No Image Found

Detail Scrutiny Report

Dumka Nagar Parishad

Version Number: 1.0.14
Version Date: 11/07/2017
Report Generated On: 01-08-2017

General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDUMKA
AuthorityDUMKA NAGAR PARISHAD
Inward_NoDNP/BP/0002/W05/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDumka Town
Taluka21
Architect Details
Architect NameSARAT CHANDRA PANJIYARA
License No.DNP/SUP/0002/2016
Architect AddressDANGALPARA, KANOOPARA, HIZLA ROAD,DUMKA
Architect EmailIDsaratdmk@rediffmail.com
Architect Mobile No7250788612
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No507 part
NorthPlot No. - 507
SouthPlot No. - 507
EastRoad Width - 6.10
WestPlot No. - 507
Owner's Details
NameRAJENDRA PD SAH
AddressBABUPARA DUMKA
Email IDkumar.chandan975@gmail.com
Mobile No9334611331
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 97.02
2 Plot area as per Document by Applicant 80.84
3 Physical area measured at site 80.84
4 Area as per Site Visit (Site Visit Report) 80.84
5Area as per Drawing 80.84

Area of Plot Considered : 80.84

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 80.84
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 80.84
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 71.84
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 9.00
9.00
Balance Plot Area 71.84

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 56.59
Proposed Coverage Area ( 62.22 % ) 50.30
Total Prop. Coverage Area ( 62.22 % ) 50.30
Balance coverage area ( 7.78 % ) 6.29
FAR CHECK
Perm. FAR Area ( 2.50 ) 202.10
Total Perm. FAR area 202.10
Residential FAR 100.60
Proposed FAR Area 100.60
Total Proposed FAR Area 100.60
Consumed FAR (Factor) 1.24
Balance FAR Area 101.50
BUA CHECK
Total Proposed BuiltUp Area 100.60


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road -
Existing Road Width 6.1 6.40
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0.1 -
Plot size (as per measurement) 80.84 -




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 8.08 9.00 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 9.00 0.00 0.00 - 2.12 - 88.74 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENCIAL) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENCIAL) 12.10 6.00 6.00 6.00 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENCIAL) First Floor 2.75 - 3.00 OK
Ground Floor 2.75 - 3.00 OK
Plinth - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENCIAL) Terrace Floor 1.00 1.20 1.00 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENCIAL) P + 4 2 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
56.59 50.30 OK
70% 62.22%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (RESIDENCIAL) - 50.30
Total Prop. Coverage Area - 50.30
Total Coverage Area 56.59 50.30


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (RESIDENCIAL) 1 100.60 100.60 100.60 100.60 01
Grand Total : 1 100.60 100.60 100.60 100.60 1.00


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENCIAL)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 50.30 50.30 50.30 50.30
First Floor 50.30 50.30 50.30 50.30
Terrace Floor 0.00 0.00 0.00 0.00
Total : 100.60 100.60 100.60 100.60


[-] Buildingwise Tenement/Unit Details
Floor Name Building Name
A (RESIDENCIAL)
Tenement/Unit Name Tenement/Unit Area
GROUND FLOOR SPLIT UNIT-1 63.12
FIRST FLOOR SPLIT UNIT-1 0.00
Total : 1 63.12


[-] Building :A (RESIDENCIAL)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 50.30 50.30 50.30 50.30 01
First Floor 50.30 50.30 50.30 50.30 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 100.60 100.60 100.60 100.60 01
Total Number of Same Buildings : 1
Total : 100.60 100.60 100.60 100.60 01

[-] Table 4c-2

FARArea
Building FAR Area:100.60
Existing FAR Area :0.00
Perm.
202.10
Prop.
100.60
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENCIAL) 6.4 MTR WIDE ROAD 2.50 2.50 1.50 1.50 1.00 0.90 1.00 0.00 Failed







[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (RESIDENCIAL)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENCIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.750 1.100 0.225 0.250 0.200 0.107 - 13 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.750 1.100 0.225 0.250 0.200 0.107 - 13 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 1.100 - 0.250 - 0.000 - 0 2.100 - 2.400 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 0.75 - - 0.52 - - 1.44 - - 0.00 OK
SUMP TANK - - 0.60 - - 0.42 - - 1.44 - - 0.00 OK
RAIN WATER HARVESTING - - 0.80 - - 0.55 - - 1.47 - - 0.00 OK






[-] Floor Details (Table 9)


[-] Building:A (RESIDENCIAL)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 80.84 OK
Plot Width - 4.42 OK
Plot Depth - 18.29 OK
Access Width - 6.40 OK
Plot Frontage - 4.42 OK
Coverage Area 56.59 50.30 OK
FARArea
Bldg. FAR Area : 100.60
Sanctioned FAR Area :0.00
202.10 100.60 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only Stilt + 4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)