General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0048/W10/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBaliguma
Taluka16
Layout Sanction Date31/12/2012
Architect Details
Architect NameKunal Sinha Mahapatra
License No.MNAC/ENG/0006/2017
Architect AddressG/2, D-Block, D-Choudhury Madusudhan complex, Dimna more, Mango, Jamshedpur
Architect EmailIDkunal.sinha1977@gmail.com
Architect Mobile No9903304812
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No561, 563, 564, 565, 316 (O); 457, a, b (N)
NorthPlot No. - OTHERS PLOT
SouthRoad Width - 7.1
EastPlot No. - OTHERS PLOT
WestRoad Width - 4.5
Owner's Details
NameMs V.L.INFRA
AddressSHOP No. 2, PRIME REGENCY, BALIGUMA, MANGO, JAMSHEDPUR
Email IDmukeshvijaya2001@gmail.com
Mobile No9334893351
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1420.00
2 Plot area as per Document by Applicant 1420.00
3 Physical area measured at site 1420.00
4 Area as per Site Visit (Site Visit Report) 1420.00
5Area as per Drawing 1427.03

Area of Plot Considered : 1420.00

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1420.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1420.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1245.15
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 174.85
174.85
Balance Plot Area 1245.15

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 710.00
Proposed Coverage Area ( 49.32 % ) 700.39
Total Prop. Coverage Area ( 49.32 % ) 700.39
Balance coverage area ( 0.68 % ) 9.61
FAR CHECK
Perm. FAR Area ( 2.500 ) 3550.00
Total Perm. FAR area 3550.00
Residential FAR 2943.91
Commercial FAR 132.14
Proposed FAR Area 3090.36
Total Proposed FAR Area 3090.36
Consumed FAR (Factor) 2.18
Balance FAR Area 459.64
BUA CHECK
Total Proposed BuiltUp Area 3701.55


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7.1 7.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 1420 1427.03
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 142.00 174.85 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 63.02 0.00 0.00 - 4.16 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 111.82 0.00 0.00 - 2.90 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 8 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (VL INFRA) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (VL INFRA) 15.65 15.00 15.00 15.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (VL INFRA) Fourth Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
Third Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
Second Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
First Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
Ground Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (VL INFRA) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (VL INFRA) G + 4 5 - 33 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
710.00 700.39 OK
50% 49.32%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (VL INFRA) - 700.39
  Total Prop. Coverage Area - 700.39
  Total Coverage Area 710.00 700.39

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout StairCase Lift Parking Resi. Stair
A (VL INFRA) 1 3819.10 117.55 3701.55 2516.62 1159.03 47.80 19.00 544.38 1948.75 1127.31 9.56 3090.37 3090.37 33
Grand Total : 1 3819.10 117.55 3701.55 2516.62 1159.03 47.80 19.00 544.38 1948.75 1127.31 9.56 3090.37 3090.37 33


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (VL INFRA)
Proposed Built Up Area (Sq.mt.) Existing Built up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Existing FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total Existing Built up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Existing FAR Area (Sq.mt.)
Ground Floor 14.31 686.08 14.31 132.14 14.31 686.08 14.31 132.14
First Floor 0.00 750.29 0.00 735.98 0.00 750.29 0.00 735.98
Second Floor 0.00 750.29 0.00 735.98 0.00 750.29 0.00 735.98
Third Floor 394.43 329.96 391.33 344.65 394.43 329.96 391.33 344.65
Fourth Floor 750.29 0.00 735.98 0.00 750.29 0.00 735.98 0.00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 1159.03 2516.62 1141.62 1948.75 1159.03 2516.62 1141.62 1948.75


[-] UnitBUA Table for Building :A (VL INFRA)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type Entity Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SHOP SHOP Existing 132.14 116.15 6 1
FIRST FLOOR PLAN UNIT1 FLAT Existing 94.15 83.31 9 8
UNIT2 FLAT Existing 89.15 81.81 9
UNIT3 FLAT Existing 88.72 81.41 9
UNIT4 FLAT Existing 94.15 83.31 9
UNIT5 FLAT Existing 92.13 81.63 9
UNIT6 FLAT Existing 70.91 65.62 8
UNIT7 FLAT Existing 70.91 64.59 8
UNIT8 FLAT Existing 92.13 81.45 9
FOURTH FLOOR PLAN UNIT25 FLAT Proposed 94.15 83.47 9 8
UNIT26 FLAT Proposed 89.15 81.81 9
UNIT27 FLAT Proposed 88.72 81.60 9
UNIT28 FLAT Proposed 94.15 83.57 9
UNIT29 FLAT Proposed 92.13 81.76 9
UNIT30 FLAT Proposed 70.91 65.62 8
UNIT31 FLAT Proposed 70.91 64.59 8
UNIT32 FLAT Proposed 92.13 81.59 9
SECOND FLOOR PLAN UNIT10 FLAT Existing 89.15 81.81 9 8
UNIT11 FLAT Existing 88.72 81.41 9
UNIT12 FLAT Existing 94.15 83.31 9
UNIT13 FLAT Existing 92.13 81.63 9
UNIT14 FLAT Existing 70.91 65.62 8
UNIT15 FLAT Existing 70.91 64.59 8
UNIT16 FLAT Existing 92.13 81.45 9
UNIT9 FLAT Existing 94.15 83.31 9
THIRD FLOOR PLAN UNIT17 FLAT Proposed 94.15 83.43 9 8
UNIT18 FLAT Proposed 89.15 81.81 9
UNIT19 FLAT Existing 88.72 81.41 9
UNIT20 FLAT Existing 94.15 83.31 9
UNIT21 FLAT Existing 92.13 81.63 9
UNIT22 FLAT Existing 70.91 65.62 8
UNIT23 FLAT Proposed 70.91 64.59 8
UNIT24 FLAT Proposed 92.13 81.57 9
Total: - - - 2901.18 2609.79 286 33


[-] Building :A (VL INFRA)
Floor Name Gross Builtup Area Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout StairCase Lift Parking Resi. Stair
Ground Floor 700.39 0.00 700.39 686.08 14.31 9.56 0.00 544.38 132.14 0.00 9.56 146.45 146.45 01
First Floor 779.68 29.39 750.29 750.29 0.00 9.56 4.75 0.00 735.98 0.00 0.00 735.98 735.98 08
Second Floor 779.68 29.39 750.29 750.29 0.00 9.56 4.75 0.00 735.98 0.00 0.00 735.98 735.98 08
Third Floor 779.67 29.38 750.29 329.96 394.43 9.56 4.75 0.00 344.65 391.33 0.00 735.98 735.98 08
Fourth Floor 779.68 29.39 750.29 0.00 750.29 9.56 4.75 0.00 0.00 735.98 0.00 735.98 735.98 08
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 3819.10 44.08 3701.55 2516.62 1159.03 47.80 19.00 544.38 1948.75 1127.31 9.56 3090.37 3090.37 33
Total Number of Same Buildings : 1
Total : 3819.10 44.08 3701.55 2516.62 1159.03 47.80 19.00 544.38 1948.75 1127.31 9.56 3090.37 3090.37 33
[-] Table 4c-2

  FAR Area
Building FAR Area:3090.36
Existing FAR Area :0.00
Perm.
3550.00
Prop.
3090.36
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (VL INFRA) 7.1 M WIDE ROAD 5.00 5.00 4.50 4.55 3.00 3.22 3.00 3.00 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (VL INFRA)
Floor Name Balcony Name Width Status
Perm Prop
FIRST FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
FOURTH FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
SECOND FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
THIRD FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Passage Details

[-] For Building :A (VL INFRA)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
FOURTH FLOOR PLAN 1.53 mt. Wide Passage 28.74 1.00 1.51 - 18.79 OK
THIRD FLOOR PLAN 1.53 mt. Wide Passage 28.74 1.00 1.51 - 18.79 OK

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Status
Prop
A (VL INFRA) 15.00 OK

[-] Lift Check Table

[-] For Building :A (VL INFRA)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN PASSENGER LIFT for 13 Persons 1.90 1.90 2.50 2.50 OK
FOURTH FLOOR PLAN PASSENGER LIFT for 13 Persons 1.90 1.90 2.50 2.50 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.90 1.90 2.50 OK
THIRD FLOOR PLAN PASSENGER LIFT for 13 Persons 1.90 1.90 2.50 2.50 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (VL INFRA) Residential Residential Bldg/Apartment > 0 1 32.00 1.00 32 - - - - - - -
> 0 1 32.00 - - - - - - 1 32 -
> 0 1 32.00 - - - 1 4 - - - -
Total : - - - - 32 38 - 4 4 - 32 35

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 38 475.00 OK
Total Car 32 400.00 38 475.00 OK
Visitor's Car Parking - - 4 50.00 OK
Total Visitor Parking 4 50.00 4 50.00 OK
TwoWheeler - - 35 70.00 OK
Total TwoWheeler 32 64.00 35 70.00 OK
Other Parking - - - 194.38 OK
Total 514.00 859.38 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (VL INFRA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Fire Escape Staircase 0.900 1.220 0.250 0.300 0.200 0.150 16 10 - - 0.000 OK
STAIRCASE 0.900 1.220 0.250 0.300 0.200 0.150 - 10 - - 0.000 OK
FOURTH FLOOR PLAN Fire Escape Staircase 0.900 1.220 0.250 0.300 0.200 0.150 16 10 - - 0.000 OK
STAIRCASE 0.900 1.220 0.250 0.300 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN Fire Escape Staircase - 1.220 - 0.300 - 0.000 16 0 - - 2.700 OK
STAIRCASE - 1.220 - 0.300 - 0.000 - 0 - - 2.700 OK
THIRD FLOOR PLAN Fire Escape Staircase 0.900 1.220 0.250 0.300 0.200 0.150 16 10 - - 0.000 OK
STAIRCASE 0.900 1.220 0.250 0.300 0.200 0.150 - 10 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING 3.00 DIA & 3.6 M DEPTH - - 6.88 - - 2.96 - - 2.96 - - 0.00 OK
ENT.GATE - - 2.50 - - 0.50 - - 5.00 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (VL INFRA) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (VL INFRA)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Floor:FIRST FLOOR PLAN



No Room Found.

[-] Floor:FOURTH FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



No Room Found.

[-] Floor:THIRD FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 1420.00 OK
  Plot Width - 32.76 OK
  Plot Depth - 43.56 OK
  Access Width 6.10 7.10 OK
  Plot Frontage - 34.36 OK
  Coverage Area 710.00 700.39 OK
  FAR Area
Bldg. FAR Area : 3090.36
Sanctioned FAR Area :0.00
3550.00 3090.36 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 39-45 mt. and Plot width 27-33 mt., Margin required in Front shall be 5.0 mt., Rear 4.5 mt. and 3.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
(5) No Rule Defined
(6) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(7) No Rule Defined
(8) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING 3.00 DIA & 3.6 M DEPTH
(3) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)