No Image Found

Detail Scrutiny Report

Dumka Nagar Parishad

Version Number: 1.0.11
Version Date: 04/05/2017
Report Generated On: 03-06-2017

General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDUMKA
AuthorityDUMKA NAGAR PARISHAD
Inward_NoDNP/BP/0001/W16/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDumka Town
Taluka21
Architect Details
Architect NamekKRISHNA NANDAN SINGH
License No.DNP/ENG/0001/2017
Architect AddressNIDHI NIWASH, THANA ROAD, DUMKA
Architect EmailIDknsingdmk@rediffmail.com
Architect Mobile No9431367672
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No18
NorthPlot No. - 19
SouthRoad Width - 6.40
EastRoad Width - 4.25
WestPlot No. - 19
Owner's Details
NameSRI RAMESH KUMAR SINGH SRI RAMADHIR SINGH SRI KRISHNA NAND SINGH AND SRI ANIL KUMAR SINGH
AddressSINGH BHAWAN, NEAR HADHADIYA PUL, BHAGALPUR ROAD, DUMKA
Email IDrameshkumarsingh465@gmail.com
Mobile No9431154583
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 618.95
2 Plot area as per Document by Applicant 600.56
3 Physical area measured at site 600.56
4 Area as per Site Visit (Site Visit Report) 600.56
5Area as per Drawing 600.56

Area of Plot Considered : 600.56

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 600.56
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 600.56
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 538.55
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 62.01
62.01
Balance Plot Area 538.55

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 360.34
Proposed Coverage Area ( 43.65 % ) 262.12
Total Prop. Coverage Area ( 43.65 % ) 262.12
Balance coverage area ( 16.35 % ) 98.22
FAR CHECK
Perm. FAR Area ( 2.00 ) 1201.12
Total Perm. FAR area 1201.12
Residential FAR 1146.79
Proposed FAR Area 1166.99
Total Proposed FAR Area 1166.99
Consumed FAR (Factor) 1.94
Balance FAR Area 34.13
BUA CHECK
Total Proposed BuiltUp Area 1447.16


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 6.4 6.40
Proposed Road Width as per Master Plan 6.4 -
Road Widening Width 1 -
Plot size (as per measurement) 600.56 -




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 60.06 62.01 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 62.01 0.00 0.00 - 2.99 - 89.26 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 9 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 14.50 14.38 14.38 14.38 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BUILDING) Fourth Floor 2.75 - 2.88 OK
Third Floor 2.75 - 2.88 OK
Second Floor 2.75 - 2.88 OK
First Floor 2.75 - 2.88 OK
Ground Floor 2.75 - 2.88 OK
Plinth - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BUILDING) Terrace Floor 1.00 1.20 1.00 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) P + 4 5 - 16 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
360.34 262.12 OK
60% 43.65%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (BUILDING) - 262.12
Total Prop. Coverage Area - 262.12
Total Coverage Area 360.34 262.12


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Void Parking Resi. Stair
A (BUILDING) 1 1447.16 12.92 25.32 241.92 1146.80 16.97 1167.00 1167.00 16
Grand Total : 1 1447.16 12.92 25.32 241.92 1146.80 16.97 1167.00 1167.00 16.00


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 262.12 20.20 262.12 20.20
First Floor 296.26 286.70 296.26 286.70
Second Floor 296.26 286.70 296.26 286.70
Third Floor 296.26 286.70 296.26 286.70
Fourth Floor 296.26 286.70 296.26 286.70
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1447.16 1167.00 1447.16 1167.00


[-] Buildingwise Tenement/Unit Details
Floor Name Building Name
A (BUILDING)
Tenement/Unit Name Tenement/Unit Area
FIRST FLOOR UNIT-1 70.16
UNIT-4 46.37
UNIT-3 65.25
UNIT-2 68.43
SECOND FLOOR UNIT-1 70.16
UNIT-4 46.37
UNIT-3 65.25
UNIT-2 68.43
THIRD FLOOR UNIT-1 70.16
UNIT-4 46.37
UNIT-3 65.25
UNIT-2 68.43
FOURTH FLOOR UNIT-1 70.16
UNIT-4 46.37
UNIT-3 65.25
UNIT-2 68.43
Total : 16 1000.83


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Void Parking Resi. Stair
Ground Floor 262.12 0.00 0.00 241.92 0.00 16.97 20.20 20.20 00
First Floor 296.26 3.23 6.33 0.00 286.70 0.00 286.70 286.70 04
Second Floor 296.26 3.23 6.33 0.00 286.70 0.00 286.70 286.70 04
Third Floor 296.26 3.23 6.33 0.00 286.70 0.00 286.70 286.70 04
Fourth Floor 296.26 3.23 6.33 0.00 286.70 0.00 286.70 286.70 04
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1447.16 12.92 25.32 241.92 1146.80 16.97 1167.00 1167.00 16
Total Number of Same Buildings : 1
Total : 1447.16 12.92 25.32 241.92 1146.80 16.97 1167.00 1167.00 16

[-] Table 4c-2

FARArea
Building FAR Area:1166.99
Existing FAR Area :0.00
Perm.
1201.12
Prop.
1166.99
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 6.4 METER WIDE MAIN ROAD 3.00 4.90 3.00 3.00 3.00 3.00 3.00 3.00 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Status
A-1 (BUILDING) BldgLine for 6.4 METER WIDE MAIN ROAD 0.55 4.90 Ok






[-] Inner Building Details (Table 6)


[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Status
Prop Reqd Prop
A (BUILDING) 14.38 1 1 OK

[-] Lift Check Table

[-] For Building :A (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
TYPICAL - 1- 4 FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.91 1.90 2.08 OK




[-] Parking Details (Table 7)

[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car
Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Residential Residential Bldg/Apartment > 0 1 16.00 1 16 -
Total : - - - - 16 0

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car 16 184.32 0 0.00
Other Parking - - - 241.92
Total 184.32 241.92 OK

Individual Parking Checks (Table 7c)

Individual Vehicle Parking is not provided


Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE - 1.149 - 0.250 - 0.144 - 10 - - 0.000 OK
TYPICAL - 1- 4 FLOOR PLAN STAIRCASE - 1.149 - 0.250 - 0.144 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.149 - 0.250 - 0.000 - 0 - - 2.380 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 2.88 - - 1.20 - - 2.40 - - 0.00 OK
SUMP TANK - - 15.00 - - 3.00 - - 5.00 - - 0.00 OK
RAIN WATER HARVESTING - - 5.54 - - 1.93 - - 2.87 - - 0.00 OK
ENT.GATE - - 0.63 - - 0.13 - - 5.00 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK




[-] Floor Details (Table 9)


[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:TYPICAL - 1- 4 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 600.56 OK
Plot Width - 29.72 OK
Plot Depth - 20.21 OK
Access Width 6.10 6.40 OK
Plot Frontage - 32.00 OK
Coverage Area 360.34 262.12 OK
FARArea
Bldg. FAR Area : 1166.99
Sanctioned FAR Area :0.00
1201.12 1166.99 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Parking Check FOR POPULATION UPTO 150000 AND RESIDENTIAL USE MULTIFAMILY BUILDING, ONE SPACE FOR EVERY ONE APARTMENT OR PART THERE OF. {AS PER RULE NO. 23 TABLE NO. 7}
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 15-21 mt. and Plot width 27-33 mt., Margin required in Front shall be 3.0 mt., Rear 3.0 mt. and 3.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only Stilt + 4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building above 12.0 mt. Height and G + 4 and above floors, Mini. 1 Lift shall be required. {As per Rule No. 49.1.2}
Lift (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building above 12.0 mt. Height and G + 4 and above floors, Mini. 1 Lift shall be required. {As per Rule No. 49.1.2}
StairCase (1) No Rule Defined
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)