No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 28-10-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0076/W09/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDimna
Taluka16
Architect Details
Architect NameGAURI SHANKAR SAHU
License No.MNAC/ENG/0025/2017
Architect AddressS-1, BLOCK-13, KRISHNA APARTMENT, ALOK VIHAR , GHORA BANDHA, TELCO, JAMSHEDPUR
Architect EmailIDgssahu7@gmail.com
Architect Mobile No7209935036
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1882
NorthRoad Width - 9.5m Wide Road
SouthPlot No. - Other Plot
EastRoad Width - 6.10 Wide Road
WestPlot No. - Other Plot
Owner's Details
NameSHREEMADHAV CONSTRUCTION
AddressDIMNA BASTI NEAR SHIV MANDIR MANGO JAMSHEDPUR EAST SINGHBHUM 831012
Email IDarunsinha49@gmail.com
Mobile No9431755568
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1457.39
2 Plot area as per Document by Applicant 1456.68
3 Physical area measured at site 1456.68
4 Area as per Site Visit (Site Visit Report) 1456.68
5Area as per Drawing 1456.68

Area of Plot Considered : 1456.68

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 1456.68
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1456.68
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1302.81
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 153.87
153.87
Balance Plot Area 1302.81

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 728.34
Proposed Coverage Area ( 49.98 % ) 727.99
Total Prop. Coverage Area ( 49.98 % ) 727.99
Balance coverage area ( 0.02 % ) 0.35
FAR CHECK
Perm. FAR Area ( 2.500 ) 3641.70
Total Perm. FAR area 3641.70
Residential FAR 3333.56
Proposed FAR Area 3375.43
Total Proposed FAR Area 3375.43
Consumed FAR (Factor) 2.32
Balance FAR Area 266.27
BUA CHECK
Total Proposed BuiltUp Area 4532.69


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7.7 7.70
Proposed Road Width as per Master Plan 7.7 -
Road Widening Width 0 -
Plot size (as per measurement) 1456.68 1456.68
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 145.67 153.87 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 57.54 0.00 0.00 - 3.54 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 96.33 0.00 0.00 - 2.79 - 86.65 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 21 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SHREE MADHAV CONSTRUCTION) Residential Residential Bldg/Apartment Multistoried
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SHREE MADHAV CONSTRUCTION) 18.06 18.00 18.00 18.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SHREE MADHAV CONSTRUCTION) Fifth Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.55 OK
Fourth Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.55 OK
Third Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.55 OK
Second Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.55 OK
First Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.55 OK
Ground Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.55 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SHREE MADHAV CONSTRUCTION) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SHREE MADHAV CONSTRUCTION) G + 5 6 - 35 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
728.34 727.99 OK
50% 49.98%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SHREE MADHAV CONSTRUCTION) - 727.99
  Total Prop. Coverage Area - 727.99
  Total Coverage Area 728.34 727.99

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Balcony Void Accessory Use Parking Resi. Stair
A (SHREE MADHAV CONSTRUCTION) 1 4532.69 69.60 48.45 59.64 38.35 255.10 686.12 3333.56 32.18 3375.43 3375.43 35
Grand Total : 1 4532.69 69.60 48.45 59.64 38.35 255.10 686.12 3333.56 32.18 3375.43 3375.43 35


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SHREE MADHAV CONSTRUCTION)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 727.99 41.87 727.99 41.87
First Floor 705.22 622.92 705.22 622.92
Second Floor 774.87 677.66 774.87 677.66
Third Floor 774.87 677.66 774.87 677.66
Fourth Floor 774.87 677.66 774.87 677.66
Fifth Floor 774.87 677.66 774.87 677.66
Terrace Floor 0.00 0.00 0.00 0.00
Total : 4532.69 3375.43 4532.69 3375.43


[-] UnitBUA Table for Building :A (SHREE MADHAV CONSTRUCTION)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN UNIT-1 FLAT 90.49 90.32 11 7
UNIT-2 FLAT 92.05 91.90 11
UNIT-3 FLAT 60.57 60.44 7
UNIT-4 FLAT 80.30 80.12 10
UNIT-5 FLAT 62.43 62.35 8
UNIT-6 FLAT 87.03 86.89 10
UNIT-7 FLAT 86.57 86.50 10
TYPICAL - 2, 3, 4& 5 FLOOR PLAN UNIT-10 FLAT 69.04 68.99 8 28
UNIT-11 FLAT 80.31 80.16 9
UNIT-12 FLAT 61.73 61.63 7
UNIT-13 FLAT 96.22 96.09 10
UNIT-14 FLAT 95.77 95.59 10
UNIT-8 FLAT 98.87 98.65 11
UNIT-9 FLAT 99.64 99.57 11
Total: - - 2965.72 2961.27 331 35


[-] Building :A (SHREE MADHAV CONSTRUCTION)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Balcony Void Accessory Use Parking Resi. Stair
Ground Floor 727.99 0.00 0.00 0.00 0.00 0.00 686.12 0.00 32.18 41.87 41.87 00
First Floor 705.22 13.92 9.69 0.00 7.67 51.02 0.00 622.92 0.00 622.92 622.92 07
Second Floor 774.87 13.92 9.69 14.91 7.67 51.02 0.00 677.66 0.00 677.66 677.66 07
Third Floor 774.87 13.92 9.69 14.91 7.67 51.02 0.00 677.66 0.00 677.66 677.66 07
Fourth Floor 774.87 13.92 9.69 14.91 7.67 51.02 0.00 677.66 0.00 677.66 677.66 07
Fifth Floor 774.87 13.92 9.69 14.91 7.67 51.02 0.00 677.66 0.00 677.66 677.66 07
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 4532.69 69.60 48.45 59.64 38.35 255.10 686.12 3333.56 32.18 3375.43 3375.43 35
Total Number of Same Buildings : 1
Total : 4532.69 69.60 48.45 59.64 38.35 255.10 686.12 3333.56 32.18 3375.43 3375.43 35
[-] Table 4c-2

  FAR Area
Building FAR Area:3375.43
Existing FAR Area :0.00
Perm.
3641.70
Prop.
3375.43
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SHREE MADHAV CONSTRUCTION) 7.70 mt. Wide MainRoad 6.50 6.51 4.50 4.50 4.50 4.50 4.50 4.50 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (SHREE MADHAV CONSTRUCTION)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 2, 3, 4& 5 FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (SHREE MADHAV CONSTRUCTION) 18.00 3 2 - 0 18 12 Failed

[-] Lift Check Table

[-] For Building :A (SHREE MADHAV CONSTRUCTION)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
FIRST FLOOR PLAN Lift 1.70 2.13 1.90 2.28 OK
Lift 1.70 2.13 1.90 2.28 OK
TYPICAL - 2, 3, 4& 5 FLOOR PLAN Lift 1.70 2.13 1.90 2.28 OK
Lift 1.70 2.13 1.90 2.28 OK
GROUND FLOOR PLAN Lift 1.70 2.13 1.90 2.28 OK
Lift 1.70 2.13 1.90 2.28 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 2.13 1.90 2.28 OK
Lift Machine Room 1.70 2.13 1.90 2.28 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SHREE MADHAV CONSTRUCTION) Residential Residential Bldg/Apartment > 0 1 35.00 1.00 35 - - - - - - -
> 0 1 35.00 - - - - - - 1 35 -
> 0 1 35.00 - - - 1 4 - - - -
Total : - - - - 35 35 - 4 4 - 35 36

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 31 387.50 OK
Two Stack.Car - - 4 50.00 OK
Total Car 35 437.50 35 437.50 OK
Visitor's Car Parking - - 4 50.00 OK
Total Visitor Parking 4 50.00 4 50.00 OK
TwoWheeler - - 36 72.00 OK
Total TwoWheeler 35 70.00 36 72.00 OK
Other Parking - - - 251.62 OK
Total 557.50 883.12 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - 3.0M DRIVE WAY 3.00 - 3.00 OK
A (SHREE MADHAV CONSTRUCTION) GROUND FLOOR PLAN 3.60 M DRIVE WAY 3.60 - 3.60 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SHREE MADHAV CONSTRUCTION)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
FIRST FLOOR PLAN STAIRCASE 0.900 1.370 0.250 0.300 0.200 0.150 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.370 0.250 0.300 0.200 0.150 16 10 - - 0.000 OK
TYPICAL - 2, 3, 4& 5 FLOOR PLAN STAIRCASE 0.900 1.370 0.250 0.300 0.200 0.150 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.370 0.250 0.300 0.200 0.150 16 10 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.370 0.250 0.300 0.200 0.150 - 10 - - 0.000 OK
STAIRCASE 0.900 1.370 0.250 0.300 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.370 - 0.300 - 0.000 - 0 - - 2.500 OK
Fire Escape Staircase - 1.370 - 0.300 - 0.000 16 0 - - 2.500 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 3.50 - - 1.50 - - 2.33 - - 0.00 OK
RAIN WATER HARVESTING - - 9.51 - - 2.64 - - 3.60 - - 0.00 OK
ENT.GATE - - 0.28 - - 0.12 - - 2.44 - - 0.00 OK
GUARD ROOM - 10.00 3.34 - - 1.00 - - 3.34 - - 0.00 OK
Entrance Lobby - 12.00 8.59 - - 2.74 - - 3.14 - - 0.00 OK
Entrance Lobby - 12.00 10.63 - - 2.74 - - 3.92 - - 0.00 OK
Entrance Lobby - 12.00 7.56 - - 1.83 - - 4.13 - - 0.00 OK
Entrance Lobby - 12.00 7.56 - - 1.83 - - 4.13 - - 0.00 OK
Entrance Lobby - 12.00 7.56 - - 1.83 - - 4.13 - - 0.00 OK
Entrance Lobby - 12.00 9.11 - - 1.83 - - 4.98 - - 0.00 OK
Entrance Lobby - 12.00 8.59 - - 2.74 - - 3.14 - - 0.00 OK
Entrance Lobby - 12.00 10.63 - - 2.74 - - 3.92 - - 0.00 OK
Entrance Lobby - 12.00 7.56 - - 1.83 - - 4.13 - - 0.00 OK
Entrance Lobby - 12.00 7.56 - - 1.83 - - 4.13 - - 0.00 OK
Entrance Lobby - 12.00 7.56 - - 1.83 - - 4.13 - - 0.00 OK
Entrance Lobby - 12.00 9.11 - - 1.83 - - 4.98 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SHREE MADHAV CONSTRUCTION) Rain Water Harvesting 1 - 1 OK
Toilet 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SHREE MADHAV CONSTRUCTION)


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 2, 3, 4& 5 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:GROUND FLOOR PLAN



No Room Found.



   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 1456.68 OK
  Plot Width - 24.17 OK
  Plot Depth - 60.27 OK
  Access Width 6.10 7.70 OK
  Plot Frontage - 25.60 OK
  Coverage Area 728.34 727.99 OK
  FAR Area
Bldg. FAR Area : 3375.43
Sanctioned FAR Area :0.00
3641.70 3375.43 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
(2) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Multistoried Building, having Building Height 16.40-19.25 mt.,Margin required in Front shall be 6.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a width of 1.2 mt. where the setback is more than 4.5 mt. and 4.5 mt. respectively clear driveway is available for the Fire tender movement {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, above G+4 floors or if the number of flats is 16 or more, Mini. 1 Lift shall be required For every 16 flats or part thereof. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(7) No need to check distance from Building GUARD ROOM
(8) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(9) No need to check distance from Building Entrance Lobby
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)