No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 09-11-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0079/W09/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePardih
Taluka16
Architect Details
Architect NameSATISH KUMAR
License No.MNAC/DFTMN/0001/2017
Architect AddressB.B. PLACE HOLDING NO. - 181 , LANE NO. - 4 , BHUYADIH , JAMSHEDPUR
Architect EmailIDsrishti_designer@hotmail.com
Architect Mobile No9204750591
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1066 ( Part )
NorthPlot No. - JASWANT SINGH
SouthRoad Width - 3.65
EastPlot No. - 1080
WestRoad Width - 4.5
Owner's Details
NameMR . PRAMOD JAISWAL
AddressH. NO. 31 C , JAWAHAR ROAD , DAIGUTTU , MANGO , JAMSHEDPUR
Email IDjaiswal2010@gmail.com
Mobile No9279172601
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 118.51
2 Plot area as per Document by Applicant 118.51
3 Physical area measured at site 118.51
4 Area as per Site Visit (Site Visit Report) 118.51
5Area as per Drawing 118.51

Area of Plot Considered : 118.51

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 118.51
Deduction from Gross Plot area
- Surrender Free of Cost 3.51
3.51
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 114.99
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 98.15
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 3.51
- Common Plot 16.85
20.36
Balance Plot Area 98.15

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 80.49
Proposed Coverage Area ( 58.79 % ) 67.60
Total Prop. Coverage Area ( 58.79 % ) 67.60
Balance coverage area ( 11.21 % ) 12.89
FAR CHECK
Perm. FAR Area ( 1.500 ) 177.76
Total Perm. FAR area 177.76
Residential FAR 139.54
Proposed FAR Area 146.95
Total Proposed FAR Area 146.95
Consumed FAR (Factor) 1.24
Balance FAR Area 30.81
BUA CHECK
Total Proposed BuiltUp Area 215.00


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 4.5 4.50
Proposed Road Width as per Master Plan 4.5 -
Road Widening Width 0.3 -
Plot size (as per measurement) 118.51 118.51
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 114.99 OK
Plot Width Mt. - - 9.53 OK
Plot Depth Mt. - - 12.07 OK
Access Width Mt. - - 4.50 OK
Plot Frontage Mt. - - 11.79 OK
Coverage Area Sq.Mt. - 80.49 67.60 OK
FAR Area Sq.Mt. - 177.76 146.95 OK
Consumed FAR Sq.Mt. - 1.50 1.24 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 11.50 16.85 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 16.85 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.84 OK
Tree Cover (Plantation) - Angle Degree - 82.32 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 9 OK
Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 25.00 - 25.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 4.00 OK
Total TwoWheeler In Area Sq.Mt. - - 4.00 OK
Other Parking In Area Sq.Mt. - - 22.69 OK
A-1 (RESIDENTIAL) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 2.00 - 2.00 OK
Rear Margin Mt. 1.50 - 1.53 OK
Side1 Margin Mt. - - 0.00 OK
Side2 Margin Mt. 0.90 - 0.91 OK
A-1 (RESIDENTIAL) BldgLine for 4.5M WIDE ROAD Mt. 0.30 2.30 OK
A-1 (RESIDENTIAL) ResvRoad Width Check for... 4.5M WIDE ROAD Mt. 0.30 0.30 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL) Height Mt. 9.05 8.57 OK
A (RESIDENTIAL) Second Floor - Height Mt. 2.75 - 2.86 OK
Second Floor - Clear Height Mt. 2.75 - 2.76 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.49 OK
First Floor - Height Mt. 2.75 - 2.86 OK
First Floor - Clear Height Mt. 2.75 - 2.76 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.49 OK
Ground Floor - Height Mt. 2.75 - 2.86 OK
Ground Floor - Clear Height Mt. 2.75 - 2.76 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.49 OK
Plinth - Height Mt. 0.45 - 0.76 OK
Plinth - Clear Height Mt. - - 0.76 OK
Plinth - Beam Clear Height Mt. - - 0.76 OK
A (RESIDENTIAL) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (RESIDENTIAL) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 2 OK
A (RESIDENTIAL) TYPICAL - 1& 2 FLOOR PLAN - BALCONY - Width Mt. 0.90 0.89 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.068 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.068 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.068 OK
STAIRCASE - Tread Width Mt. - 0.267 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.593 OK
SUMP TANK Area Sq.Mt. - - 0.50 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 0.81 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.09 OK
Width Mt. - - 0.33 OK
Depth Mt. - - 0.33 OK
Height Mt. - - - OK
Area Sq.Mt. - - 0.67 OK
Width Mt. - - 0.93 OK
Depth Mt. - - 0.93 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.28 OK
Width Mt. - - 0.12 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 2.47 OK
Width Mt. - - 1.16 OK
Depth Mt. - - 2.14 OK
Height Mt. - - - OK
A (RESIDENTIAL) Rain Water Harvesting - No No. 1 - 2 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 0.9 mt. where the setback is between 2.0 mt. to 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)