-
No Image Found   

Check List Report

Chatra Nagar Prishad

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 24-02-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictCHATRA
AuthorityCHATRA NAGAR PRISHAD
Inward_NoCHNP/BP/0007/W15/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageChatra
Taluka19
Architect Details
Architect NameLAW CHATURVEDI
License No.CHNP/ENG/0004/2017
Architect AddressVILL.-LEMBOGRA,P.O-GANGI,P.S-BARACHATTI,GAYA
Architect EmailIDlaw8688@gmail.com
Architect Mobile No8987252771
Plot Details
Plot Use Commercial
Plot SubUse Showroom
PlotNearbyReligiousStructure NA
Plot/SubPlot No1262
NorthPlot No. - HARI RAM
SouthPlot No. - NIZ VENDER
EastPlot No. - USMAN MIYA
WestRoad Width - ROADHARI RAM
Owner's Details
NameARJUN PRASAD ARYA
AddressMAUZA.-KISUNPUR P.S.-CHATRA DIST.-CHATRA(JHARKHAND)
Email IDlaw8688@gmail.com
Mobile No8987252771
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1600.86
2 Plot area as per Document by Applicant 1600.86
3 Physical area measured at site 1600.86
4 Area as per Site Visit (Site Visit Report) 1600.86
5Area as per Drawing 1485.00

Area of Plot Considered : 1485.00

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Showroom
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1485.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1485.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1330.49
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 154.51
154.51
Balance Plot Area 1330.49

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 742.50
Proposed Coverage Area ( 32.40 % ) 481.14
Total Prop. Coverage Area ( 32.4 % ) 481.14
Balance coverage area ( 17.60 % ) 261.36
FAR CHECK
Perm. FAR Area ( 2.000 ) 2970.00
Total Perm. FAR area 2970.00
Commercial FAR 481.14
Proposed FAR Area 481.14
Total Proposed FAR Area 481.14
Consumed FAR (Factor) 0.32
Balance FAR Area 2488.86
BUA CHECK
Total Proposed BuiltUp Area 481.14


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 12.1 12.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 1600.86 1485.00
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 1485.00 OK
Plot Width Mt. - - 33.00 OK
Plot Depth Mt. - - 45.00 OK
Access Width Mt. - - 12.10 OK
Plot Frontage Mt. - - 33.00 OK
Coverage Area Sq.Mt. - 742.50 481.14 OK
FAR Area Sq.Mt. - 2970.00 481.14 OK
Consumed FAR Sq.Mt. - 2.00 0.32 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 74.25 154.51 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 154.51 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.92 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 20 OK
Car In Area Sq.Mt. - - 75.00 OK
Total Car In Area Sq.Mt. 25.00 - 75.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 37.50 OK
Total Visitor Parking In Area Sq.Mt. - - 37.50 OK
TwoWheeler In Area Sq.Mt. - - 64.00 OK
Total TwoWheeler In Area Sq.Mt. 10.00 - 64.00 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 8.50 OK
PLOT - - - DRIVEWAY - Width No. 3.60 - 4.60 OK
A-1 (SRI ARJUN PRASAD ARYA) Front Margin... 12.1 MTR WIDE ROAD Access Road Mt. 9.00 - 9.30 OK
Rear Margin Mt. 6.00 - 6.00 OK
Side1 Margin Mt. 6.00 - 6.00 OK
Side2 Margin Mt. 6.00 - 10.80 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI ARJUN PRASAD ARYA) Height Mt. 23.10 4.50 OK
A (SRI ARJUN PRASAD ARYA) Ground Floor - Height Mt. 2.75 - 4.50 OK
Ground Floor - Clear Height Mt. 2.75 - 4.38 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 4.29 OK
Plinth - Height Mt. 0.45 - 0.65 OK
Plinth - Clear Height Mt. - - 0.65 OK
Plinth - Beam Clear Height Mt. - - 0.65 OK
A (SRI ARJUN PRASAD ARYA) Terrace Floor - Height Mt. - - 1.06 OK
Terrace Floor - Clear Height Mt. - - 1.06 OK
Terrace Floor - Beam Clear Height Mt. - - 1.06 OK
A (SRI ARJUN PRASAD ARYA) No. of Floors No. G + 6 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.150 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 15 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.150 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 3.175 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.90 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 1.21 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.94 OK
Width Mt. - - 1.13 OK
Depth Mt. - - 1.71 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.28 OK
Width Mt. - - 0.48 OK
Depth Mt. - - 2.69 OK
Height Mt. - - - OK
Area Sq.Mt. - - 1.28 OK
Width Mt. - - 0.48 OK
Depth Mt. - - 2.69 OK
Height Mt. - - - OK
GUARD ROOM Area Sq.Mt. - 10.00 4.00 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 2.00 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.71 OK
Width Mt. - - 1.00 OK
Depth Mt. - - 1.71 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 6.81 OK
Width Mt. - - 1.78 OK
Depth Mt. - - 3.82 OK
Height Mt. - - - OK
A (SRI ARJUN PRASAD ARYA) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Chatra Nagar Prishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Chatra Nagar Prishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(7) No need to check distance from Building GUARD ROOM
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
(10) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(11) No need to check distance from Building Generator Room
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)