No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 24-01-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0057/W09/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameL K Suman
License No.MNAC/ENG/0008/2016
Architect Address2nd Floor, Basant Talkies Complex, Sankchi, Jamshedpur
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1565
NorthSurvey No. - other plot
SouthRoad Width - 5.0
EastSurvey No. - other plot
WestSurvey No. - other plot
Owner's Details
NameMr. Jainath Santosh Porh
AddressKhata No.-552, Plot No.-1565, Thana No.-1642, Mango, Jamshedpur
Email IDabalmuchu@gmail.com
Mobile No8809274167
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 670.00
2 Plot area as per Document by Applicant 636.49
3 Physical area measured at site 636.50
4 Area as per Site Visit (Site Visit Report) 636.49
5Area as per Drawing 636.49

Area of Plot Considered : 636.49

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPROPOSED
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 636.49
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 636.49
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 542.62
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 93.87
93.87
Balance Plot Area 542.62

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 381.89
Proposed Coverage Area ( 30.36 % ) 193.23
Total Prop. Coverage Area ( 30.36 % ) 193.23
Balance coverage area ( 29.64 % ) 188.66
FAR CHECK
Perm. FAR Area ( 1.80 ) 1145.68
Total Perm. FAR area 1145.68
Residential FAR 274.32
Proposed FAR Area 274.32
Total Proposed FAR Area 274.32
Consumed FAR (Factor) 0.43
Balance FAR Area 871.36
BUA CHECK
Total Proposed BuiltUp Area 274.32


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 5 5.00
Proposed Road Width as per Master Plan 5 -
Road Widening Width 0 -
Plot size (as per measurement) 636.49 636.49
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 31.82 93.87 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 24.61 0.00 0.00 - 2.75 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 31.99 0.00 0.00 - 2.41 - 79.70 No Access Provided OK
Tree Cover (Plantation) - 37.27 0.00 0.00 - 2.75 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 10 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (JAINATH SANTOSH PORH) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (JAINATH SANTOSH PORH) 10.00 6.00 6.00 6.30 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (JAINATH SANTOSH PORH) First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.70 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.70 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (JAINATH SANTOSH PORH) Terrace Floor - - 1.10 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (JAINATH SANTOSH PORH) G + 2 2 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
381.89 193.23 OK
60% 30.36%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (JAINATH SANTOSH PORH) - 193.23
  Total Prop. Coverage Area - 193.23
  Total Coverage Area 381.89 193.23

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (JAINATH SANTOSH PORH) 1 274.32 274.32 274.32 274.32 02
Grand Total : 1 274.32 274.32 274.32 274.32 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (JAINATH SANTOSH PORH)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 190.83 190.83 190.83 190.83
First Floor 83.49 83.49 83.49 83.49
Terrace Floor 0.00 0.00 0.00 0.00
Total : 274.32 274.32 274.32 274.32


[-] UnitBUA Table for Building :A (JAINATH SANTOSH PORH)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN A FLAT 190.83 180.48 12 1
FIRST FLOOR PLAN HALL FLAT 83.49 82.68 2 1
Total: - - 274.32 263.16 14 2


[-] Building :A (JAINATH SANTOSH PORH)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 190.83 190.83 190.83 190.83 01
First Floor 83.49 83.49 83.49 83.49 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 274.32 274.32 274.32 274.32 02
Total Number of Same Buildings : 1
Total : 274.32 274.32 274.32 274.32 02
[-] Table 4c-2

  FAR Area
Building FAR Area:274.32
Existing FAR Area :0.00
Perm.
1145.68
Prop.
274.32
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (JAINATH SANTOSH PORH) 5 m wide road 3.00 6.25 1.80 1.84 1.50 2.15 1.50 10.79 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (JAINATH SANTOSH PORH) BldgLine for 5 m wide road 0.05 6.25 5 m wide road 0.05 0.00 Failed





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (JAINATH SANTOSH PORH) Residential Bungalow/ Dwelling / Non Apartment > 0 1 2.00 1.00 2 - - - -
> 0 1 2.00 - - - 1 1 -
Total : - - - - 2 2 - 1 0

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 2 25.00 OK
Total Car 2 25.00 2 25.00 OK
Total Visitor Parking 1 12.50 0 0.00 FAILED
Total 37.50 25.00 FAILED

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PROPOSED - Driveway 3.60 - 5.00 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (JAINATH SANTOSH PORH)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.073 0.225 0.256 0.200 0.136 - 6 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.073 0.225 0.256 0.200 0.136 - 6 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.073 - 0.256 - 0.000 - 0 2.100 - 2.400 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 1.00 - - 1.00 - - 1.00 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.44 - - 0.93 - - 1.56 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (JAINATH SANTOSH PORH) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (JAINATH SANTOSH PORH)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 636.49 OK
  Plot Width - 28.83 OK
  Plot Depth - 22.08 OK
  Access Width - 5.00 OK
  Plot Frontage - 28.83 OK
  Coverage Area 381.89 193.23 OK
  FAR Area
Bldg. FAR Area : 274.32
Sanctioned FAR Area :0.00
1145.68 274.32 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 27-33 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) -
(4) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)