Failed List Report

Chatra Nagar Prishad

Version Number: 1.0.53  
Version Date: 16/10/2020 
Report Generated On: 06-01-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictCHATRA
AuthorityCHATRA NAGAR PRISHAD
Inward_NoCHNP/BP/0006/W03/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageChatra
Taluka19
Architect Details
Architect NameLAW CHATURVEDI
License No.CHNP/ENG/0004/2017
Architect AddressVILL.-LEMBOGRA,P.O-GANGI,P.S-BARACHATTI,GAYA
Architect EmailIDlaw8688@gmail.com
Architect Mobile No8987252771
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot No24
NorthRoad Width - ROAD
SouthPlot No. - TALAB
EastPlot No. - KUNTI DEVI
WestPlot No. - LAL GUPTA
Owner's Details
NameKANTI DEVI LILA DEVI
AddressMAUZA.-CHAUR P.S.-CHATRA,DIST.-CHATRA(JHARKHAND)
Email IDlaw8688@gmail.com
Mobile No8987252771
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 662.10
2 Plot area as per Document by Applicant 662.10
3 Physical area measured at site 662.10
4 Area as per Site Visit (Site Visit Report) 662.10
5Area as per Drawing 661.13

Area of Plot Considered : 661.13

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 661.13
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 661.13
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 572.84
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 88.29
88.29
Balance Plot Area 572.84

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 330.57
Proposed Coverage Area ( 20.03 % ) 132.45
Total Prop. Coverage Area ( 20.03 % ) 132.45
Balance coverage area ( 29.97 % ) 198.12
FAR CHECK
Perm. FAR Area ( 2.00 ) 1322.26
Total Perm. FAR area 1322.26
Commercial FAR 264.91
Proposed FAR Area 264.91
Total Proposed FAR Area 264.91
Consumed FAR (Factor) 0.40
Balance FAR Area 1057.35
BUA CHECK
Total Proposed BuiltUp Area 264.90


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 15.2 15.20
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 662.1 661.13
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Chatra Nagar Prishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Chatra Nagar Prishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width upto 10 mt., Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)