General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0041/W09/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDimna
Taluka16
Architect Details
Architect NameAnoop Kumar
License No.MNAC/ENG/0006/2016
Architect AddressFlat No.- 4503, Cheese Berry, Shara Garden City-Adityapur-II
Architect EmailIDanoop7117@gmail.com
Architect Mobile No9431117509
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2096
North -
South -
EastRoad Width - 20.0 MTR WIDE MAIN ROAD
West -
Owner's Details
NameSMT SATNAM KAUR
AddressDIMNA ROAD MANGO, JAMSHEDPUR
Email IDRAVIM76@GMAIL.COM
Mobile No6200687527
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 323.29
2 Plot area as per Document by Applicant 323.29
3 Physical area measured at site 323.29
4 Area as per Site Visit (Site Visit Report) 323.29
5Area as per Drawing 322.36

Area of Plot Considered : 322.36

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 322.36
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 322.36
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 285.56
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 36.79
36.79
Balance Plot Area 285.56

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 193.42
Proposed Coverage Area ( 50.71 % ) 163.46
Total Prop. Coverage Area ( 50.71 % ) 163.46
Balance coverage area ( 9.29 % ) 29.96
FAR CHECK
Perm. FAR Area ( 2.50 ) 805.90
Total Perm. FAR area 805.90
Residential FAR 790.78
Proposed FAR Area 802.00
Total Proposed FAR Area 802.00
Consumed FAR (Factor) 2.49
Balance FAR Area 3.90
BUA CHECK
Total Proposed BuiltUp Area 996.84


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 20 20.00
Proposed Road Width as per Master Plan 20 -
Road Widening Width 0 -
Plot size (as per measurement) 323.29 322.36
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 322.36 OK
Plot Width Mt. - - 10.12 OK
Plot Depth Mt. - - 31.85 OK
Access Width Mt. 6.10 - 20.00 OK
Plot Frontage Mt. - - 10.12 OK
Coverage Area Sq.Mt. - 193.42 163.46 OK
FAR Area Sq.Mt. - 805.90 802.00 OK
Consumed FAR Sq.Mt. - 2.50 2.49 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 32.24 36.79 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 36.79 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.70 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 12 OK
Car In Area Sq.Mt. - - 37.50 OK
Four Stack.Car In Area Sq.Mt. - - 112.50 OK
Total Car In Area Sq.Mt. 125.00 - 150.00 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 13.50 OK
Parallel Visitor's Car Parking In Area Sq.Mt. - - 13.50 OK
TwoWheeler In Area Sq.Mt. - - 26.00 OK
Total TwoWheeler In Area Sq.Mt. 20.00 - 26.00 OK
Other Parking In Area Sq.Mt. - - 97.15 OK
A-1 (SMT SATNAM KAUR) Front Margin... 20 MTR WIDE ROAD Access Road Mt. 4.00 - 7.63 OK
Rear Margin Mt. 3.50 - 3.53 OK
Side1 Margin Mt. 1.00 - 1.04 OK
Side2 Margin Mt. 1.00 - 1.19 OK
A-1 (SMT SATNAM KAUR) Basement Front Margin... 20 MTR WIDE ROAD Access Road Mt. 3.00 - 7.63 OK
Basement Rear Margin Mt. 3.00 - 3.53 OK
Basement Side1 Margin Mt. 1.00 - 1.04 OK
Basement Side2 Margin Mt. 1.00 - 1.19 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SMT SATNAM KAUR) Height Mt. 37.63 14.25 OK
A (SMT SATNAM KAUR) Fourth Floor - Height Mt. 2.75 - 2.85 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.77 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
Third Floor - Height Mt. 2.75 - 2.85 OK
Third Floor - Clear Height Mt. 2.75 - 2.77 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Clear Height Mt. 2.75 - 2.77 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
First Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Clear Height Mt. 2.75 - 2.77 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Clear Height Mt. 2.75 - 2.77 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
Basement Floor - Height Mt. 2.40 - 3.00 OK
Basement Floor - Clear Height Mt. 2.40 - 2.92 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.76 OK
A (SMT SATNAM KAUR) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (SMT SATNAM KAUR) Basement Floor - Height Below GL Mt. - 3.00 OK
Basement Floor - Area Sq.Mt. - 163.46 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (SMT SATNAM KAUR) Area Sq.Mt. - 163.46 OK
Status - OK
Total Area Sq.Mt. - 163.46 OK
A (SMT SATNAM KAUR) No. of Basement Floor No. 1 1 OK
A (SMT SATNAM KAUR) No. of Floors No. - 5 OK
No. of Tenements No. - 10 OK
A (SMT SATNAM KAUR) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (SMT SATNAM KAUR) BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 1.88 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 1.92 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.88 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.92 OK
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.88 OK
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.92 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.88 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.92 OK
BASEMENT FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.227 OK
Staircase -3FL - Tread Width Mt. 0.250 0.307 OK
Staircase -3FL - Riser Height Mt. 0.200 - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.227 OK
Staircase -3FL - Tread Width Mt. 0.250 0.307 OK
Staircase -3FL - Riser Height Mt. 0.200 0.095 OK
Staircase -3FL - Riser No. On Flight No. - 8 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.227 OK
Staircase -3FL - Tread Width Mt. 0.250 0.307 OK
Staircase -3FL - Riser Height Mt. 0.200 0.095 OK
Staircase -3FL - Riser No. On Flight No. - 8 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 1.227 OK
Staircase -3FL - Tread Width Mt. - 0.307 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - 2.440 OK
Toilet Area Sq.Mt. - 5.00 2.47 OK
Width Mt. - - 1.09 OK
Depth Mt. - - 2.28 OK
Height Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.90 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 1.21 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.36 OK
Width Mt. - - 1.09 OK
Depth Mt. - - 2.16 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.62 OK
Width Mt. - - 0.43 OK
Depth Mt. - - 3.75 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 2.82 OK
Width Mt. - - 1.23 OK
Depth Mt. - - 2.30 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 2.82 OK
Width Mt. - - 1.23 OK
Depth Mt. - - 2.30 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 2.82 OK
Width Mt. - - 1.23 OK
Depth Mt. - - 2.30 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 2.82 OK
Width Mt. - - 1.23 OK
Depth Mt. - - 2.30 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.27 OK
Width Mt. - - 1.09 OK
Depth Mt. - - 2.08 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 2.18 OK
Width Mt. - - 1.09 OK
Depth Mt. - - 2.01 OK
Height Mt. - - - OK
A (SMT SATNAM KAUR) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 7.87 mt. long 1.50 mt. High 4.10 mt. Wide Natural Slope - Width Mt. - 4.10 OK
7.87 mt. long 1.50 mt. High 4.10 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
7.87 mt. long 1.50 mt. High 4.10 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (SMT SATNAM KAUR) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 3.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(9) No need to check distance from Building Entrance Lobby
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
(12) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(13) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)