No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 14-05-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0095/W09/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Layout Sanction Date29/1/2009
Architect Details
Architect NameAWDHESH PRASAD
License No.MNAC/ARC/0009/2021
Architect AddressAWDHESH PRASAD, S/O- SRIKANT PRASAD, FLAT NO - H/2, SHIV KUMAR ASTHALI , PHASE II, BLOCK B
Architect EmailIDawdhesh.prasad@gmail.com
Architect Mobile No8404962518
Plot Details
Plot Use Educational
Plot SubUse School
PlotNearbyReligiousStructure NA
Plot/SubPlot No678,679,680
NorthRoad Width - 190.85
SouthRoad Width - 128.95
EastRoad Width - 172.89
WestRoad Width - 193.04
Owner's Details
NameSHARATCHANDRAN NAIR
AddressKERALA PUBLIC SCHOOL, JAWAHARNAGAR, MANGO, JAMSHEDPUR, EAST SINGHBHUM
Email IDkpsdirector.ecaw@gmail.com
Mobile No9431133895
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 28738.50
2 Physical area measured at site 28738.50
3 Area as per Site Visit (Site Visit Report) 28738.50
4Area as per Drawing 28738.50

Area of Plot Considered : 28738.50

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotKERALA PUBLIC SCHOOL -PLOT NO 678,679,680PLOT AREA - 28738.50 sqm
Plot OccupancyEducational
Plot SubUse School
Building StructureMultistoried
Building TypeSpecial Building
Gross Plot Area 28738.50
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 28738.50
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 25764.40
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 2974.10
2974.10
Balance Plot Area 25764.40

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 14369.25
Proposed Coverage Area ( 1.78 % ) 510.21
Existing Building Coverage area ( 14.97 % ) 4301.04
Total Prop. Coverage Area ( 16.74 % ) 4811.25
Balance coverage area ( 33.26 % ) 9558.00
FAR CHECK
Perm. FAR Area ( 2.250 ) 64661.63
Total Perm. FAR area 64661.63
Special FAR 1886.17
Proposed FAR Area 1886.17
Existing Building FAR Area 17205.85
Total Proposed FAR Area 19092.02
Consumed FAR (Factor) 0.66
Balance FAR Area 45569.61
BUA CHECK
Proposed BuiltUp Area 2152.22
Existing Building BUA Area 17205.85
Total Proposed BuiltUp Area 19358.07


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 18 18.00
Proposed Road Width as per Master Plan 18 -
Road Widening Width 3 -
Plot size (as per measurement) 28738.5 28738.50


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 2873.85 2974.10 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 185.70 0.00 0.00 - 5.48 - 90.00 No Access Provided OK
PlayGrounds - 2788.40 0.00 0.00 - 26.95 - 87.97 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 18 OK
   
   
   
   
   
     
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (AUDITORIUM WITH CLASSROOM) Educational School Multistoried
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (AUDITORIUM WITH CLASSROOM) 30.00 16.80 16.80 16.80 OK


[-] Total Existing Building Height
Building Height Status
Perm Prop
Sanctioned/BPS Structure-3 30.00 13.80 OK
Sanctioned/BPS Structure-2 30.00 13.80 OK
Sanctioned/BPS Structure-1 30.00 13.00 OK

   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (AUDITORIUM WITH CLASSROOM) Third Floor 3.30 - 6.00 3.30 - 3.30 2.40 - 3.30 OK
Second Floor 3.30 - 3.60 3.30 - 3.30 2.40 - 3.30 OK
First Floor 3.30 - 3.60 3.30 - 3.30 2.40 - 3.30 OK
Ground Floor 3.30 - 3.60 3.30 - 3.30 2.40 - 3.30 OK
Basement Floor 2.40 - 3.60 2.40 - 3.45 2.10 - 3.30 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (AUDITORIUM WITH CLASSROOM) Terrace Floor - - 0.30 - - 0.30 - - 0.30 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (AUDITORIUM WITH CLASSROOM) Basement Floor 0.90 1.50 0.90 - 249.07 - 2.21 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (AUDITORIUM WITH CLASSROOM) - 249.07
Total - 249.07 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (AUDITORIUM WITH CLASSROOM)   18 M WIDE MAINROAD 9.00 142.39 6.00 6.12 6.00 6.21 6.00 153.82 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (AUDITORIUM WITH CLASSROOM) - 4 - 5 OK


[-] Floor Number Check (For Existing Building)
Building Name No. of Floors Status
Perm Prop
Sanctioned/BPS Structure-3 - 4 OK
Sanctioned/BPS Structure-2 - 4 OK
Sanctioned/BPS Structure-1 - 4 OK
 

[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (AUDITORIUM WITH CLASSROOM) 2 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
14369.25 4811.25 OK
50% 16.74%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (AUDITORIUM WITH CLASSROOM) - 510.21
  Total Prop. Coverage Area - 510.21
  Existing Coverage Area - 4301.04
  Total Coverage Area 14369.25 4811.25

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Educational
A (AUDITORIUM WITH CLASSROOM) 1 2152.22 16.99 1886.17 1886.16 1886.16 05
Grand Total : 1 2152.22 16.99 1886.17 1886.16 1886.16 05


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (AUDITORIUM WITH CLASSROOM)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 249.07 0.00 249.07 0.00
Ground Floor 510.21 493.22 510.21 493.22
First Floor 449.60 449.60 449.60 449.60
Second Floor 449.60 449.60 449.60 449.60
Third Floor 493.74 493.74 493.74 493.74
Terrace Floor 0.00 0.00 0.00 0.00
Total : 2152.22 1886.16 2152.22 1886.16


[-] UnitBUA Table for Building :A (AUDITORIUM WITH CLASSROOM)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN GF - 510.21 OTHER 490.37 459.99 7 1
FIRST FLOOR PLAN 1F - 449.60 OTHER 447.72 437.63 9 1
SECOND FLOOR PLAN 2F - 449.60 OTHER 447.72 437.63 9 1
THIRD FLOOR PLAN 3F - 493.74 OTHER 493.74 465.94 8 1
BASEMENT FLOOR PLAN B'MENT- 249.07 OTHER 249.07 227.30 5 1
Total: - - 2128.62 2028.49 38 5


[-] Building :A (AUDITORIUM WITH CLASSROOM)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Educational
Basement Floor 249.07 0.00 0.00 0.00 0.00 01
Ground Floor 510.21 16.99 493.22 493.22 493.22 01
First Floor 449.60 0.00 449.60 449.60 449.60 01
Second Floor 449.60 0.00 449.60 449.60 449.60 01
Third Floor 493.74 0.00 493.74 493.74 493.74 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 2152.22 16.99 1886.17 1886.16 1886.16 05
Total Number of Same Buildings : 1
Total : 2152.22 16.99 1886.17 1886.16 1886.16 05




[-] Table 4c-2

  FAR Area
Building FAR Area:1886.17
Existing FAR Area :17205.85
Perm.
64661.63
Prop.
19092.02
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (AUDITORIUM WITH CLASSROOM) 18 M WIDE MAINROAD 9.00 135.35 6.00 6.12 6.00 6.05 6.00 145.70 OK


[-] Plot Margin (Table 5b)
Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
Sanctioned/BPS Structure-1 18 M WIDE MAINROAD 9.00 90.64 6.00 28.75 - - - - OK
Sanctioned/BPS Structure-2 18 M WIDE MAINROAD 9.00 26.28 6.00 74.50 - - - - OK
Sanctioned/BPS Structure-3 18 M WIDE MAINROAD 9.00 114.99 6.00 37.94 - - - - OK



[-] Building To Building Margin Check (Table 5b)
From Wing To Wing Margin Status
Reqd Prop
A-1 (AUDITORIUM WITH CLASSROOM) Sanctioned/BPS Structure-2 9.00 36.31 OK






[-] Inner Building Details (Table 6)
   
   
[-] Passage Details

[-] For Building :A (AUDITORIUM WITH CLASSROOM)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
GROUND FLOOR PLAN 2.30 mt. Wide Passage 57.57 1.00 2.30 - 25.03 OK
FIRST FLOOR PLAN 2.30 mt. Wide Passage 57.48 1.00 2.30 - 24.99 OK
SECOND FLOOR PLAN 2.30 mt. Wide Passage 57.48 1.00 2.30 - 24.99 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car
Reqd. Prop. Reqd./Unit Reqd. Prop.
A (AUDITORIUM WITH CLASSROOM) Educational Educational Building > 0 70 - 1 - -
> 0 70 - - - -
Total : - - - - 0 0

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Total 0.00 0.00 OK


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (AUDITORIUM WITH CLASSROOM)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.500 0.250 1.405 0.200 0.144 - 2 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.500 0.250 1.405 0.200 0.144 - 2 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.500 0.250 1.405 0.200 0.144 - 2 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.500 - 0.300 - 0.000 - 0 - - 2.400 OK
THIRD FLOOR PLAN STAIRCASE 0.900 1.500 0.250 0.300 0.200 0.188 - 5 - - 0.000 OK
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.500 0.250 1.405 0.200 0.000 - 0 - - 0.000 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (AUDITORIUM WITH CLASSROOM)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
GROUND FLOOR PLAN CHHAJJA 0.75 0.75 - 21.69 - 16.27 OK
CHHAJJA 0.75 0.75 - 6.70 - 5.03 OK
CHHAJJA 0.75 0.75 - 8.65 - 6.49 OK
CHHAJJA 0.75 0.75 - 1.66 - 1.25 OK
CHHAJJA 0.75 0.75 - 7.46 - 5.60 OK
FIRST FLOOR PLAN CHHAJJA 0.75 0.75 - 21.69 - 16.27 OK
CHHAJJA 0.75 0.75 - 6.70 - 5.03 OK
CHHAJJA 0.75 0.75 - 8.65 - 6.49 OK
CHHAJJA 0.75 0.75 - 1.66 - 1.25 OK
CHHAJJA 0.75 0.75 - 7.46 - 5.60 OK
SECOND FLOOR PLAN CHHAJJA 0.75 0.75 - 21.69 - 16.27 OK
CHHAJJA 0.75 0.75 - 6.70 - 5.03 OK
CHHAJJA 0.75 0.75 - 8.65 - 6.49 OK
CHHAJJA 0.75 0.75 - 1.66 - 1.25 OK
CHHAJJA 0.75 0.75 - 11.64 - 8.73 OK
TERRACE FLOOR PLAN CHHAJJA 0.75 0.75 - 1.66 - 1.25 OK
THIRD FLOOR PLAN CHHAJJA 0.75 0.75 - 6.70 - 5.03 OK
CHHAJJA 0.75 0.75 - 3.47 - 2.60 OK
CHHAJJA 0.75 0.75 - 4.73 - 3.55 OK
CHHAJJA 0.75 0.75 - 1.66 - 1.25 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 5.00 - - 2.00 - - 2.50 - - 0.00 OK
RAIN WATER HARVESTING - - 7.06 - - 2.99 - - 3.00 - - 0.00 OK
Overhead WaterTank - - 10.92 - - 3.30 - - 3.31 - - 0.00 OK
ENT.GATE 1 - - 6.02 - - 1.00 - - 6.03 - - 0.00 OK
ENT.GATE 2 - - 6.01 - - 1.00 - - 6.01 - - 0.00 OK
ENT.GATE 3 - - 6.00 - - 1.00 - - 6.00 - - 0.00 OK
EntranceLobby - 12.00 11.99 - - 1.73 - - 6.93 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (AUDITORIUM WITH CLASSROOM) Rain Water Harvesting 1 - 1 OK
Toilet 1 - 1 OK
Entrance Gate 1 - 3 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (AUDITORIUM WITH CLASSROOM)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:THIRD FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:BASEMENT FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 2000.00 28738.50 OK
  Plot Width - 159.98 OK
  Plot Depth - 179.64 OK
  Access Width 9.00 18.00 OK
  Plot Frontage - 128.95 OK
  Coverage Area 14369.25 4811.25 OK
  FAR Area
Bldg. FAR Area : 1886.17
Sanctioned FAR Area :17205.85
64661.63 19092.02 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Primary/Upper Primary school category shall be 2000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for Primary/Upper Primary school category shall be 2000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for Primary/Upper Primary school category shall be 2000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for Primary/Upper Primary school category shall be 9.0 mt. {As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Primary/Upper Primary school category shall be 2000.0 sq.mt. {As per Rule No. 35.1, Table 7}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) No Rule Define.
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) No Rule Define.
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Educational Building, Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.1}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
(2) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building Overhead WaterTank
(7) No need to check distance from Building ENT.GATE 1
(8) No need to check distance from Building ENT.GATE 2
(9) No need to check distance from Building ENT.GATE 3
(10) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(11) No need to check distance from Building EntranceLobby
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
--- End ---