No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.71  
Version Date: 16/10/2020 
Report Generated On: 05-09-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0085/W09/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameSATISH KUMAR
License No.MNAC/DFTMN/0001/2017
Architect AddressB.B. PLACE HOLDING NO. - 181 , LANE NO. - 4 , BHUYADIH , JAMSHEDPUR
Architect EmailIDsrishti_designer@hotmail.com
Architect Mobile No9204750591
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2622 ( PART )
NorthRoad Width - 1.2 M WIDE ALLEY
SouthRoad Width - 5.48
EastPlot No. - NIJJ
WestPlot No. - S. RAHMAN
Owner's Details
NameMrs. REHANA KHATOON
AddressRESIDENCE OF H. NO. 22 , SABIR NAGAR , JAWAHARNAGAR , NEAR TAIYADA MASJID , P. O. - AZADNAGAR , JAMSHEDPUR.
Email IDrahmanjsr47@gmail.com
Mobile No7979067163
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 196.25
2 Plot area as per Document by Applicant 196.25
3 Physical area measured at site 196.25
4 Area as per Site Visit (Site Visit Report) 196.25
5Area as per Drawing 195.66

Area of Plot Considered : 195.66

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 195.66
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 195.66
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 174.86
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 20.80
20.80
Balance Plot Area 174.86

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 136.96
Proposed Coverage Area ( 69.55 % ) 136.09
Total Prop. Coverage Area ( 69.55 % ) 136.09
Balance coverage area ( 0.44 % ) 0.87
FAR CHECK
Perm. FAR Area ( 1.800 ) 352.19
Total Perm. FAR area 352.19
Residential FAR 239.23
Proposed FAR Area 252.22
Total Proposed FAR Area 252.22
Consumed FAR (Factor) 1.29
Balance FAR Area 99.97
BUA CHECK
Total Proposed BuiltUp Area 408.25


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 5.48 5.48
Proposed Road Width as per Master Plan 5.48 -
Road Widening Width 0 -
Plot size (as per measurement) 196.25 195.66
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 9.78 20.80 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Tree Cover (Plantation) - 20.80 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 15 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure No Of Residential Units Floor Name Floor Use Floor SubUse FAR Name FAR Use FAR SubUse
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise 4 GROUND FLOOR PLAN Residential Bungalow/ Dwelling / Non Apartment - - -
TYPICAL - 1& 2 FLOOR PLAN Residential Bungalow/ Dwelling / Non Apartment Residential FAR Residential Bungalow/ Dwelling / Non Apartment
TERRACE FLOOR PLAN Residential Bungalow/ Dwelling / Non Apartment - - -
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 10.00 8.54 8.54 8.54 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.55 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.55 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.55 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.07 - - 0.97 - - 0.97 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 2 3 - 4 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
136.96 136.09 OK
70% 69.55%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 136.09
  Total Prop. Coverage Area - 136.09
  Total Coverage Area 136.96 136.09

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Void Accessory Use Parking Resi. Stair
A (BUILDING) 1 408.25 8.34 3.92 20.68 123.09 239.22 8.83 252.22 252.22 04
Grand Total : 1 408.25 8.34 3.92 20.68 123.09 239.22 8.83 252.22 252.22 04


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 136.09 13.00 136.09 13.00
First Floor 136.08 119.61 136.08 119.61
Second Floor 136.08 119.61 136.08 119.61
Terrace Floor 0.00 0.00 0.00 0.00
Total : 408.25 252.22 408.25 252.22


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
TYPICAL - 1& 2 FLOOR PLAN 1 FLAT 52.78 50.89 5 4
2 FLAT 54.46 52.16 5
Total: - - 214.48 206.10 20 4


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Void Accessory Use Parking Resi. Stair
Ground Floor 136.09 0.00 0.00 0.00 123.09 0.00 8.83 13.00 13.00 00
First Floor 136.08 4.17 1.96 10.34 0.00 119.61 0.00 119.61 119.61 02
Second Floor 136.08 4.17 1.96 10.34 0.00 119.61 0.00 119.61 119.61 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 408.25 8.34 3.92 20.68 123.09 239.22 8.83 252.22 252.22 04
Total Number of Same Buildings : 1
Total : 408.25 8.34 3.92 20.68 123.09 239.22 8.83 252.22 252.22 04
[-] Table 4c-2

  FAR Area
Building FAR Area:252.22
Existing FAR Area :0.00
Perm.
352.19
Prop.
252.22
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 5.48 M WIDE ROAD 2.50 2.63 1.50 1.68 0.90 1.12 - 0.00 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (BUILDING) 8.54 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.71 1.90 2.44 OK
TYPICAL - 1& 2 FLOOR PLAN Lift 1.70 1.71 1.90 2.44 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.71 1.90 2.44 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment > 0 1 4.00 1.00 4 - - - - - - -
> 0 1 4.00 - - - 1 1 - - - -
Total : - - - - 4 4 - 1 1 - 0 4

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 4 50.00 OK
Total Car 4 50.00 4 50.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
TwoWheeler - - 4 8.00 OK
Total TwoWheeler - - 4 8.00 OK
Other Parking - - - 60.59 OK
Total 62.50 139.09 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.267 0.200 0.150 - 9 - - 0.000 OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.267 0.200 0.150 - 9 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.219 - 0.267 - 0.000 - 0 - - 2.591 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 1.16 - - 0.77 - - 1.50 - - 0.00 OK
RAIN WATER HARVESTING - - 0.43 - - 0.74 - - 0.74 - - 0.00 OK
ENT.GATE - - 1.04 - - 0.21 - - 4.94 - - 0.00 OK
Entrance Lobby - 12.00 7.09 - - 1.88 - - 3.77 - - 0.00 OK
Entrance Lobby - 12.00 3.25 - - 1.22 - - 2.67 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 195.66 OK
  Plot Width - 9.75 OK
  Plot Depth - 20.06 OK
  Access Width - 5.48 OK
  Plot Frontage - 9.75 OK
  Coverage Area 136.96 136.09 OK
  FAR Area
Bldg. FAR Area : 252.22
Sanctioned FAR Area :0.00
352.19 252.22 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room3.27x2.93 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.27x2.95 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.42x2.94 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.47x2.93 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Hall2.67x1.05 No Rule Defined
Hall5.63x2.91 No Rule Defined
Kitchen3.64x1.83 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Toilet1.45x3.04 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}