. |
|
-
|
3.00
|
OK
|
Basement Floor - Area |
Sq.Mt. |
|
-
|
163.46
|
OK
|
Basement Floor - Ventilation Area (Sq.mt.) |
Sq.Mt. |
-
|
|
-
|
OK
|
|
A (SMT SATNAM KAUR) |
Area |
Sq.Mt. |
|
-
|
163.46
|
OK
|
Status |
|
|
|
-
|
OK
|
Total |
Area |
Sq.Mt. |
|
-
|
163.46
|
OK
|
|
A (SMT SATNAM KAUR) |
No. of Basement Floor |
No. |
|
1
|
1
|
OK
|
|
A (SMT SATNAM KAUR) |
No. of Floors |
No. |
|
-
|
5
|
OK
|
No. of Tenements |
No. |
|
-
|
10
|
OK
|
|
A (SMT SATNAM KAUR) |
Number Of Lift(s) |
No. |
-
|
|
1
|
OK
|
Number Of Strature Lift(s) |
No. |
-
|
|
-
|
OK
|
Capacity Of Lift(s) Passanger |
No. |
-
|
|
6
|
OK
|
|
A (SMT SATNAM KAUR) |
BASEMENT FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.88
|
OK
|
BASEMENT FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
GROUND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.88
|
OK
|
GROUND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.88
|
OK
|
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Width |
Mt. |
1.70
|
|
1.88
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
|
BASEMENT FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
-
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
GROUND FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.095
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.095
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
TERRACE FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
-
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
-
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
-
|
-
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
2.440
|
OK
|
|
Toilet |
Area |
Sq.Mt. |
-
|
5.00
|
2.47
|
OK
|
Width |
Mt. |
-
|
-
|
1.09
|
OK
|
Depth |
Mt. |
-
|
-
|
2.28
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Sewage Treatment Plant |
Area |
Sq.Mt. |
-
|
-
|
0.90
|
OK
|
Width |
Mt. |
-
|
-
|
0.75
|
OK
|
Depth |
Mt. |
-
|
-
|
1.21
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
RAIN WATER HARVESTING |
Area |
Sq.Mt. |
-
|
-
|
2.36
|
OK
|
Width |
Mt. |
-
|
-
|
1.09
|
OK
|
Depth |
Mt. |
-
|
-
|
2.16
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
ENT.GATE |
Area |
Sq.Mt. |
-
|
-
|
1.62
|
OK
|
Width |
Mt. |
-
|
-
|
0.43
|
OK
|
Depth |
Mt. |
-
|
-
|
3.75
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Entrance Lobby |
Area |
Sq.Mt. |
-
|
12.00
|
2.82
|
OK
|
Width |
Mt. |
-
|
-
|
1.23
|
OK
|
Depth |
Mt. |
-
|
-
|
2.30
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Area |
Sq.Mt. |
-
|
12.00
|
2.82
|
OK
|
Width |
Mt. |
-
|
-
|
1.23
|
OK
|
Depth |
Mt. |
-
|
-
|
2.30
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Area |
Sq.Mt. |
-
|
12.00
|
2.82
|
OK
|
Width |
Mt. |
-
|
-
|
1.23
|
OK
|
Depth |
Mt. |
-
|
-
|
2.30
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Area |
Sq.Mt. |
-
|
12.00
|
2.82
|
OK
|
Width |
Mt. |
-
|
-
|
1.23
|
OK
|
Depth |
Mt. |
-
|
-
|
2.30
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
SOLAR HEATING SYSTEM |
Area |
Sq.Mt. |
-
|
-
|
2.27
|
OK
|
Width |
Mt. |
-
|
-
|
1.09
|
OK
|
Depth |
Mt. |
-
|
-
|
2.08
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Generator Room |
Area |
Sq.Mt. |
-
|
-
|
2.18
|
OK
|
Width |
Mt. |
-
|
-
|
1.09
|
OK
|
Depth |
Mt. |
-
|
-
|
2.01
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
|
A (SMT SATNAM KAUR) |
Rain Water Harvesting - No |
No. |
1
|
-
|
1
|
OK
|
Entrance Gate - No |
No. |
1
|
-
|
1
|
OK
|
|
PLOT |
7.87 mt. long 1.50 mt. High 4.10 mt. Wide Natural Slope - Width |
Mt. |
-
|
|
4.10
|
OK
|
7.87 mt. long 1.50 mt. High 4.10 mt. Wide Natural Slope - Depth |
Mt. |
-
|
|
1.50
|
OK
|
7.87 mt. long 1.50 mt. High 4.10 mt. Wide Natural Slope - Slope |
Ratio |
-
|
-
|
-
|
OK
|
Ramp No. |
A (SMT SATNAM KAUR) - BASEMENT FLOOR PLAN - No. |
No. |
1
|
|
1
|
OK
|
|
|
[-] Rules
Topic |
Rule |
Plot Level |
Plot Area |
No rule provided for Min. Plot size for proposed Use
|
Plot Width |
No rule provided for Min. Plot size for proposed Use
|
Plot Depth |
No rule provided for Min. Plot size for proposed Use
|
Access Width |
The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
|
Plot Frontage |
No rule provided for Min. Plot size for proposed Use
|
FAR Area |
(1)
In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2)
For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Consumed FAR |
(1)
In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2)
For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Common Plot Area |
In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
|
Common Plot |
(1)
In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2)
;
|
Tree Number |
4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule |
For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 3.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
|
Basement Margin Rule |
In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
|
Building Level |
Building Height |
For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
|
Parapet Height |
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Below GL Floor Height |
,
|
Basement Floor No. |
Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
|
Floor Number |
For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
|
Lift Count |
(1)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2)
For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
|
Lift |
(1)
The area of lift well shall not be counted for F.A.R calculation)
(2)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3)
The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5)
-
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
No Rule Defined
(4)
; No Rule Defined
|
Ramp |
No Need to Check Natural Slope width, Depth or height. ;
|
Ramp No. |
For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
|
Plot / Building Level |
Accessory Use |
(1)
Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2)
No need to check distance from Building Toilet
(3)
-
(4)
No need to check distance from Building Sewage Treatment Plant
(5)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6)
No need to check distance from Building RAIN WATER HARVESTING
(7)
No need to check distance from Building ENT.GATE
(8)
Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(9)
No need to check distance from Building Entrance Lobby
(10)
-
(11)
No need to check distance from Building SOLAR HEATING SYSTEM
(12)
Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(13)
No need to check distance from Building Generator Room
|
Accessory Use Number |
(1)
Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2)
In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
|
Building Level (Rooms) |
|