No Image Found   

Detail Scrutiny Report

Chaibasa Nagar Parshad

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 07-10-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictWEST SINGHBHUM
AuthorityCHAIBASA NAGAR PARISHAD
Inward_NoCNP/BP/0025/W05/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBakurndaj Tola
Taluka20
Layout Sanction Date28/11/2002
Architect Details
Architect NameSAQUIB JAWED
License No.CNP/ENG/0007/2021
Architect AddressDream home solution, Vaishnav sai apartment, near 501 bidi factory, kusum kunj more, bangali tola, chakradharpur
Architect EmailIDsaquibjawed11@gmail.com
Architect Mobile No7050912303
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1257 A (OLD), 179 A (NEW)
NorthPlot No. - NIJ
SouthPlot No. - NIJ
EastRoad Width - 9
WestPlot No. - NIJ
Owner's Details
NameMR.BASAR NAWAZ AND BROTHERS
AddressAT- BARQUANDAJ TOLA, CHAIBASA
Email IDsaquibjawed11@gmail.com
Mobile No9199270176
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 242.81
2 Plot area as per Document by Applicant 242.81
3 Physical area measured at site 242.81
4 Area as per Site Visit (Site Visit Report) 242.81
5Area as per Drawing 242.81

Area of Plot Considered : 242.81

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 242.81
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 242.81
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 225.80
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 17.01
17.01
Balance Plot Area 225.80

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 145.69
Proposed Coverage Area ( 51.59 % ) 125.27
Total Prop. Coverage Area ( 51.59 % ) 125.27
Balance coverage area ( 8.41 % ) 20.42
FAR CHECK
Perm. FAR Area ( 2.000 ) 485.62
Total Perm. FAR area 485.62
Residential FAR 478.17
Proposed FAR Area 478.17
Total Proposed FAR Area 478.17
Consumed FAR (Factor) 1.97
Balance FAR Area 7.45
BUA CHECK
Total Proposed BuiltUp Area 501.08


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 9 6.20
Proposed Road Width as per Master Plan 9 -
Road Widening Width 0 -
Plot size (as per measurement) 242.81 242.81

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 12.14 17.01 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 17.01 0.00 0.00 - 1.32 - 79.76 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 9 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENTIAL) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENTIAL) 12.30 12.65 12.65 12.65 Failed


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Third Floor 2.75 - 3.16 2.75 - 3.05 2.40 - 2.91 OK
Second Floor 2.75 - 3.16 2.75 - 3.05 2.40 - 2.91 OK
First Floor 2.75 - 3.16 2.75 - 3.05 2.40 - 2.91 OK
Ground Floor 2.75 - 3.16 2.75 - 3.05 2.40 - 2.91 OK
Plinth 0.45 - 0.46 - - 0.46 - - 0.46 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Terrace Floor - - 1.06 - - 1.06 - - 1.06 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENTIAL) G + 4 4 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
145.69 125.27 OK
60% 51.59%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENTIAL) - 125.27
  Total Prop. Coverage Area - 125.27
  Total Coverage Area 145.69 125.27

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Resi.
A (RESIDENTIAL) 1 501.08 125.27 375.81 22.92 119.54 358.62 478.16 478.16 01
Grand Total : 1 501.08 125.27 375.81 22.92 119.54 358.62 478.16 478.16 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENTIAL)
Proposed Built Up Area (Sq.mt.) Existing Built up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Existing FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total Existing Built up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Existing FAR Area (Sq.mt.)
Ground Floor 0.00 125.27 0.00 119.54 0.00 125.27 0.00 119.54
First Floor 125.27 0.00 119.54 0.00 125.27 0.00 119.54 0.00
Second Floor 125.27 0.00 119.54 0.00 125.27 0.00 119.54 0.00
Third Floor 125.27 0.00 119.54 0.00 125.27 0.00 119.54 0.00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 375.81 125.27 358.62 119.54 375.81 125.27 358.62 119.54


[-] UnitBUA Table for Building :A (RESIDENTIAL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type Entity Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT 1 FLAT Existing 409.65 407.72 8 1
TYPICAL - 1, 2& 3 FLOOR PLAN SPLIT 1 FLAT Proposed 0.00 0.00 7 0
Total: - - - 409.65 407.72 29 1


[-] Building :A (RESIDENTIAL)
Floor Name Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Resi.
Ground Floor 125.27 125.27 0.00 5.73 119.54 0.00 119.54 119.54 01
First Floor 125.27 0.00 125.27 5.73 0.00 119.54 119.54 119.54 00
Second Floor 125.27 0.00 125.27 5.73 0.00 119.54 119.54 119.54 00
Third Floor 125.27 0.00 125.27 5.73 0.00 119.54 119.54 119.54 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 501.08 125.27 375.81 22.92 119.54 358.62 478.16 478.16 01
Total Number of Same Buildings : 1
Total : 501.08 125.27 375.81 22.92 119.54 358.62 478.16 478.16 01
[-] Table 4c-2

  FAR Area
Building FAR Area:478.17
Existing FAR Area :0.00
Perm.
485.62
Prop.
478.17
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENTIAL) 6.2 METER WIDE MAIN ROAD 3.00 3.00 1.80 1.80 0.90 0.90 0.90 0.90 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (RESIDENTIAL)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENTIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
TERRACE FLOOR PLAN STAIRCASE - 1.067 - 0.254 - 0.000 - 0 - - 2.400 OK
TYPICAL - 1, 2& 3 FLOOR PLAN STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.132 - 12 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 0.60 - - 0.66 - - 0.92 - - 0.00 OK
SUMP TANK - - 0.37 - - 0.61 - - 0.61 - - 0.00 OK
RAIN WATER HARVESTING - - 0.61 - - 0.58 - - 1.07 - - 0.00 OK
Entrance Lobby - 12.00 5.73 - - 1.22 - - 4.70 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENTIAL) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENTIAL)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Floor:TYPICAL - 1, 2& 3 FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT 1 KITCHEN 4.33X3.51 5.00 15.18 1.80 3.51 1.80 4.33 1.52 1.44 Failed


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 242.81 OK
  Plot Width - 13.26 OK
  Plot Depth - 18.31 OK
  Access Width - 6.20 OK
  Plot Frontage - 14.94 OK
  Coverage Area 145.69 125.27 OK
  FAR Area
Bldg. FAR Area : 478.17
Sanctioned FAR Area :0.00
485.62 478.17 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Chaibasa Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Chaibasa Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(8) No need to check distance from Building Entrance Lobby
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)