Name |
Description |
Unit |
Reqd |
Perm |
Proposed |
Status |
|
A (MARRIAGE HALL) |
Height |
Mt. |
|
63.38
|
5.73
|
OK
|
|
A (MARRIAGE HALL) |
First Floor - Height |
Mt. |
2.75
|
-
|
2.87
|
OK
|
First Floor - Clear Height |
Mt. |
2.75
|
-
|
2.75
|
OK
|
First Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.41
|
OK
|
Ground Floor - Height |
Mt. |
2.75
|
-
|
2.87
|
OK
|
Ground Floor - Clear Height |
Mt. |
2.75
|
-
|
2.75
|
OK
|
Ground Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.41
|
OK
|
Plinth - Height |
Mt. |
0.45
|
-
|
0.45
|
OK
|
Plinth - Clear Height |
Mt. |
-
|
-
|
0.45
|
OK
|
Plinth - Beam Clear Height |
Mt. |
-
|
-
|
0.45
|
OK
|
|
A (MARRIAGE HALL) |
Terrace Floor - Height |
Mt. |
-
|
-
|
1.07
|
OK
|
Terrace Floor - Clear Height |
Mt. |
-
|
-
|
1.07
|
OK
|
Terrace Floor - Beam Clear Height |
Mt. |
-
|
-
|
1.07
|
OK
|
|
A (MARRIAGE HALL) |
No. of Floors |
No. |
|
-
|
2
|
OK
|
No. of Tenements |
No. |
|
-
|
-
|
OK
|
|
A (MARRIAGE HALL) |
FIRST FLOOR PLAN - Passage Name |
|
|
|
-
|
OK
|
FIRST FLOOR PLAN - Width |
Mt. |
1.00
|
|
1.84
|
OK
|
FIRST FLOOR PLAN - Length |
Mt. |
|
-
|
45.60
|
OK
|
FIRST FLOOR PLAN - Passage Name |
|
|
|
-
|
OK
|
FIRST FLOOR PLAN - Width |
Mt. |
1.00
|
|
1.84
|
OK
|
FIRST FLOOR PLAN - Length |
Mt. |
|
-
|
17.52
|
OK
|
GROUND FLOOR PLAN - Passage Name |
|
|
|
-
|
OK
|
GROUND FLOOR PLAN - Width |
Mt. |
1.00
|
|
1.84
|
OK
|
GROUND FLOOR PLAN - Length |
Mt. |
|
-
|
26.53
|
OK
|
|
A (MARRIAGE HALL) |
Number Of Lift(s) |
No. |
-
|
|
2
|
OK
|
Number Of Strature Lift(s) |
No. |
-
|
|
-
|
OK
|
Capacity Of Lift(s) Passanger |
No. |
-
|
|
12
|
OK
|
|
A (MARRIAGE HALL) |
FIRST FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
FIRST FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
FIRST FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
FIRST FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
GROUND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
GROUND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
GROUND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
GROUND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
|
FIRST FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.750
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.225
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.087
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
Staircase -3FL - Flight Width |
Mt. |
0.750
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.225
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.087
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
TERRACE FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
-
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
-
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
-
|
-
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
2.100
|
-
|
2.492
|
OK
|
Staircase -3FL - Flight Width |
Mt. |
-
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
-
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
-
|
-
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
2.100
|
-
|
2.492
|
OK
|
GROUND FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.750
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.225
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.087
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
Staircase -3FL - Flight Width |
Mt. |
0.750
|
|
1.227
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.225
|
|
0.307
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.087
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
|
Toilet 1.36X3.68 |
Area |
Sq.Mt. |
-
|
5.00
|
5.00
|
OK
|
Width |
Mt. |
-
|
-
|
1.36
|
OK
|
Depth |
Mt. |
-
|
-
|
3.68
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Area |
Sq.Mt. |
-
|
5.00
|
5.00
|
OK
|
Width |
Mt. |
-
|
-
|
1.36
|
OK
|
Depth |
Mt. |
-
|
-
|
3.68
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
SUMP TANK |
Area |
Sq.Mt. |
-
|
-
|
21.29
|
OK
|
Width |
Mt. |
-
|
-
|
3.31
|
OK
|
Depth |
Mt. |
-
|
-
|
6.43
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
RAIN WATER HARVESTING |
Area |
Sq.Mt. |
-
|
-
|
3.63
|
OK
|
Width |
Mt. |
-
|
-
|
2.15
|
OK
|
Depth |
Mt. |
-
|
-
|
2.15
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
ENT.GATE |
Area |
Sq.Mt. |
-
|
-
|
0.68
|
OK
|
Width |
Mt. |
-
|
-
|
0.15
|
OK
|
Depth |
Mt. |
-
|
-
|
4.50
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
SOLAR HEATING SYSTEM |
Area |
Sq.Mt. |
-
|
-
|
38.76
|
OK
|
Width |
Mt. |
-
|
-
|
4.95
|
OK
|
Depth |
Mt. |
-
|
-
|
7.83
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
|
A (MARRIAGE HALL) |
Rain Water Harvesting - No |
No. |
1
|
-
|
1
|
OK
|
Solar Water Heating System - No |
No. |
1
|
-
|
1
|
OK
|
Entrance Gate - No |
No. |
1
|
-
|
1
|
OK
|
|
|
[-] Rules
Topic |
Rule |
Plot Level |
Plot Area |
The minimum size of plot for Marriage Hall category shall be 1000.0 sq.mt. {As per Rule No. 35.1, Table 7}
|
Plot Width |
The minimum size of plot for Marriage Hall category shall be 1000.0 sq.mt. {As per Rule No. 35.1, Table 7}
|
Plot Depth |
The minimum size of plot for Marriage Hall category shall be 1000.0 sq.mt. {As per Rule No. 35.1, Table 7}
|
Access Width |
The minimum width of abutting road for Marriage Hall category shall be 12.20 mt. {As per Rule No. 35.1, Table 7}
|
Plot Frontage |
The minimum size of plot for Marriage Hall category shall be 1000.0 sq.mt. {As per Rule No. 35.1, Table 7}
|
FAR Area |
(1)
For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2)
For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
|
Consumed FAR |
(1)
For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2)
For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
|
Common Plot Area |
In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
|
Common Plot |
(1)
In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2)
;
|
Tree Number |
Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
DriveWay Rule |
For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
|
Building Level |
Building Height |
For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
|
Parapet Height |
(1)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Floor Number |
For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
|
Passage |
No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
|
Lift Count |
(1)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2)
For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
|
Lift |
(1)
The area of lift well shall not be counted for F.A.R calculation)
(2)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3)
-
(4)
The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(5)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4)
; No Rule Defined
|
Plot / Building Level |
Accessory Use |
(1)
Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2)
No need to check distance from Building Toilet 1.36X3.68
(3)
-
(4)
No need to check distance from Building SUMP TANK
(5)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6)
No need to check distance from Building RAIN WATER HARVESTING
(7)
No need to check distance from Building ENT.GATE
(8)
-
(9)
No need to check distance from Building SOLAR HEATING SYSTEM
|
Accessory Use Number |
(1)
Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2)
For Community Centers, Banquet Halls, Barat ghars, Kalayana Mandaps and buildings for similar use, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3)
In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
|