No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 04-07-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0057/W08/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePardih
Taluka16
Architect Details
Architect NameMOHAMMAD BELAL NASIR
License No.MNAC/ENG/0007/2016
Architect AddressHOLDING No: 02, CROSS ROAD No:1/D, AZAD NAGAR, MANGO
Architect EmailIDdreamdesign.jsr.bn@gmail.com
Architect Mobile No9835307058
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No3550
North -
South -
East -
West -
Owner's Details
NameMR.EHSAN AHMAD
AddressH.No 431, Road No 2, Zakirnagar, Azadnagar, Mango, Jamshedpur.
Email IDddofficial.bn@gmail.com
Mobile No6205159573
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 267.09
2 Plot area as per Document by Applicant 248.08
3 Physical area measured at site 248.08
4 Area as per Site Visit (Site Visit Report) 248.08
5Area as per Drawing 284.08

Area of Plot Considered : 248.08

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 248.08
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 248.08
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 212.38
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 35.70
35.70
Balance Plot Area 212.38

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 148.85
Proposed Coverage Area ( 56.32 % ) 139.72
Total Prop. Coverage Area ( 56.32 % ) 139.72
Balance coverage area ( 3.68 % ) 9.13
FAR CHECK
Perm. FAR Area ( 2.500 ) 620.20
Total Perm. FAR area 620.20
Residential FAR 564.09
Proposed FAR Area 579.03
Total Proposed FAR Area 579.03
Consumed FAR (Factor) 2.33
Balance FAR Area 41.17
BUA CHECK
Total Proposed BuiltUp Area 742.72


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 8 8.00
Proposed Road Width as per Master Plan 8 -
Road Widening Width 0 -
Plot size (as per measurement) 248.08 284.08
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 12.40 35.70 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 5.37 0.00 0.00 - 0.42 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 7.17 0.00 0.00 - 0.91 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 23.16 0.00 0.00 - 1.95 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 21 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SMT ISHRAR FATMA) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SMT ISHRAR FATMA) 15.00 14.25 14.25 14.25 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SMT ISHRAR FATMA) Fourth Floor 2.75 - 2.85 2.75 - 2.74 2.40 - 2.55 Failed
Third Floor 2.75 - 2.85 2.75 - 2.74 2.40 - 2.55 Failed
Second Floor 2.75 - 2.85 2.75 - 2.74 2.40 - 2.55 Failed
First Floor 2.75 - 2.85 2.75 - 2.74 2.40 - 2.55 Failed
Ground Floor 2.75 - 2.85 2.75 - 2.74 2.40 - 2.55 Failed
Plinth 0.45 - 0.58 - - 0.58 - - 0.58 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SMT ISHRAR FATMA) Terrace Floor - - 1.07 - - 1.07 - - 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SMT ISHRAR FATMA) G + 5 5 - 6 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
148.85 139.72 OK
60% 56.32%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SMT ISHRAR FATMA) - 139.72
  Total Prop. Coverage Area - 139.72
  Total Coverage Area 148.85 139.72

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Resi. Stair
A (SMT ISHRAR FATMA) 1 742.72 16.84 22.06 124.78 564.10 10.73 579.04 579.04 06
Grand Total : 1 742.72 16.84 22.06 124.78 564.10 10.73 579.04 579.04 06


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SMT ISHRAR FATMA)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 139.72 14.94 139.72 14.94
First Floor 139.72 135.51 139.72 135.51
Second Floor 139.72 135.51 139.72 135.51
Third Floor 161.78 146.54 161.78 146.54
Fourth Floor 161.78 146.54 161.78 146.54
Terrace Floor 0.00 0.00 0.00 0.00
Total : 742.72 579.04 742.72 579.04


[-] UnitBUA Table for Building :A (SMT ISHRAR FATMA)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
TYPICAL - 1 & 2 FLOOR PLAN HALL-A FLAT 110.72 110.55 2 2
TYPICAL - 3 & 4 FLOOR PLAN UNIT NO-1 FLAT 54.87 54.67 6 4
UNIT NO-2 FLAT 54.87 54.67 6
Total: - - 440.93 439.79 28 6


[-] Building :A (SMT ISHRAR FATMA)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Resi. Stair
Ground Floor 139.72 0.00 0.00 124.78 0.00 10.73 14.94 14.94 00
First Floor 139.72 4.21 0.00 0.00 135.51 0.00 135.51 135.51 01
Second Floor 139.72 4.21 0.00 0.00 135.51 0.00 135.51 135.51 01
Third Floor 161.78 4.21 11.03 0.00 146.54 0.00 146.54 146.54 02
Fourth Floor 161.78 4.21 11.03 0.00 146.54 0.00 146.54 146.54 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 742.72 16.84 22.06 124.78 564.10 10.73 579.04 579.04 06
Total Number of Same Buildings : 1
Total : 742.72 16.84 22.06 124.78 564.10 10.73 579.04 579.04 06
[-] Table 4c-2

  FAR Area
Building FAR Area:579.03
Existing FAR Area :0.00
Perm.
620.20
Prop.
579.03
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SMT ISHRAR FATMA) 8.0 MTR WIDE MAINROAD 3.00 3.00 2.00 3.00 2.00 2.00 2.00 2.00 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (SMT ISHRAR FATMA)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 3 & 4 FLOOR PLAN BALCONY 1.20 1.10 OK
BALCONY 1.20 1.10 OK
BALCONY 0.90 1.10 Failed
BALCONY 0.90 1.10 Failed
BALCONY 1.20 1.10 OK
BALCONY 1.20 1.10 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (SMT ISHRAR FATMA) 14.25 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (SMT ISHRAR FATMA)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.76 1.90 2.40 OK
GROUND FLOOR PLAN Lift 1.70 1.76 1.90 2.40 OK
TYPICAL - 1 & 2 FLOOR PLAN Lift 1.70 1.76 1.90 2.40 OK
TYPICAL - 3 & 4 FLOOR PLAN Lift 1.70 1.76 1.90 2.40 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SMT ISHRAR FATMA) Residential Residential Bldg/Apartment > 0 1 6.00 1.00 6 - - - - - - -
> 0 1 6.00 - - - - - - 1 6 -
> 0 1 6.00 - - - 1 1 - - - -
Total : - - - - 6 18 - 1 0 - 6 7

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Total Car 6 75.00 18 243.00 OK
Parallel Car - - 18 243.00 OK
Total Visitor Parking 1 12.50 0 0.00 FAILED
TwoWheeler - - 7 14.00 OK
Total TwoWheeler 6 12.00 7 14.00 OK
ERiksha Stand Area - - 18 243.00 OK
Other Parking - - - 70.78 OK
Total 99.50 584.78 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SMT ISHRAR FATMA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
TERRACE FLOOR PLAN STAIRCASE - 1.200 - 0.250 - 0.000 - 0 - - 2.500 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.143 - 10 - - 0.000 OK
TYPICAL - 1 & 2 FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.143 - 10 - - 0.000 OK
TYPICAL - 3 & 4 FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.143 - 10 - - 0.000 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
1.11 mt. long 0.15 mt. High 5.05 mt. Wide Natural Slope - 1.11 - 0.15 - - - OK
1.11 mt. long 0.15 mt. High 5.05 mt. Wide Natural Slope - 1.11 - 0.15 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (SMT ISHRAR FATMA) GROUND FLOOR PLAN - 2 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 0.56 - - 0.65 - - 0.87 - - 0.00 OK
SewageTreatmentPlant - - 0.72 - - 0.82 - - 0.88 - - 0.00 OK
RAIN WATERHARVESTING - - 0.56 - - 0.65 - - 0.87 - - 0.00 OK
ENT.GATE - - 1.18 - - 0.40 - - 3.00 - - 0.00 OK
SOLARHEATING SYSTEM - - 5.95 - - 2.22 - - 2.69 - - 0.00 OK
Generator Room - - 0.56 - - 0.65 - - 0.87 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SMT ISHRAR FATMA) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SMT ISHRAR FATMA)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:TYPICAL - 1 & 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 3 & 4 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 248.08 OK
  Plot Width - 16.76 OK
  Plot Depth - 16.95 OK
  Access Width 6.10 8.00 OK
  Plot Frontage - 16.76 OK
  Coverage Area 148.85 139.72 OK
  FAR Area
Bldg. FAR Area : 579.03
Sanctioned FAR Area :0.00
620.20 579.03 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 2.0 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony (1) Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Projected balcony may be allowed with a widt of 0.9 mt. where the setback is between 2.0 mt. to 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) -
(2) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(4) The area of lift well shall not be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. -
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SewageTreatmentPlant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATERHARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLARHEATING SYSTEM
(10) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(11) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bed Room3.00x3.28 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.50x4.09 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Hall4.72x2.88 No Rule Defined
Hall4.72x6.40 No Rule Defined
Kitchen2.41x2.27 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Toilet1.60x3.28 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.41x1.70 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}