-
No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 21-11-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0084/W10/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameChandrika Sharma
License No.MNAC/DFTMN/0017/2017
Architect AddressShop no-4, Geetanjali Madhusudan Complex, Dimna Road, Mango, Jamshedpur
Architect EmailIDcksharma6651@gmail.com
Architect Mobile No9504973852
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No3933
NorthRoad Width - 4.26
SouthPlot No. - 3932
EastPlot No. - 3933
WestPlot No. - 3929
Owner's Details
NameMR. DILIP KUMAR PRASAD S.O SRI RAMKISHUN SAW AND MRS. ARTI PRASAD W.O MR. DILIP KUMAR PRASAD
AddressBALESHWAR PATH, DIMNA ROAD, MANGO, JAMSHEDPUR, JHARKHAND
Email IDprabhatconsultant6651@gmail.com
Mobile No9431386394
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 134.20
2 Plot area as per Document by Applicant 133.40
3 Physical area measured at site 133.40
4 Area as per Site Visit (Site Visit Report) 133.40
5Area as per Drawing 133.40

Area of Plot Considered : 133.40

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 133.40
Deduction from Gross Plot area
- Surrender Free of Cost 2.90
2.90
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 130.50
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 103.73
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 2.90
- Common Plot 26.77
29.67
Balance Plot Area 103.73

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 91.35
Proposed Coverage Area ( 55.89 % ) 72.94
Total Prop. Coverage Area ( 55.89 % ) 72.94
Balance coverage area ( 14.11 % ) 18.41
FAR CHECK
Perm. FAR Area ( 1.500 ) 200.10
Total Perm. FAR area 200.10
Residential FAR 130.05
Proposed FAR Area 139.46
Total Proposed FAR Area 139.46
Consumed FAR (Factor) 1.05
Balance FAR Area 60.64
BUA CHECK
Total Proposed BuiltUp Area 202.98


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.26 4.26
Proposed Road Width as per Master Plan 4.26 -
Road Widening Width 0.5 0.50
Plot size (as per measurement) 133.4 133.40
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 6.53 26.77 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 26.77 0.00 0.00 - 4.61 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENTIAL) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENTIAL) 9.89 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Second Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.70 OK
First Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.70 OK
Ground Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.70 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENTIAL) G + 2 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
91.35 72.94 OK
70% 55.89%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENTIAL) - 72.94
  Total Prop. Coverage Area - 72.94
  Total Coverage Area 91.35 72.94

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
A (RESIDENTIAL) 1 202.98 63.52 130.05 9.41 139.46 139.46 01
Grand Total : 1 202.98 63.52 130.05 9.41 139.46 139.46 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENTIAL)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 72.93 9.41 72.93 9.41
First Floor 72.94 72.94 72.94 72.94
Second Floor 57.11 57.11 57.11 57.11
Terrace Floor 0.00 0.00 0.00 0.00
Total : 202.98 139.46 202.98 139.46


[-] UnitBUA Table for Building :A (RESIDENTIAL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN SPLIT BUNGALOW FLAT 91.26 87.91 6 1
SECOND FLOOR PLAN SPLIT BUNGALOW FLAT 0.00 0.00 5 0
Total: - - 91.26 87.91 11 1


[-] Building :A (RESIDENTIAL)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
Ground Floor 72.93 63.52 0.00 9.41 9.41 9.41 00
First Floor 72.94 0.00 72.94 0.00 72.94 72.94 01
Second Floor 57.11 0.00 57.11 0.00 57.11 57.11 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 202.98 63.52 130.05 9.41 139.46 139.46 01
Total Number of Same Buildings : 1
Total : 202.98 63.52 130.05 9.41 139.46 139.46 01
[-] Table 4c-2

  FAR Area
Building FAR Area:139.46
Existing FAR Area :0.00
Perm.
200.10
Prop.
139.46
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENTIAL) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 3.00 3.00 1.80 4.61 - 0.00 0.90 0.90 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (RESIDENTIAL)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENTIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
FIRST FLOOR PLAN STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.000 - 0.250 - 0.000 - 0 - - 2.885 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RWH - - 0.27 - - 0.59 - - 0.59 - - 0.00 OK
SHS - - 0.27 - - 0.59 - - 0.59 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENTIAL) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENTIAL)


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:GROUND FLOOR PLAN



No Room Found.



   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 130.50 OK
  Plot Width - 5.80 OK
  Plot Depth - 22.50 OK
  Access Width - 4.26 OK
  Plot Frontage - 5.80 OK
  Coverage Area 91.35 72.94 OK
  FAR Area
Bldg. FAR Area : 139.46
Sanctioned FAR Area :0.00
200.10 139.46 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RWH
(3) -
(4) No need to check distance from Building SHS
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)