General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDUMKA
AuthorityDUMKA NAGAR PARISHAD
Inward_NoDNP/BP/0009/W16/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDumka Town
Taluka21
Architect Details
Architect NamekKRISHNA NANDAN SINGH
License No.DNP/ENG/0001/2017
Architect AddressNIDHI NIWASH, THANA ROAD, DUMKA
Architect EmailIDknsingdmk@rediffmail.com
Architect Mobile No9431367672
Plot Details
Plot Use Commercial
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No1663
NorthRoad Width - 9.0
SouthRoad Width - 12.00
EastPlot No. - 1664
WestPlot No. - 1662
Owner's Details
NameSRI RAJNANDAN PRASAD
AddressNORTH GANDHI MAIDAN , DUMKA,JHARKHAND
Email IDnandanvivek@rediffmail.com
Mobile No8292645358
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 602.23
2 Plot area as per Document by Applicant 602.07
3 Physical area measured at site 602.07
4 Area as per Site Visit (Site Visit Report) 602.07
5Area as per Drawing 602.07

Area of Plot Considered : 602.07

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse ResiComm Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 602.07
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 602.07
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 538.69
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 63.37
63.37
Balance Plot Area 538.69

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 301.04
Proposed Coverage Area ( 43.68 % ) 262.99
Total Prop. Coverage Area ( 43.68 % ) 262.99
Balance coverage area ( 6.32 % ) 38.05
FAR CHECK
Perm. FAR Area ( 2.50 ) 1505.18
Total Perm. FAR area 1505.18
Residential FAR 788.82
Commercial FAR 231.50
Special FAR 250.48
Proposed FAR Area 1283.28
Total Proposed FAR Area 1283.28
Consumed FAR (Factor) 2.13
Balance FAR Area 221.90
BUA CHECK
Total Proposed BuiltUp Area 1770.02


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 602.07 602.07


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 602.07 OK
Plot Width Sq.Mt. - - 14.83 OK
Plot Depth Sq.Mt. - - 40.59 OK
Access Width Sq.Mt. 6.10 - 12.00 OK
Plot Frontage Sq.Mt. - - 16.92 OK
Coverage Area Sq.Mt. - 301.04 262.99 OK
FAR Area Sq.Mt. - 1505.18 1283.28 OK
Consumed FAR Sq.Mt. - 2.50 2.13 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 60.21 63.37 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 63.37 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.78 OK
Tree Cover (Plantation) - Angle Degree - 84.60 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 9 OK
Car In Area Sq.Mt. - - 125.00 OK
Total Car In Area Sq.Mt. 125.00 - 125.00 OK
Visitor's Car Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. 30.00 - 30.00 OK
Other Parking In Area Sq.Mt. - - 106.58 OK
A-1 (COMMERCIAL) Front Margin... 12 METER WIDE MAIN ROAD Mt. 5.00 - 7.50 OK
Rear Margin Mt. 4.50 - 4.50 OK
Side1 Margin Mt. 2.00 - 2.50 OK
Side2 Margin Mt. 2.00 - 2.50 OK
A-1 (COMMERCIAL) Basement Front Margin... 12 METER WIDE MAIN ROAD Mt. 3.00 - 7.50 OK
Basement Rear Margin Mt. 3.00 - 4.50 OK
Basement Side1 Margin Mt. 2.00 - 2.50 OK
Basement Side2 Margin Mt. 2.00 - 2.50 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (COMMERCIAL) Height Mt. 23.10 14.30 OK
A (COMMERCIAL) Fourth Floor - Height Mt. 2.75 - 2.86 OK
Third Floor - Height Mt. 2.75 - 2.86 OK
Second Floor - Height Mt. 2.75 - 2.86 OK
First Floor - Height Mt. 2.75 - 2.86 OK
Ground Floor - Height Mt. 2.75 - 2.86 OK
Basement Floor - Height Mt. 2.40 - 2.50 OK
A (COMMERCIAL) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (COMMERCIAL) Basement Floor - Height Below GL Mt. - 1.90 OK
Basement Floor - Area Sq.Mt. - 276.34 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (COMMERCIAL) Area Sq.Mt. - 276.34 OK
Status - OK
Total Area Sq.Mt. - 276.34 OK
A (COMMERCIAL) No. of Basement Floor No. 1 1 OK
A (COMMERCIAL) No. of Floors No. G + 6 5 OK
No. of Tenements No. - 6 OK
A (COMMERCIAL) TYPICAL - 2- 4 FLOOR PLAN - BALCONY - Width Mt. 0.90 0.40 OK
TYPICAL - 2- 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 1.03 OK
TYPICAL - 2- 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.41 OK
TYPICAL - 2- 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.39 OK
TYPICAL - 2- 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.41 OK
TYPICAL - 2- 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.41 OK
TYPICAL - 2- 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.42 OK
TYPICAL - 2- 4 FLOOR PLAN - BALCONY - Width Mt. 0.90 0.40 OK
A (COMMERCIAL) GROUND FLOOR PLAN - Passage Name - OK
GROUND FLOOR PLAN - Width Mt. 1.00 3.56 OK
GROUND FLOOR PLAN - Length Mt. - 7.60 OK
A (COMMERCIAL) Number Of Lift(s) No. 1 2 OK
A (COMMERCIAL) BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 2.15 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 2.41 OK
BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 2.40 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 2.15 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.41 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.40 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 2.15 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 2.41 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 2.40 OK
TYPICAL - 2- 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.91 OK
TYPICAL - 2- 4 FLOOR PLAN - Lift - Depth Mt. 1.90 2.40 OK
TYPICAL - 2- 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
TYPICAL - 2- 4 FLOOR PLAN - Lift - Depth Mt. 1.90 2.40 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.91 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.40 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.40 OK
BASEMENT FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.143 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.143 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 2- 4 FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.143 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Fire Escape Staircase - Flight Width Mt. - 1.200 OK
Fire Escape Staircase - Tread Width Mt. - 0.250 OK
Fire Escape Staircase - Riser Height Mt. - - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - 2.150 OK
STAIRCASE - Flight Width Mt. - 1.200 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.150 OK
Toilet Area Sq.Mt. - 5.00 3.09 OK
Width Mt. - - 1.30 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.09 OK
Width Mt. - - 1.30 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.03 OK
Width Mt. - - 0.46 OK
Depth Mt. - - 2.25 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 3.60 OK
Width Mt. - - 0.22 OK
Depth Mt. - - 16.09 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 6.24 OK
Width Mt. - - 1.60 OK
Depth Mt. - - 3.90 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.03 OK
Width Mt. - - 0.46 OK
Depth Mt. - - 2.25 OK
Height Mt. - - - OK
A (COMMERCIAL) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 19.00 mt. long 1.90 mt. High 4.50 mt. Wide Car Ramp - Width Mt. 4.50 4.50 OK
19.00 mt. long 1.90 mt. High 4.50 mt. Wide Car Ramp - Depth Mt. 1.00 1.90 OK
19.00 mt. long 1.90 mt. High 4.50 mt. Wide Car Ramp - Slope Ratio 1.00 : 10.00 - 01 : 10 OK
Ramp No. A (COMMERCIAL) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 39-45 mt. and Plot width 10-15 mt., Margin required in Front shall be 5.0 mt., Rear 4.5 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) No rule found for Mini. reqd Floor height
(4) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony (1) Projected balcony shall be allowed with a width of 0.9 meters where the setback is between 2.0 meters to 2.5 meters {As per Rule No. 46.4}
(2) For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, upto G+4 floors or if the number of flats is upto 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
(5) No Rule Defined
(6) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(7) No Rule Defined
(8) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)