No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.69  
Version Date: 16/10/2020 
Report Generated On: 08-04-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0023/W10/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameL K Suman
License No.MNAC/ENG/0008/2016
Architect Address2nd Floor, Basant Talkies Complex, Sankchi, Jamshedpur
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No2517
NorthRoad Width - 30.5
SouthPlot No. - ALLEY
EastPlot No. - CHANDIGIRAM AGARWAL
WestPlot No. - VIMAL SINGH
Owner's Details
NameVIKRAM SINGH AND OTHERS
AddressPLOT NO.- 2517, KHATA NO.- 468, MOUZA - MANGO, JAMSHEDPUR, EAST SINGHBHUM.
Email IDvs4077727@gmail.com
Mobile No8092088312
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 139.67
2 Plot area as per Document by Applicant 139.67
3 Physical area measured at site 139.65
4 Area as per Site Visit (Site Visit Report) 139.65
5Area as per Drawing 139.65

Area of Plot Considered : 139.65

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 139.65
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 139.65
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 122.07
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 17.58
17.58
Balance Plot Area 122.07

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 69.82
Proposed Coverage Area ( 39.70 % ) 55.44
Total Prop. Coverage Area ( 39.7 % ) 55.44
Balance coverage area ( 10.30 % ) 14.38
FAR CHECK
Perm. FAR Area ( 3.000 ) 418.95
Total Perm. FAR area 418.95
Commercial FAR 287.44
Proposed FAR Area 299.19
Total Proposed FAR Area 299.19
Consumed FAR (Factor) 2.14
Balance FAR Area 119.76
BUA CHECK
Total Proposed BuiltUp Area 368.71


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 600 meter and upto 1000 meter -
Existing Road Width 30.5 30.50
Proposed Road Width as per Master Plan 30.5 -
Road Widening Width 0 -
Plot size (as per measurement) 139.65 139.65
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 139.65 OK
Plot Width Mt. - - 9.91 OK
Plot Depth Mt. - - 14.09 OK
Access Width Mt. 6.10 - 30.50 OK
Plot Frontage Mt. - - 9.91 OK
Coverage Area Sq.Mt. - 69.82 55.44 OK
FAR Area Sq.Mt. - 418.95 299.19 OK
Consumed FAR Sq.Mt. - 3.00 2.14 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 6.98 17.58 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 17.58 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.47 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 9 OK
Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 25.00 - 25.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. - - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 10.00 OK
Total TwoWheeler In Area Sq.Mt. 10.00 - 10.00 OK
Other Parking In Area Sq.Mt. - - 22.73 OK
A-1 (COMMERCIAL BUILDING) Front Margin... 30.50 M WIDE DIMNA ROAD Mt. 4.50 - 4.50 OK
Rear Margin Mt. 2.00 - 3.00 OK
Side1 Margin Mt. 1.50 - 1.50 OK
Side2 Margin Mt. - - 0.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (COMMERCIAL BUILDING) Height Mt. 50.25 16.20 OK
A (COMMERCIAL BUILDING) Fourth Floor - Height Mt. 2.75 - 2.85 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.75 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
Third Floor - Height Mt. 2.75 - 2.85 OK
Third Floor - Clear Height Mt. 2.75 - 2.75 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Clear Height Mt. 2.75 - 2.75 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
First Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Clear Height Mt. 2.75 - 2.75 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
Lower Ground Floor - Height Mt. 2.75 - 2.85 OK
Lower Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Lower Ground Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
A (COMMERCIAL BUILDING) Terrace Floor - Height Mt. - - 1.10 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (COMMERCIAL BUILDING) No. of Floors No. - 6 OK
No. of Tenements No. - 5 OK
A (COMMERCIAL BUILDING) Number Of Lift(s) No. 2 2 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. 12 12 OK
A (COMMERCIAL BUILDING) LOWER GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
LOWER GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
LOWER GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
LOWER GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
LOWER GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.200 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.39 OK
Width Mt. - - 1.39 OK
Depth Mt. - - 1.72 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.41 OK
Width Mt. - - 0.20 OK
Depth Mt. - - 2.06 OK
Height Mt. - - - OK
Area Sq.Mt. - - 0.40 OK
Width Mt. - - 0.21 OK
Depth Mt. - - 1.91 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 3.93 OK
Width Mt. - - 1.26 OK
Depth Mt. - - 3.11 OK
Height Mt. - - - OK
A (COMMERCIAL BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 3.00 mt. long 0.90 mt. High 3.60 mt. Wide Natural Slope - Width Mt. - 3.00 OK
3.00 mt. long 0.90 mt. High 3.60 mt. Wide Natural Slope - Depth Mt. - 0.90 OK
3.00 mt. long 0.90 mt. High 3.60 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (COMMERCIAL BUILDING) - LOWER GROUND FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 10-15 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.5 mt., Rear 2.0 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 }
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)