No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.61  
Version Date: 16/10/2020 
Report Generated On: 19-10-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0036/W09/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect Namesm shahreyar
License No.MNAC/ARC/0026/2017
Architect AddressAL-TAUHID APARTMENT,GROUND FLOOR,NERA ROAD NO-13,OLD PURULIA ROAD(E),ZAKIRNAGAR,AZADNAGAR,MANGO
Architect EmailIDadiction.arch@gmail.com
Architect Mobile No7004876409
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1518(part),1516,1515
NorthPlot No. - society plot no-88
SouthPlot No. - society plot no-86
EastPlot No. - 4.8
WestPlot No. - society alley
Owner's Details
NameRANJU SHARMA
Addresschandrawati nagar
Email IDashokkumarinspector1960@gmail.com
Mobile No9631081391
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 371.74
2 Plot area as per Document by Applicant 371.55
3 Physical area measured at site 371.55
4 Area as per Site Visit (Site Visit Report) 371.55
5Area as per Drawing 371.55

Area of Plot Considered : 371.55

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 371.55
Deduction from Gross Plot area
- Surrender Free of Cost 9.91
9.91
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 361.64
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 325.53
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 9.91
- Common Plot 36.11
46.02
Balance Plot Area 325.53

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 216.98
Proposed Coverage Area ( 42.54 % ) 153.83
Total Prop. Coverage Area ( 42.54 % ) 153.83
Balance coverage area ( 17.46 % ) 63.15
FAR CHECK
Perm. FAR Area ( 1.80 ) 668.79
Total Perm. FAR area 668.79
Residential FAR 312.01
Proposed FAR Area 312.01
Total Proposed FAR Area 312.01
Consumed FAR (Factor) 0.84
Balance FAR Area 356.78
BUA CHECK
Total Proposed BuiltUp Area 341.81


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 4.8 4.80
Proposed Road Width as per Master Plan 4.8 -
Road Widening Width 0 0.65
Plot size (as per measurement) 371.55 371.55
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 361.64 OK
Plot Width Mt. - - 15.24 OK
Plot Depth Mt. - - 23.73 OK
Access Width Mt. - - 4.80 OK
Plot Frontage Mt. - - 15.24 OK
Coverage Area Sq.Mt. - 216.98 153.83 OK
FAR Area Sq.Mt. - 668.79 312.01 OK
Consumed FAR Sq.Mt. - 1.80 0.84 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 18.08 36.11 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 36.11 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.32 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 4 OK
A-1 (RESIDENTIAL) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 7.44 OK
Rear Margin Mt. 1.80 - 1.80 OK
Side1 Margin Mt. 1.00 - 1.23 OK
Side2 Margin Mt. 1.00 - 1.81 OK
A-1 (RESIDENTIAL) BldgLine for 4.8 meter wide road Mt. 0.65 8.09 OK
A-1 (RESIDENTIAL) ResvRoad Width Check for... 4.8 meter wide road Mt. 0.65 0.65 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL) Height Mt. 10.00 6.60 OK
A (RESIDENTIAL) First Floor - Height Mt. 2.75 - 3.30 OK
First Floor - Clear Height Mt. 2.75 - 3.18 OK
First Floor - Beam Clear Height Mt. 2.40 - 3.00 OK
Ground Floor - Height Mt. 2.75 - 3.30 OK
Ground Floor - Clear Height Mt. 2.75 - 3.18 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.00 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (RESIDENTIAL) Terrace Floor - Height Mt. - - 1.00 OK
A (RESIDENTIAL) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 1 OK
A (RESIDENTIAL) FIRST FLOOR PLAN - BALCONY - Width Mt. 1.20 1.20 OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.750 1.067 OK
Staircase -3FL - Tread Width Mt. 0.225 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.100 OK
Staircase -3FL - Riser No. On Flight No. - 8 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.750 1.067 OK
Staircase -3FL - Tread Width Mt. 0.225 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.100 OK
Staircase -3FL - Riser No. On Flight No. - 8 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 1.067 OK
Staircase -3FL - Tread Width Mt. - 0.254 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. 2.100 - 2.675 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.45 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 0.76 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.58 OK
Width Mt. - - 0.23 OK
Depth Mt. - - 6.90 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.45 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 0.76 OK
Height Mt. - - - OK
A (RESIDENTIAL) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
A (RESIDENTIAL) GROUND FLOOR PLAN - PORTICO - Width Mt. 1000000.00 5.00 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Upto 100 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Upto 100 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height In New Area, for plot which lies on road less than 6.10 m. Perm. Building Ht. shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Arch Projection No need to check
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)