No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 21-04-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0040/W09/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameL K Suman
License No.MNAC/ENG/0008/2016
Architect Address2nd Floor, Basant Talkies Complex, Sankchi, Jamshedpur
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1738
NorthSurvey No. - other plot
SouthSurvey No. - other pot
EastSurvey No. - other plot
WestRoad Width - 6.11
Owner's Details
NameSmt. Shanti Devi
AddressH. No.-31999, Hill View Colony, Road No.-4, Dimna Road Mango Jsr.
Email IDtirupatinathk@gmail.com
Mobile No9431185421
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 195.17
2 Plot area as per Document by Applicant 195.16
3 Physical area measured at site 195.16
4 Area as per Site Visit (Site Visit Report) 195.16
5Area as per Drawing 195.16

Area of Plot Considered : 195.16

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
Plotplot
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 195.16
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 195.16
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 177.66
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 17.50
17.50
Balance Plot Area 177.66

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 136.61
Proposed Coverage Area ( 61.31 % ) 119.66
Total Prop. Coverage Area ( 61.31 % ) 119.66
Balance coverage area ( 8.69 % ) 16.95
FAR CHECK
Perm. FAR Area ( 2.500 ) 487.90
Total Perm. FAR area 487.90
Residential FAR 305.28
Proposed FAR Area 305.28
Total Proposed FAR Area 305.28
Consumed FAR (Factor) 1.56
Balance FAR Area 182.62
BUA CHECK
Total Proposed BuiltUp Area 366.97


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 5.95 6.11
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 195.16 195.16

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 9.76 17.50 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 17.50 0.00 0.00 - 1.67 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 9 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SHANTI DEVI) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SHANTI DEVI) 12.16 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SHANTI DEVI) Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.70 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.70 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.70 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SHANTI DEVI) Terrace Floor - - 1.10 - - 1.10 - - 1.10 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SHANTI DEVI) G + 4 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
136.61 119.66 OK
70% 61.31%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SHANTI DEVI) - 119.66
  Total Prop. Coverage Area - 119.66
  Total Coverage Area 136.61 119.66

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Resi.
A (SHANTI DEVI) 1 366.97 6.46 3.99 51.24 305.28 305.28 305.28 01
Grand Total : 1 366.97 6.46 3.99 51.24 305.28 305.28 305.28 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SHANTI DEVI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 119.67 68.43 119.67 68.43
First Floor 119.66 116.43 119.66 116.43
Second Floor 127.64 120.42 127.64 120.42
Terrace Floor 0.00 0.00 0.00 0.00
Total : 366.97 305.28 366.97 305.28


[-] UnitBUA Table for Building :A (SHANTI DEVI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT a FLAT 306.05 296.39 5 1
FIRST FLOOR PLAN SPLIT a FLAT 0.00 0.00 11 0
SECOND FLOOR PLAN SPLIT a FLAT 0.00 0.00 8 0
Total: - - 306.05 296.39 24 1


[-] Building :A (SHANTI DEVI)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Resi.
Ground Floor 119.67 0.00 0.00 51.24 68.43 68.43 68.43 01
First Floor 119.66 3.23 0.00 0.00 116.43 116.43 116.43 00
Second Floor 127.64 3.23 3.99 0.00 120.42 120.42 120.42 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 366.97 6.46 3.99 51.24 305.28 305.28 305.28 01
Total Number of Same Buildings : 1
Total : 366.97 6.46 3.99 51.24 305.28 305.28 305.28 01
[-] Table 4c-2

  FAR Area
Building FAR Area:305.28
Existing FAR Area :0.00
Perm.
487.90
Prop.
305.28
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SHANTI DEVI) 6.11 M WIDE ROAD 2.50 3.00 1.50 1.80 0.90 0.90 0.90 0.90 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (SHANTI DEVI)
Floor Name Balcony Name Width Status
Perm Prop
SECOND FLOOR PLAN BALCONY 1.20 0.90 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (SHANTI DEVI) 9.00 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (SHANTI DEVI)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.93 1.90 2.36 OK
GROUND FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
FIRST FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
SECOND FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK

   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (SHANTI DEVI)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SHANTI DEVI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
TERRACE FLOOR PLAN STAIRCASE - 1.073 - 0.268 - 0.000 - 0 - - 2.400 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.073 0.250 0.268 0.200 0.136 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.073 0.250 0.268 0.200 0.136 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.073 0.250 0.268 0.200 0.136 - 10 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 2.92 - - 1.37 - - 2.13 - - 0.00 OK
ENT.GATE - - 1.04 - - 0.23 - - 4.50 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.92 - - 1.37 - - 2.13 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SHANTI DEVI) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SHANTI DEVI)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 195.16 OK
  Plot Width - 10.67 OK
  Plot Depth - 18.29 OK
  Access Width - 6.11 OK
  Plot Frontage - 10.67 OK
  Coverage Area 136.61 119.66 OK
  FAR Area
Bldg. FAR Area : 305.28
Sanctioned FAR Area :0.00
487.90 305.28 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) -
(2) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(4) The area of lift well shall not be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)