No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 21-03-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0070/W8/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameMOHAMMAD BELAL NASIR
License No.MNAC/ENG/0007/2016
Architect AddressHOLDING No: 02, CROSS ROAD No:1/D, AZAD NAGAR, MANGO
Architect EmailIDdreamdesign.jsr.bn@gmail.com
Architect Mobile No9835307058
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No3148
North -
South -
East -
West -
Owner's Details
NameMR. MOHAMMAD MOINUDDIN
AddressROAD NO. 16 JAWAHAR NAGAR, MANGO JAMSHEDPUR
Email IDtariq-azam@rediffmail.com
Mobile No7870968930
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 267.59
2 Plot area as per Document by Applicant 267.28
3 Physical area measured at site 267.28
4 Area as per Site Visit (Site Visit Report) 267.28
5Area as per Drawing 267.28

Area of Plot Considered : 267.28

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 267.28
Deduction from Gross Plot area
- Surrender Free of Cost 6.25
6.25
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 261.02
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 235.23
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 6.25
- Common Plot 25.80
32.05
Balance Plot Area 235.23

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 156.61
Proposed Coverage Area ( 58.44 % ) 152.53
Total Prop. Coverage Area ( 58.44 % ) 152.53
Balance coverage area ( 1.56 % ) 4.08
FAR CHECK
Perm. FAR Area ( 2.00 ) 534.56
Total Perm. FAR area 534.56
Residential FAR 517.38
Proposed FAR Area 530.38
Total Proposed FAR Area 530.38
Consumed FAR (Factor) 1.98
Balance FAR Area 4.18
BUA CHECK
Total Proposed BuiltUp Area 737.37


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 0.55
Plot size (as per measurement) 267.28 267.28
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 261.02 OK
Plot Width Mt. - - 10.97 OK
Plot Depth Mt. - - 23.79 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 11.38 OK
Coverage Area Sq.Mt. - 156.61 152.53 OK
FAR Area Sq.Mt. - 534.56 530.38 OK
Consumed FAR Sq.Mt. - 2.00 1.98 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 13.05 25.80 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 25.80 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.68 OK
Tree Cover (Plantation) - Angle Degree - 88.22 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 19 OK
A-1 (MOHAMMAD MOINUDDIN) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 3.09 OK
Rear Margin Mt. 2.25 - 2.51 OK
Side1 Margin Mt. 0.90 - 0.92 OK
Side2 Margin Mt. 0.90 - 1.26 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (MOHAMMAD MOINUDDIN) Height Mt. 12.79 11.52 OK
A (MOHAMMAD MOINUDDIN) Third Floor - Height Mt. 2.75 - 2.88 OK
Third Floor - Clear Height Mt. 2.75 - 2.77 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
Second Floor - Height Mt. 2.75 - 2.88 OK
Second Floor - Clear Height Mt. 2.75 - 2.76 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
First Floor - Height Mt. 2.75 - 2.88 OK
First Floor - Clear Height Mt. 2.75 - 2.77 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
Ground Floor - Height Mt. 2.75 - 2.88 OK
Ground Floor - Clear Height Mt. 2.75 - 2.77 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
A (MOHAMMAD MOINUDDIN) Terrace Floor - Height Mt. - - 1.00 OK
A (MOHAMMAD MOINUDDIN) No. of Floors No. G + 4 4 OK
No. of Tenements No. - 1 OK
A (MOHAMMAD MOINUDDIN) GROUND FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.71 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.91 OK
SECOND FLOOR PLAN - Lift - Width Mt. 1.70 1.71 OK
SECOND FLOOR PLAN - Lift - Depth Mt. 1.90 1.91 OK
THIRD FLOOR PLAN - Lift - Width Mt. 1.70 1.71 OK
THIRD FLOOR PLAN - Lift - Depth Mt. 1.90 1.91 OK
TERRACE FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.067 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.115 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.067 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.115 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.067 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.115 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.067 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.115 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.067 OK
STAIRCASE - Tread Width Mt. - 0.267 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 1.446 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.68 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 1.11 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.68 OK
Width Mt. - - 1.46 OK
Depth Mt. - - 1.47 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.53 OK
Width Mt. - - 0.12 OK
Depth Mt. - - 4.45 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.83 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 1.34 OK
Height Mt. - - - OK
A (MOHAMMAD MOINUDDIN) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
   

[-] Building:A (MOHAMMAD MOINUDDIN)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:FIRST FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop

[-] Floor:SECOND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop

[-] Floor:THIRD FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop






[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For new area, on Road width 6.1-7.5 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For new area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 16}
Lift (1) -
(2) The area of lift well shall not be counted for F.A.R calculation)
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)