No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 20-09-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0056/W09/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Layout Sanction Date4/7/2005
Architect Details
Architect NameKunal Sinha Mahapatra
License No.MNAC/ENG/0006/2017
Architect AddressG/2, D-Block, D-Choudhury Madusudhan complex, Dimna more, Mango, Jamshedpur
Architect EmailIDkunal.sinha1977@gmail.com
Architect Mobile No9903304812
Plot Details
Plot Use Medical
Plot SubUse Nursing Home
PlotNearbyReligiousStructure NA
Plot/SubPlot No2117, 2118
North -
South -
East -
West -
Owner's Details
NameRANJU KUMARI
AddressFLAT No. 423, UDAYGIRI, ASHIANA ENCLAVE, MANGO, JAMSHEDPUR
Email IDnagendrasingh0089@gmail.com
Mobile No6207898440
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 667.97
2 Plot area as per Document by Applicant 667.97
3 Physical area measured at site 667.97
4 Area as per Site Visit (Site Visit Report) 667.97
5Area as per Drawing 811.16

Area of Plot Considered : 667.97

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMedical
Plot SubUse Nursing Home
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 667.97
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 667.97
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 572.39
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 95.58
95.58
Balance Plot Area 572.39

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 400.78
Proposed Coverage Area ( 48.99 % ) 327.22
Total Prop. Coverage Area ( 48.99 % ) 327.22
Balance coverage area ( 11.01 % ) 73.56
FAR CHECK
Perm. FAR Area ( 2.500 ) 1669.92
Total Perm. FAR area 1669.92
Special FAR 1639.08
Proposed FAR Area 1653.27
Total Proposed FAR Area 1653.27
Consumed FAR (Factor) 2.48
Balance FAR Area 16.65
BUA CHECK
Total Proposed BuiltUp Area 2079.63


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12.25 12.25
Proposed Road Width as per Master Plan 12.25 -
Road Widening Width 0 -
Plot size (as per measurement) 667.97 811.16
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 33.40 95.58 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 95.58 0.00 0.00 - 3.00 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 8 OK
   
   
   
   
   
    [-] Drawing Checkings

No Rule Status
1 Setback is not checked as per Rule, Please check the Drawing again. Failed

Notice: Please correct the failed entity, you may have the wrong result due to improper drawing.
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (GANGA MEMORIAL) Medical Nursing Home Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (GANGA MEMORIAL) 24.38 14.90 14.90 14.90 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (GANGA MEMORIAL) Fourth Floor 2.75 - 2.90 2.75 - 2.75 2.40 - 2.45 OK
Third Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
Second Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
First Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
Ground Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
Basement Floor 2.40 - 3.00 2.40 - 2.85 2.10 - 2.65 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (GANGA MEMORIAL) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (GANGA MEMORIAL) Basement Floor 0.90 1.50 1.20 - 376.28 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (GANGA MEMORIAL) - 376.28
Total - 376.28 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (GANGA MEMORIAL)   12.25 M WIDE ROAD - 4.50 - 4.50 - 4.50 - 4.50 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (GANGA MEMORIAL) - 5 - 5 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (GANGA MEMORIAL) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
400.78 327.22 OK
60% 48.99%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (GANGA MEMORIAL) - 327.22
  Total Prop. Coverage Area - 327.22
  Total Coverage Area 400.78 327.22

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout StairCase Lift Parking Medical Stair
A (GANGA MEMORIAL) 1 2086.23 6.60 2079.63 1381.46 698.17 40.85 29.25 356.24 983.15 655.93 14.19 1653.29 1653.29 05
Grand Total : 1 2086.23 6.60 2079.63 1381.46 698.17 40.85 29.25 356.24 983.15 655.93 14.19 1653.29 1653.29 05


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (GANGA MEMORIAL)
Proposed Built Up Area (Sq.mt.) Existing Built up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Existing FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total Existing Built up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Existing FAR Area (Sq.mt.)
Basement Floor 14.19 362.09 14.19 0.00 14.19 362.09 14.19 0.00
Ground Floor 0.00 335.39 0.00 327.22 0.00 335.39 0.00 327.22
First Floor 0.00 341.99 0.00 327.97 0.00 341.99 0.00 327.97
Second Floor 0.00 341.99 0.00 327.97 0.00 341.99 0.00 327.97
Third Floor 341.99 0.00 327.97 0.00 341.99 0.00 327.97 0.00
Fourth Floor 341.99 0.00 327.97 0.00 341.99 0.00 327.97 0.00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 698.17 1381.46 670.14 983.15 698.17 1381.46 670.14 983.15


[-] UnitBUA Table for Building :A (GANGA MEMORIAL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type Entity Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN GROUND FLOOR Public Utility Area Existing 299.04 290.57 5 1
FIRST FLOOR PLAN FIRST FLOOR OTHER Existing 306.10 291.16 6 1
SECOND FLOOR PLAN SECOND FLOOR OTHER Existing 284.11 269.16 2 1
THIRD FLOOR PLAN THIRD FLOOR OTHER Proposed 284.11 269.16 2 1
FOURTH FLOOR PLAN FIFTH FLOOR OTHER Proposed 284.11 269.16 2 1
Total: - - - 1457.47 1389.21 17 5


[-] Building :A (GANGA MEMORIAL)
Floor Name Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Parking Medical Stair
Basement Floor 376.28 362.09 14.19 0.00 5.85 356.24 0.00 0.00 14.19 14.19 14.19 00
Ground Floor 335.39 335.39 0.00 8.17 0.00 0.00 327.22 0.00 0.00 327.22 327.22 01
First Floor 341.99 341.99 0.00 8.17 5.85 0.00 327.97 0.00 0.00 327.97 327.97 01
Second Floor 341.99 341.99 0.00 8.17 5.85 0.00 327.97 0.00 0.00 327.97 327.97 01
Third Floor 341.99 0.00 341.99 8.17 5.85 0.00 0.00 327.97 0.00 327.97 327.97 01
Fourth Floor 341.99 0.00 341.99 8.17 5.85 0.00 0.00 327.97 0.00 327.97 327.97 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 2079.63 1381.46 698.17 40.85 29.25 356.24 983.15 655.93 14.19 1653.29 1653.29 05
Total Number of Same Buildings : 1
Total : 2079.63 1381.46 698.17 40.85 29.25 356.24 983.15 655.93 14.19 1653.29 1653.29 05
[-] Table 4c-2

  FAR Area
Building FAR Area:1653.27
Existing FAR Area :0.00
Perm.
1669.92
Prop.
1653.27
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (GANGA MEMORIAL) 12.25 M WIDE ROAD - 6.00 - 4.50 - 4.50 - 4.50 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (GANGA MEMORIAL) 14.90 1 1 - 1 6 15 OK

[-] Lift Check Table

[-] For Building :A (GANGA MEMORIAL)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN STRETCHER LIFT for 15 Person 1.80 1.95 3.00 3.00 OK
THIRD FLOOR PLAN STRETCHER LIFT for 15 Person 1.80 1.95 3.00 3.00 OK
FOURTH FLOOR PLAN STRETCHER LIFT for 15 Person 1.80 1.95 3.00 3.00 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.95 1.90 3.00 OK

   


[-] Parking Details (Table 7)
   
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (GANGA MEMORIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.500 0.250 0.300 0.200 0.000 - 0 - - 0.000 OK
THIRD FLOOR PLAN STAIRCASE 0.900 1.500 0.250 0.300 0.200 0.150 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.000 0.250 0.250 0.200 0.158 16 9 - - 0.000 OK
FOURTH FLOOR PLAN STAIRCASE 0.900 1.500 0.250 0.300 0.200 0.145 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.000 0.250 0.250 0.200 0.153 16 9 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.500 - 0.300 - 0.000 - 0 - - 2.700 OK
Fire Escape Staircase - 1.000 - 0.250 - 0.000 16 0 - - 2.700 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
12.60 mt. long 1.80 mt. High 3.30 mt. Wide Natural Slope - 3.30 - 1.80 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (GANGA MEMORIAL) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 2.88 - - 1.20 - - 2.40 - - 0.00 OK
RWH - - 0.82 - - 1.02 - - 1.02 - - 0.00 OK
ENT.GATE - - 0.83 - - 0.23 - - 3.60 - - 0.00 OK
SHS - - 0.82 - - 1.02 - - 1.02 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (GANGA MEMORIAL) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (GANGA MEMORIAL)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Floor:FIRST FLOOR PLAN



No Room Found.

[-] Floor:SECOND FLOOR PLAN



No Room Found.

[-] Floor:THIRD FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FOURTH FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 300.00 667.97 OK
  Plot Width - 31.86 OK
  Plot Depth - 25.46 OK
  Access Width 12.20 12.25 OK
  Plot Frontage - 31.86 OK
  Coverage Area 400.78 327.22 OK
  FAR Area
Bldg. FAR Area : 1653.27
Sanctioned FAR Area :0.00
1669.92 1653.27 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Nursing homes/ Polyclinics/ Hospital category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.8 mt. and minimum depth 3.0 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RWH
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SHS
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Hospitals and Nursing Home type of Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)