No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.59  
Version Date: 16/10/2020 
Report Generated On: 31-07-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0030/W09/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameKunal Sinha Mahapatra
License No.MNAC/ENG/0006/2017
Architect AddressG/2, D-Block, D-Choudhury Madusudhan complex, Dimna more, Mango, Jamshedpur
Architect EmailIDkunal.sinha1977@gmail.com
Architect Mobile No9903304812
Plot Details
Plot Use Residential
Plot SubUse Row House
PlotNearbyReligiousStructure NA
Plot/SubPlot No4637 (NEW)
North -
South -
East -
West -
Owner's Details
NameANAND KUMAR PANDEY
AddressHo. No. 101, ASHIRWAD NAGAR, NEW SHARMA LINE, OLD ULIDIH, MANGO, JAMSHEDPUR
Email IDlic.mayihelpyou@gmail.com
Mobile No9304029095
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 66.89
2 Plot area as per Document by Applicant 66.89
3 Physical area measured at site 66.89
4 Area as per Site Visit (Site Visit Report) 66.89
5Area as per Drawing 66.89

Area of Plot Considered : 66.89

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Row House
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 66.89
Deduction from Gross Plot area
- Surrender Free of Cost 2.66
2.66
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 64.23
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 60.79
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 2.66
- Common Plot 3.44
6.10
Balance Plot Area 60.79

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 44.96
Proposed Coverage Area ( 63.81 % ) 40.98
Total Prop. Coverage Area ( 63.81 % ) 40.98
Balance coverage area ( 6.20 % ) 3.98
FAR CHECK
Perm. FAR Area ( 1.50 ) 100.33
Total Perm. FAR area 100.33
Residential FAR 40.98
Proposed FAR Area 40.98
Total Proposed FAR Area 40.98
Consumed FAR (Factor) 0.61
Balance FAR Area 59.35
BUA CHECK
Total Proposed BuiltUp Area 40.98


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 4.5 4.50
Proposed Road Width as per Master Plan 4.5 -
Road Widening Width 0 0.30
Plot size (as per measurement) 66.89 66.89
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 3.21 3.44 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 3.44 0.00 0.00 - 0.80 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 2 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (ANAND PANDEY) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (ANAND PANDEY) 8.25 3.00 3.00 3.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (ANAND PANDEY) Ground Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (ANAND PANDEY) Terrace Floor - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (ANAND PANDEY) G + 2 1 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
44.96 40.98 OK
70% 63.81%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (ANAND PANDEY) - 40.98
  Total Prop. Coverage Area - 40.98
  Total Coverage Area 44.96 40.98

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (ANAND PANDEY) 1 40.98 40.98 40.98 40.98 01
Grand Total : 1 40.98 40.98 40.98 40.98 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (ANAND PANDEY)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 40.98 40.98 40.98 40.98
Terrace Floor 0.00 0.00 0.00 0.00
Total : 40.98 40.98 40.98 40.98


[-] UnitBUA Table for Building :A (ANAND PANDEY)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN GR FL FLAT 40.98 36.41 4 1
Total: - - 40.98 36.41 4 1


[-] Building :A (ANAND PANDEY)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 40.98 40.98 40.98 40.98 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 40.98 40.98 40.98 40.98 01
Total Number of Same Buildings : 1
Total : 40.98 40.98 40.98 40.98 01
[-] Table 4c-2

  FAR Area
Building FAR Area:40.98
Existing FAR Area :0.00
Perm.
100.33
Prop.
40.98
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (ANAND PANDEY) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 1.50 1.20 0.90 0.90 0.90 0.90 - 0.00 Failed


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (ANAND PANDEY) BldgLine for 4.5 M WIDE ROAD 0.30 1.50 4.5 M WIDE ROAD ROAD WIDENING AREA(SURRENDERED FREE OF COST) 0.30 0.30 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (ANAND PANDEY)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


No Staircase Found


   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING 1.20 DIA & 3.6 M DEPTH - - 1.10 - - 1.18 - - 1.18 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (ANAND PANDEY) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (ANAND PANDEY)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 50.00 64.23 OK
  Plot Width - 8.87 OK
  Plot Depth - 7.25 OK
  Access Width - 4.50 OK
  Plot Frontage - 8.87 OK
  Coverage Area 44.96 40.98 OK
  FAR Area
Bldg. FAR Area : 40.98
Sanctioned FAR Area :0.00
100.33 40.98 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth upto 10.0 mt. and Plot width upto 10.0 mt., Margin required in Front shall be 1.5 mt., Rear 0.9 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING 1.20 DIA & 3.6 M DEPTH
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)