No Image Found

PreDCR Report

CHATRA NAGAR PRISHAD

Version Number: 1.0.29
Version Date: 30/06/2018
Report Generated On : 03-10-2018

General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictCHATRA
AuthorityCHATRA NAGAR PRISHAD
AuthorityNameChatra Nagar Prishad
Inward_NoCHNP/BP/0013/W17/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Case TypeNew
LocationOld Area
SubLocationNA
Ward NoW17
Village/Mauza NameChatra
Architect Details
Architect NameLAW CHATURVEDI
License No.CHNP/ENG/0004/2017
Architect AddressVILL.-LEMBOGRA,P.O-GANGI,P.S-BARACHATTI,GAYA
Architect EmailIDlaw8688@gmail.com
Architect Mobile No8987252771
Plot Details
Plot UseResidential
Plot SubUseBungalow/ Dwelling / Non Apartment
Land Use ZoneResidential
AbuttingRoadWidth50
Plot No642
Khata No47
Holding No0170000295000X4
Thana No184
North-
South-
East-
West-
Developer Details
Builder Name
Builder License No.
 
 
Owner's Details
NameVIJAY KUMAR AGRWAL
AddressLIPDA GODAM
OWNERS_EMAILIDlaw8688@gmail.com
OWNERS_MOBILENO8987252771
 
Drawing is not drawn on required PreDCR Layers, therefore AutoDCR reports can not be generated:

Minimum requied entities:
Listed objects are not found on PreDCR Layers.
1 Room.


AutoDCR reports can not be generated due to following failing entities on PreDCR Layer:

Failed Information:
    Failed Plot
Plot Name Failed Information Entity Reference
Entity does not contain any text.. 19A4FC

Failed MarginLine
Plot Name MarginLine Name Failed Information Entity Reference
- This Entity should be Open Polyline.. 19A47A

Failed RecreationalOpenSpace
Plot Name RecreationalOpenSpace Name Failed Information Entity Reference
- Entity does not contain any text.. 19A4D7

Failed FloorInSection
Building Name Floor Name FloorInSection Name Failed Information Entity Reference
A (A1) %%USECTION FIRST FLOOR Corresponding floor was not found.. 18CE07

Failed ResiFAR
Building Name Floor Name ResiFAR Name Failed Information Entity Reference
A (A1) GROUND FLOOR PLAN Entity Must Contain UnitBUA Poly Inside It.. 19082F

Failed StairCase
Building Name Floor Name StairCase Name Failed Information Entity Reference
A (A1) GROUND FLOOR PLAN Entity is not closed.. 19A47D
GROUND FLOOR PLAN Entity is not closed.. 19A482
GROUND FLOOR PLAN Entity is not closed.. 19A483
GROUND FLOOR PLAN Entity is not closed.. 19A484
GROUND FLOOR PLAN Entity is not closed.. 19A485
GROUND FLOOR PLAN Entity is not closed.. 19A487
GROUND FLOOR PLAN Entity is not closed.. 19A488
GROUND FLOOR PLAN Entity is not closed.. 19A489
GROUND FLOOR PLAN Entity is not closed.. 19A48A
GROUND FLOOR PLAN Entity is not closed.. 19A48B
GROUND FLOOR PLAN Entity is not closed.. 19A48C
GROUND FLOOR PLAN Entity is not closed.. 19A495
GROUND FLOOR PLAN Entity is not closed.. 19A496
GROUND FLOOR PLAN Entity is not closed.. 19A497
GROUND FLOOR PLAN Entity is not closed.. 19A498
GROUND FLOOR PLAN Entity is not closed.. 19A499
GROUND FLOOR PLAN Entity is not closed.. 19A49A
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A49B
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A49C
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A49D
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A49E
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A49F
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A0
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A1
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A2
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A3
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A4
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A5
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A6
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A7
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A8
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4A9
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4AA
FIRST FLOOR FLOOR PLAN Entity is not closed.. 19A4AB
SECOND FLOOR PLAN Entity is not closed.. 19A4AC
SECOND FLOOR PLAN Entity is not closed.. 19A4AD
SECOND FLOOR PLAN Entity is not closed.. 19A4AE
SECOND FLOOR PLAN Entity is not closed.. 19A4AF
SECOND FLOOR PLAN Entity is not closed.. 19A4B0
SECOND FLOOR PLAN Entity is not closed.. 19A4B1
SECOND FLOOR PLAN Entity is not closed.. 19A4B2
SECOND FLOOR PLAN Entity is not closed.. 19A4B3
SECOND FLOOR PLAN Entity is not closed.. 19A4B4
SECOND FLOOR PLAN Entity is not closed.. 19A4B5
SECOND FLOOR PLAN Entity is not closed.. 19A4B6
SECOND FLOOR PLAN Entity is not closed.. 19A4B7
SECOND FLOOR PLAN Entity is not closed.. 19A4B8
SECOND FLOOR PLAN Entity is not closed.. 19A4B9
SECOND FLOOR PLAN Entity is not closed.. 19A4BA
SECOND FLOOR PLAN Entity is not closed.. 19A4BB
SECOND FLOOR PLAN Entity is not closed.. 19A4BC
TERRACE FLOOR PLAN Entity is not closed.. 19A4BD
TERRACE FLOOR PLAN Entity is not closed.. 19A4BE
TERRACE FLOOR PLAN Entity is not closed.. 19A4BF
TERRACE FLOOR PLAN Entity is not closed.. 19A4C0
TERRACE FLOOR PLAN Entity is not closed.. 19A4C1
TERRACE FLOOR PLAN Entity is not closed.. 19A4C2
TERRACE FLOOR PLAN Entity is not closed.. 19A4C3
TERRACE FLOOR PLAN Entity is not closed.. 19A4C4
TERRACE FLOOR PLAN Entity is not closed.. 19A4C5
TERRACE FLOOR PLAN Entity is not closed.. 19A4C6
TERRACE FLOOR PLAN Entity is not closed.. 19A4C7
TERRACE FLOOR PLAN Entity is not closed.. 19A4C8
TERRACE FLOOR PLAN Entity is not closed.. 19A4C9
TERRACE FLOOR PLAN Entity is not closed.. 19A4CA
TERRACE FLOOR PLAN Entity is not closed.. 19A4CB
TERRACE FLOOR PLAN Entity is not closed.. 19A4CC
TERRACE FLOOR PLAN Entity is not closed.. 19A4CD

Failed Floor
Building Name Floor Name Failed Information Entity Reference
A (A1) GROUND FLOOR PLAN Floor is not having Staircase Poly.. 19A811
FIRST FLOOR FLOOR PLAN Floor is not having Staircase Poly. Corresponding FloorInSection was not found.. 19A812
SECOND FLOOR PLAN Floor is not having Staircase Poly.. 19A813

Failed Window
Building Name Floor Name Window Name Failed Information Entity Reference
A (A1) GROUND FLOOR PLAN W Entity is supposed to touch one of following entities. Balcony UnitBUA Room Passage StairCase.. 19A81A
GROUND FLOOR PLAN W Entity is supposed to touch one of following entities. Balcony UnitBUA Room Passage StairCase.. 19A81B
GROUND FLOOR PLAN W Entity is supposed to touch one of following entities. Balcony UnitBUA Room Passage StairCase.. 19A81C
GROUND FLOOR PLAN W1 Entity is supposed to touch one of following entities. Balcony UnitBUA Room Passage StairCase.. 19A81D
GROUND FLOOR PLAN W1 Entity contains more than one text. PreDCR requires only one text in each entity. Entity is supposed to touch one of following entities. Balcony UnitBUA Room Passage StairCase.. 19A81F
GROUND FLOOR PLAN W Entity is supposed to touch one of following entities. Balcony UnitBUA Room Passage StairCase.. 19A821

Failed Door
Building Name Floor Name Door Name Failed Information Entity Reference
A (A1) GROUND FLOOR PLAN D1 Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A854
GROUND FLOOR PLAN D1 Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A856
GROUND FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A867
GROUND FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A878
GROUND FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A888
FIRST FLOOR FLOOR PLAN D1 Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A88B
FIRST FLOOR FLOOR PLAN D1 Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A88D
FIRST FLOOR FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A88E
FIRST FLOOR FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A890
FIRST FLOOR FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A892
SECOND FLOOR PLAN D1 Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A8A1
SECOND FLOOR PLAN D1 Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A8A3
SECOND FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A8A4
SECOND FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A8A6
SECOND FLOOR PLAN D Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A8A8
GROUND FLOOR PLAN D1 Entity is supposed to touching one of following entities : Room UnitBUA StairCase Passage Balcony. 19A8B5









CHATRA NAGAR PRISHAD