Topic |
Rule |
Plot Level |
Plot Area |
The depth of plot shall be max. 10 mt. for Shop-cum-Residence Building {As per Chapter VII, Rule No. 66.8 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Plot Width |
The depth of plot shall be max. 10 mt. for Shop-cum-Residence Building {As per Chapter VII, Rule No. 66.8 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Plot Depth |
The depth of plot shall be max. 10 mt. for Shop-cum-Residence Building {As per Chapter VII, Rule No. 66.8 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Plot Frontage |
The depth of plot shall be max. 10 mt. for Shop-cum-Residence Building {As per Chapter VII, Rule No. 66.8 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
FAR Area |
(1)
0.0
(2)
0.0
|
Consumed FAR |
(1)
0.0
(2)
0.0
|
Tree Number |
Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
DriveWay Rule |
(1)
For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2)
The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
|
Building Level |
Building Height |
For shop cum residence, Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 12.0 mt. {As per Chapter VII}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
No rule found for Mini. reqd Floor height
|
Below GL Floor Height |
,
|
Balcony |
Projected balcony may be allowed with a width of 1.2 mt. where the setback is more than 4.5 mt. and 4.5 mt. respectively clear driveway is available for the Fire tender movement {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Passage |
No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
|
Lift |
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
|
StairCase |
(1)
Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2)
; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4)
; No Rule Defined
(5)
No Rule Defined
(6)
; No Rule Defined
(7)
No Rule Defined
(8)
; Number of riser shall not exceed 14 per flight of stairs. {As per Rule No. 43.5.2.6}
|
Ramp No. |
For parking spaces in basements and upper storey of parking floors, if car parking is more then 40 two ramp of minimum of 3.30m width if it is straight and 3.60m width if it is curved and 5.4m width if one ramp is required shall be provided
|
Arch Projection |
(1)
Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
(2)
Cupboard up to 0.60 mt. in width shall be permitted. {As per Rule 6.26.1 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
|
Plot / Building Level |
Accessory Use |
(1)
- FIRE Refuse Chute
(2)
Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR Toilet
(3)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area RAIN WATER HARVESTING 3.00 DIA & 3.6 M DEPTH
(4)
Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m METER ROOM
(5)
ENT.GATE
|