Failed List Report

Mango Municipal Corporation

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 02-08-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/GH/0027/W08/2022
Application TypeGeneral Proposal
Project TypeGroup Development Scheme
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Layout Sanction Date21/9/2019
Architect Details
Architect NameKunal Sinha Mahapatra
License No.MNAC/ENG/0006/2017
Architect AddressG/2, D-Block, D-Choudhury Madusudhan complex, Dimna more, Mango, Jamshedpur
Architect EmailIDkunal.sinha1977@gmail.com
Architect Mobile No9903304812
Plot Details
Plot Use Residential
Plot SubUse Group Housing
PlotNearbyReligiousStructure NA
Plot/SubPlot No3642, 3621
North -
South -
East -
West -
Owner's Details
NameMS SRINATH HOMES INDIA PVT. LTD.
Address112, 1ST FLOOR, ASHIANA TRADE CENTRE, ADITYAPUR, JAMSHEDPUR
Email IDdev12ka4@gmail.com
Mobile No9234686046
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 4575.59
2 Plot area as per Document by Applicant 4575.59
3 Physical area measured at site 4575.59
4 Area as per Site Visit (Site Visit Report) 4575.59
5Area as per Drawing 4575.59

Area of Plot Considered : 4575.59

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Group Housing
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 4575.59
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 4575.59
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 3696.36
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 879.23
879.23
Balance Plot Area 3696.36

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 35.00 % ) 1601.46
Proposed Coverage Area ( 34.53 % ) 1580.12
Total Prop. Coverage Area ( 34.53 % ) 1580.12
Balance coverage area ( 0.47 % ) 21.34
FAR CHECK
Perm. FAR Area ( 2.50 ) 11438.97
Maximum Permissible FAR Area ( 3.00 ) 13726.77
Total Perm. FAR area 13726.77
Residential FAR 13592.93
Commercial FAR 13.50
Special FAR 28.07
Proposed FAR Area 13697.39
Total Proposed FAR Area 13697.39
Consumed FAR (Factor) 2.99
Balance FAR Area 29.38
Total Paid Proposed FAR Area 2258.42
BUA CHECK
Total Proposed BuiltUp Area 19237.77


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 13 13.00
Proposed Road Width as per Master Plan 13 -
Road Widening Width 0 -
Plot size (as per measurement) 4575.59 4575.59
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
LIGEWS Checks EWS Built Up Area - ProvisionForLIGEWS Area 457.56 0.00 Failed
Total - ProvisionForLIGEWS Area 457.56 0 Failed
Total - LIGEWS Unit 51 0 Failed
Total Car In Area Sq.Mt. 1837.50 - 1812.50 Failed

       



[-] Rules
Topic Rule
Plot Level
Plot Area Group Development Scheme is reckoned as development of Residential Buildings in a Campus or Site of 3000 sq.m and above in area and could be row houses, semi-detached, detached Houses, Apartment blocks or High- Rise buildings or mix or combination of the above
Plot Width Group Development Scheme is reckoned as development of Residential Buildings in a Campus or Site of 3000 sq.m and above in area and could be row houses, semi-detached, detached Houses, Apartment blocks or High- Rise buildings or mix or combination of the above
Plot Depth Group Development Scheme is reckoned as development of Residential Buildings in a Campus or Site of 3000 sq.m and above in area and could be row houses, semi-detached, detached Houses, Apartment blocks or High- Rise buildings or mix or combination of the above
Access Width The minimum width of abutting road for Group Housing shall be 6.10 mt.{As per Chapter VI}
Plot Frontage Group Development Scheme is reckoned as development of Residential Buildings in a Campus or Site of 3000 sq.m and above in area and could be row houses, semi-detached, detached Houses, Apartment blocks or High- Rise buildings or mix or combination of the above
FAR Area (1) In Group Housing, the Floor Area Ratio-FAR shall be 3.0 {As per Chapter VI}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
(3) In Group Housing, the Floor Area Ratio-FAR shall be 3.0 {As per Chapter VI}
Consumed FAR (1) In Group Housing, the Floor Area Ratio-FAR shall be 3.0 {As per Chapter VI}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
(3) In Group Housing, the Floor Area Ratio-FAR shall be 3.0 {As per Chapter VI}
ProvisionForLIGEWS Area In all Group Housing and Group Development Scheme Projects, whose land extent is less than 5 acres (2.023 Hectares), the Developer / Builder shall provide 10% of the netplot{As per Rule. No. 61.12 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Multistoried Building, having Building Height 23.10-30.0 mt.,Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 5.0 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For Group Housing, No height limitation shall be applicable except in areas near protected monuments and airport, etc {As per Chapter VI}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) No rule found for Mini. reqd Floor height
(4) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For Group Housing, No floor number limitation shall be applicable {As per Chapter XI}
Balcony Projected balcony may be allowed with a width of 1.2 mt. where the setback is more than 4.5 mt. and 4.5 mt. respectively clear driveway is available for the Fire tender movement {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential building (Apartment and Group Housing) height more then 21.00 mt one stature lift is mandatory.{as per Vth Amendment JBBL 49.1.4 }
Lift (1) -
(2) The area of lift well shall not be counted for F.A.R calculation)
(3) The lift shall have a minimum width 1.8 mt. and minimum depth 3.0 mt.{As per clause no 4 and page no. 14 NBC }
(4) The area of lift well shall not be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(6) ; No Rule Defined
(7) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is more then 40 two ramp of minimum of 3.30m width if it is straight and 3.60m width if it is curved and 5.4m width if one ramp is required shall be provided
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING 3.00 DIA & 3.6 M DEPTH
(3) -
(4) No need to check distance from Building Overhead WaterTank
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Group Housing Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(4) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)