-
No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 03-05-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0021/W08/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameMOHAMMAD BELAL NASIR
License No.MNAC/ENG/0007/2016
Architect AddressHOLDING No: 02, CROSS ROAD No:1/D, AZAD NAGAR, MANGO
Architect EmailIDdreamdesign.jsr.bn@gmail.com
Architect Mobile No9835307058
Plot Details
Plot Use Residential
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No3592,3592/4438
North -
South -
East -
West -
Owner's Details
NameMR. SYED ZULFAQUAR HUSSAIN RIZVI
AddressMunshi Mohalla, Mango, Jamshedpur
Email IDdreamdesign.bn@gmail.com
Mobile No6205159573
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 278.82
2 Plot area as per Document by Applicant 278.42
3 Physical area measured at site 278.42
4 Area as per Site Visit (Site Visit Report) 278.42
5Area as per Drawing 278.42

Area of Plot Considered : 278.42

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse ResiComm Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 278.42
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 278.42
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 250.38
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 28.04
28.04
Balance Plot Area 250.38

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 167.05
Proposed Coverage Area ( 44.19 % ) 123.02
Total Prop. Coverage Area ( 44.19 % ) 123.02
Balance coverage area ( 15.81 % ) 44.03
FAR CHECK
Perm. FAR Area ( 2.500 ) 696.05
Total Perm. FAR area 696.05
Residential FAR 436.89
Commercial FAR 164.91
Proposed FAR Area 613.59
Total Proposed FAR Area 613.59
Consumed FAR (Factor) 2.20
Balance FAR Area 82.46
BUA CHECK
Total Proposed BuiltUp Area 736.70


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 9.14 9.14
Proposed Road Width as per Master Plan 9.14 -
Road Widening Width 0 -
Plot size (as per measurement) 278.42 278.42
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 278.42 OK
Plot Width Mt. - - 15.11 OK
Plot Depth Mt. - - 18.43 OK
Access Width Mt. 6.10 - 9.14 OK
Plot Frontage Mt. - - 15.11 OK
Coverage Area Sq.Mt. - 167.05 123.02 OK
FAR Area Sq.Mt. - 696.05 613.59 OK
Consumed FAR Sq.Mt. - 2.50 2.20 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 27.84 28.04 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 28.04 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.87 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 6 OK
Car In Area Sq.Mt. - - 75.02 OK
Total Car In Area Sq.Mt. 75.00 - 75.02 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.51 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.51 OK
TwoWheeler In Area Sq.Mt. - - 20.11 OK
Total TwoWheeler In Area Sq.Mt. 20.00 - 20.11 OK
Other Parking In Area Sq.Mt. - - 41.97 OK
DriveWay A (SYED ZULFAQUAR HUSSAIN RIZVI ) - GROUND FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 3.61 OK
A-1 (SYED ZULFAQUAR HUSSAIN RIZVI ) Front Margin... 9.14 MT. WIDE MAINROAD Access Road Mt. 3.00 - 3.06 OK
Rear Margin Mt. 2.00 - 3.06 OK
Side1 Margin Mt. 2.00 - 2.01 OK
Side2 Margin Mt. 2.00 - 2.01 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SYED ZULFAQUAR HUSSAIN RIZVI ) Height Mt. 16.77 14.41 OK
A (SYED ZULFAQUAR HUSSAIN RIZVI ) Fourth Floor - Height Mt. 2.75 - 2.88 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.76 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.58 OK
Third Floor - Height Mt. 2.75 - 2.88 OK
Third Floor - Clear Height Mt. 2.75 - 2.76 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.58 OK
Second Floor - Height Mt. 2.75 - 2.88 OK
Second Floor - Clear Height Mt. 2.75 - 2.76 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.58 OK
First Floor - Height Mt. 2.75 - 2.88 OK
First Floor - Clear Height Mt. 2.75 - 2.76 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.58 OK
Ground Floor - Height Mt. 2.75 - 2.88 OK
Ground Floor - Clear Height Mt. 2.75 - 2.76 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.58 OK
Plinth - Height Mt. 0.45 - 0.46 OK
Plinth - Clear Height Mt. - - 0.46 OK
Plinth - Beam Clear Height Mt. - - 0.46 OK
A (SYED ZULFAQUAR HUSSAIN RIZVI ) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (SYED ZULFAQUAR HUSSAIN RIZVI ) No. of Floors No. G + 6 5 OK
No. of Tenements No. - 5 OK
A (SYED ZULFAQUAR HUSSAIN RIZVI ) GROUND FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.06 OK
GROUND FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.21 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 2.06 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 2.21 OK
TYPICAL - 2,3,4 FLOOR PLAN - Lift - Width Mt. 1.70 2.06 OK
TYPICAL - 2,3,4 FLOOR PLAN - Lift - Depth Mt. 1.90 2.21 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.06 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.21 OK
GROUND FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.105 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.254 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.144 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.143 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.120 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.105 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.254 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.144 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.143 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.120 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 2,3,4 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.143 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.120 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.143 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.438 OK
Sewage Treatment Plant Area Sq.Mt. - - 3.17 OK
Width Mt. - - 0.80 OK
Depth Mt. - - 3.97 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.89 OK
Width Mt. - - 1.06 OK
Depth Mt. - - 1.07 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.04 OK
Width Mt. - - 0.31 OK
Depth Mt. - - 3.39 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 3.17 OK
Width Mt. - - 0.80 OK
Depth Mt. - - 3.97 OK
Height Mt. - - - OK
A (SYED ZULFAQUAR HUSSAIN RIZVI ) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 2.0 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift (1) -
(2) The area of lift well shall not be counted for F.A.R calculation)
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
(5) No Rule Defined
(6) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bed Room3.50x3.05 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.50x3.20 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.50x3.78 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.54x2.83 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Hall3.36x2.94 No Rule Defined
Kitchen1.87x3.05 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Sitout2.63x0.91 No Rule Defined
Sitout3.36x1.06 No Rule Defined
Sitout3.73x0.91 No Rule Defined
Sitout3.73x1.06 No Rule Defined
Sitout3.77x1.06 No Rule Defined
Toilet2.31x1.22 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.44x1.22 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}