Name |
Description |
Unit |
Reqd |
Perm |
Proposed |
Status |
|
A (RESIDENTIAL) |
Height |
Mt. |
|
11.66
|
9.91
|
OK
|
|
A (RESIDENTIAL) |
Second Floor - Height |
Mt. |
2.75
|
-
|
3.35
|
OK
|
Second Floor - Clear Height |
Mt. |
2.75
|
-
|
3.24
|
OK
|
Second Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.95
|
OK
|
First Floor - Height |
Mt. |
2.75
|
-
|
3.35
|
OK
|
First Floor - Clear Height |
Mt. |
2.75
|
-
|
3.24
|
OK
|
First Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.95
|
OK
|
Ground Floor - Height |
Mt. |
2.75
|
-
|
3.20
|
OK
|
Ground Floor - Clear Height |
Mt. |
2.75
|
-
|
3.09
|
OK
|
Ground Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.79
|
OK
|
Plinth - Height |
Mt. |
0.45
|
-
|
0.46
|
OK
|
Plinth - Clear Height |
Mt. |
-
|
-
|
0.46
|
OK
|
Plinth - Beam Clear Height |
Mt. |
-
|
-
|
0.46
|
OK
|
|
A (RESIDENTIAL) |
Terrace Floor - Height |
Mt. |
-
|
-
|
1.07
|
OK
|
Terrace Floor - Clear Height |
Mt. |
-
|
-
|
1.07
|
OK
|
Terrace Floor - Beam Clear Height |
Mt. |
-
|
-
|
1.07
|
OK
|
|
A (RESIDENTIAL) |
No. of Floors |
No. |
|
G + 4
|
3
|
OK
|
No. of Tenements |
No. |
|
-
|
1
|
OK
|
|
A (RESIDENTIAL) |
FIRST FLOOR PLAN - BALCONY - Width |
Mt. |
|
1.20
|
1.10
|
OK
|
SECOND FLOOR PLAN - BALCONY - Width |
Mt. |
|
1.20
|
0.92
|
OK
|
|
A (RESIDENTIAL) |
Number Of Lift(s) |
No. |
-
|
|
1
|
OK
|
Number Of Strature Lift(s) |
No. |
-
|
|
-
|
OK
|
Capacity Of Lift(s) Passanger |
No. |
-
|
|
6
|
OK
|
|
A (RESIDENTIAL) |
FIRST FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.70
|
OK
|
FIRST FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.90
|
OK
|
SECOND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.70
|
OK
|
SECOND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.90
|
OK
|
GROUND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.70
|
OK
|
GROUND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.90
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Depth |
Mt. |
1.90
|
|
3.82
|
OK
|
|
FIRST FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.029
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.250
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.108
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
15
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
Staircase -4FL - Flight Width |
Mt. |
0.900
|
|
0.914
|
OK
|
Staircase -4FL - Tread Width |
Mt. |
0.250
|
|
0.250
|
OK
|
Staircase -4FL - Riser Height |
Mt. |
|
0.200
|
0.076
|
OK
|
Staircase -4FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -4FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
SECOND FLOOR PLAN |
Staircase -4FL - Flight Width |
Mt. |
0.900
|
|
0.914
|
OK
|
Staircase -4FL - Tread Width |
Mt. |
0.250
|
|
0.250
|
OK
|
Staircase -4FL - Riser Height |
Mt. |
|
0.200
|
0.076
|
OK
|
Staircase -4FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -4FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
GROUND FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.029
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.250
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.103
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
15
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
Staircase -4FL - Flight Width |
Mt. |
0.900
|
|
0.914
|
OK
|
Staircase -4FL - Tread Width |
Mt. |
0.250
|
|
0.250
|
OK
|
Staircase -4FL - Riser Height |
Mt. |
|
0.200
|
0.094
|
OK
|
Staircase -4FL - Riser No. On Flight |
No. |
|
-
|
8
|
OK
|
Staircase -4FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
TERRACE FLOOR PLAN |
Staircase -4FL - Flight Width |
Mt. |
-
|
|
0.914
|
OK
|
Staircase -4FL - Tread Width |
Mt. |
-
|
|
0.250
|
OK
|
Staircase -4FL - Riser Height |
Mt. |
|
-
|
-
|
OK
|
Staircase -4FL - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
Staircase -4FL - Cabin Ht. |
Mt. |
-
|
-
|
2.426
|
OK
|
|
RAIN WATER HARVESTING |
Area |
Sq.Mt. |
-
|
-
|
0.73
|
OK
|
Width |
Mt. |
-
|
-
|
0.97
|
OK
|
Depth |
Mt. |
-
|
-
|
0.97
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
ENT.GATE |
Area |
Sq.Mt. |
-
|
-
|
0.82
|
OK
|
Width |
Mt. |
-
|
-
|
0.23
|
OK
|
Depth |
Mt. |
-
|
-
|
3.60
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
SOLAR HEATING SYSTEM |
Area |
Sq.Mt. |
-
|
-
|
0.79
|
OK
|
Width |
Mt. |
-
|
-
|
1.00
|
OK
|
Depth |
Mt. |
-
|
-
|
1.01
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
|
A (RESIDENTIAL) |
Rain Water Harvesting - No |
No. |
1
|
-
|
1
|
OK
|
Solar Water Heating System - No |
No. |
1
|
-
|
1
|
OK
|
Entrance Gate - No |
No. |
1
|
-
|
1
|
OK
|
|
|
[-] Rules
Topic |
Rule |
Plot Level |
Plot Area |
No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Plot Width |
No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Plot Depth |
No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Access Width |
The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
|
Plot Frontage |
No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
FAR Area |
(1)
In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2)
For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Consumed FAR |
(1)
In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2)
For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2)
;
|
Tree Number |
4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule |
For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 15-21 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
|
Building Level |
Building Height |
For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
|
Parapet Height |
(1)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Floor Number |
For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
|
Balcony |
Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Lift Count |
(1)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2)
For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
|
Lift |
(1)
The area of lift well shall not be counted for F.A.R calculation)
(2)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3)
The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5)
-
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
No Rule Defined
(4)
; No Rule Defined
|
Plot / Building Level |
Accessory Use |
(1)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2)
No need to check distance from Building RAIN WATER HARVESTING
(3)
No need to check distance from Building ENT.GATE
(4)
-
(5)
No need to check distance from Building SOLAR HEATING SYSTEM
|
Accessory Use Number |
(1)
Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2)
For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3)
In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
|
Building Level (Rooms) |
Foyer1.26x1.08
|
No Rule Defined |
Hall2.10x2.26
|
No Rule Defined |
Kitchen3.81x4.04
|
Area for Kitchen when store room is provided shall be Mini. 4.5 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2} |
Pantry
|
No Rule Defined |
Servant Room3.47x3.05
|
No Rule Defined |
Servant Room3.54x3.05
|
No Rule Defined |
Sitout1.09x6.73
|
No Rule Defined |
Sitout2.67x1.75
|
No Rule Defined |
Sitout2.90x4.72
|
No Rule Defined |
Toilet2.67x1.60
|
Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2} |
Wc1.26x1.30
|
No Rule Defined |
|