No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 20-09-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0056/W09/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Layout Sanction Date4/7/2005
Architect Details
Architect NameKunal Sinha Mahapatra
License No.MNAC/ENG/0006/2017
Architect AddressG/2, D-Block, D-Choudhury Madusudhan complex, Dimna more, Mango, Jamshedpur
Architect EmailIDkunal.sinha1977@gmail.com
Architect Mobile No9903304812
Plot Details
Plot Use Medical
Plot SubUse Nursing Home
PlotNearbyReligiousStructure NA
Plot/SubPlot No2117, 2118
North -
South -
East -
West -
Owner's Details
NameRANJU KUMARI
AddressFLAT No. 423, UDAYGIRI, ASHIANA ENCLAVE, MANGO, JAMSHEDPUR
Email IDnagendrasingh0089@gmail.com
Mobile No6207898440
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 667.97
2 Plot area as per Document by Applicant 667.97
3 Physical area measured at site 667.97
4 Area as per Site Visit (Site Visit Report) 667.97
5Area as per Drawing 811.16

Area of Plot Considered : 667.97

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyMedical
Plot SubUse Nursing Home
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 667.97
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 667.97
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 572.39
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 95.58
95.58
Balance Plot Area 572.39

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 400.78
Proposed Coverage Area ( 48.99 % ) 327.22
Total Prop. Coverage Area ( 48.99 % ) 327.22
Balance coverage area ( 11.01 % ) 73.56
FAR CHECK
Perm. FAR Area ( 2.500 ) 1669.92
Total Perm. FAR area 1669.92
Special FAR 1639.08
Proposed FAR Area 1653.27
Total Proposed FAR Area 1653.27
Consumed FAR (Factor) 2.48
Balance FAR Area 16.65
BUA CHECK
Total Proposed BuiltUp Area 2079.63


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12.25 12.25
Proposed Road Width as per Master Plan 12.25 -
Road Widening Width 0 -
Plot size (as per measurement) 667.97 811.16
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. 300.00 - 667.97 OK
Plot Width Mt. - - 31.86 OK
Plot Depth Mt. - - 25.46 OK
Access Width Mt. 12.20 - 12.25 OK
Plot Frontage Mt. - - 31.86 OK
Coverage Area Sq.Mt. - 400.78 327.22 OK
FAR Area Sq.Mt. - 1669.92 1653.27 OK
Consumed FAR Sq.Mt. - 2.50 2.48 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 33.40 95.58 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 95.58 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.00 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
A-1 (GANGA MEMORIAL) Front Margin... 12.25 M WIDE ROAD Mt. - - 6.00 OK
Rear Margin Mt. - - 4.50 OK
Side1 Margin Mt. - - 4.50 OK
Side2 Margin Mt. - - 4.50 OK
A-1 (GANGA MEMORIAL) Bsement Front Margin... 12.25 M WIDE ROAD Mt. - - - OK
Basement Rear Margin Mt. - - 4.50 OK
Basement Side1 Margin Mt. - - 4.50 OK
Basement Side2 Margin Mt. - - 4.50 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (GANGA MEMORIAL) Height Mt. 24.38 14.90 OK
A (GANGA MEMORIAL) Fourth Floor - Height Mt. 2.75 - 2.90 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.75 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.45 OK
Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.85 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.85 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.85 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.85 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Basement Floor - Height Mt. 2.40 - 3.00 OK
Basement Floor - Clear Height Mt. 2.40 - 2.85 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.65 OK
A (GANGA MEMORIAL) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (GANGA MEMORIAL) Basement Floor - Height of Basement Floor above GL Mt. 0.90 1.50 1.20 OK
Basement Floor - Area Sq.Mt. - 376.28 OK
Basement Floor - Ventilation Area Sq.Mt. - - OK
A (GANGA MEMORIAL) Area Sq.Mt. - 376.28 OK
Status - OK
Total Area Sq.Mt. - 376.28 OK
A (GANGA MEMORIAL) No. of Basement Floor No. 1 1 OK
A (GANGA MEMORIAL) No. of Floors No. - 5 OK
No. of Tenements No. - 5 OK
A (GANGA MEMORIAL) Number Of Lift(s) No. 1 1 OK
Number Of Strature Lift(s) No. - 1 OK
Capacity Of Lift(s) Passanger No. 6 15 OK
A (GANGA MEMORIAL) BASEMENT FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 1.95 OK
BASEMENT FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.00 OK
THIRD FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 1.95 OK
THIRD FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.00 OK
FOURTH FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 1.95 OK
FOURTH FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.00 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.95 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 3.00 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.000 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.158 OK
Fire Escape Staircase - Riser No. On Flight No. 16 9 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
FOURTH FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.145 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.000 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.153 OK
Fire Escape Staircase - Riser No. On Flight No. 16 9 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.500 OK
STAIRCASE - Tread Width Mt. - 0.300 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.700 OK
Fire Escape Staircase - Flight Width Mt. - 1.000 OK
Fire Escape Staircase - Tread Width Mt. - 0.250 OK
Fire Escape Staircase - Riser Height Mt. - - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - 2.700 OK
Toilet Area Sq.Mt. - 5.00 2.88 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 2.40 OK
Height Mt. - - - OK
RWH Area Sq.Mt. - - 0.82 OK
Width Mt. - - 1.02 OK
Depth Mt. - - 1.02 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.83 OK
Width Mt. - - 0.23 OK
Depth Mt. - - 3.60 OK
Height Mt. - - - OK
SHS Area Sq.Mt. - - 0.82 OK
Width Mt. - - 1.02 OK
Depth Mt. - - 1.02 OK
Height Mt. - - - OK
A (GANGA MEMORIAL) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 12.60 mt. long 1.80 mt. High 3.30 mt. Wide Natural Slope - Width Mt. - 3.30 OK
12.60 mt. long 1.80 mt. High 3.30 mt. Wide Natural Slope - Depth Mt. - 1.80 OK
12.60 mt. long 1.80 mt. High 3.30 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (GANGA MEMORIAL) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Nursing homes/ Polyclinics/ Hospital category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.8 mt. and minimum depth 3.0 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RWH
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SHS
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Hospitals and Nursing Home type of Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)