No Image Found

Check List Report

Dumka Nagar Parishad

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 28-11-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District DUMKA
Authority DUMKA NAGAR PARISHAD
Inward_No DNP/BP/0010/W20/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Dumka Town
Taluka 21
Architect Details
Architect Name kKRISHNA NANDAN SINGH
License No. DNP/ENG/0001/2017
Architect Address NIDHI NIWASH, THANA ROAD, DUMKA
Architect EmailID knsingdmk@rediffmail.com
Architect Mobile No 9431367672
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 1644 PART
North Plot No. - 1644 PART
South Plot No. - 1644 PART
East Road Width - 4.82
West Road Width - 4.81
Owner's Details
Name SMT SHILA DEVI HIMMATSINGHKA
Address C/O SRI MOHAN KUMAR HIMMATSINGHKA SHYAM BAZAR ROAD, DUMKA
Email ID jsharmadmk@gmail.com
Mobile No 6206827190
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 816.35
2 Plot area as per Document by Applicant 816.30
3 Physical area measured at site 816.30
4 Area as per Site Visit (Site Visit Report) 816.30
5 Area as per Drawing 816.30

Area of Plot Considered : 816.30

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 816.30
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 816.30
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 687.61
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 128.69
128.69
Balance Plot Area 687.61

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 489.78
Proposed Coverage Area ( 46.09 % ) 376.20
Total Prop. Coverage Area ( 46.09 % ) 376.20
Balance coverage area ( 13.91 % ) 113.58
FAR CHECK
Perm. FAR Area ( 1.80 ) 1469.34
Total Perm. FAR area 1469.34
Residential FAR 1212.83
Proposed FAR Area 1222.82
Total Proposed FAR Area 1222.82
Consumed FAR (Factor) 1.50
Balance FAR Area 246.52
BUA CHECK
Total Proposed BuiltUp Area 1652.02


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.82 4.82
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 816.3 816.30


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 816.30 OK
Plot Width Sq.Mt. - - 18.14 OK
Plot Depth Sq.Mt. - - 45.00 OK
Access Width Sq.Mt. - - 4.82 OK
Plot Frontage Sq.Mt. - - 18.14 OK
Coverage Area Sq.Mt. - 489.78 376.20 OK
FAR Area Sq.Mt. - 1469.34 1222.82 OK
Consumed FAR Sq.Mt. - 1.80 1.50 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 81.63 128.69 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 128.69 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.90 OK
Tree Cover (Plantation) - Angle Degree - 89.85 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 4 OK
Car In Area Sq.Mt. - - 112.50 OK
Total Car In Area Sq.Mt. 112.50 - 112.50 OK
Visitor's Car Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. 18.00 - 20.00 OK
Other Parking In Area Sq.Mt. - - 241.41 OK
A-1 (RESIDENTIAL) Front Margin... 4.82 METER WIDE MAIN ROAD Mt. 4.00 - 7.50 OK
Rear Margin Mt. 4.00 - 4.50 OK
Side1 Margin Mt. 1.00 - 2.64 OK
Side2 Margin Mt. 1.00 - 4.10 OK
A-1 (RESIDENTIAL) Basement Front Margin... 4.82 METER WIDE MAIN ROAD Mt. 3.00 - 7.50 OK
Basement Rear Margin Mt. 3.00 - 4.50 OK
Basement Side1 Margin Mt. 1.00 - 2.64 OK
Basement Side2 Margin Mt. 1.00 - 4.10 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL) Height Mt. 10.00 8.58 OK
A (RESIDENTIAL) Second Floor - Height Mt. 2.75 - 2.86 OK
First Floor - Height Mt. 2.75 - 2.86 OK
Ground Floor - Height Mt. 2.75 - 2.86 OK
Basement Floor - Height Mt. 2.40 - 2.50 OK
A (RESIDENTIAL) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (RESIDENTIAL) Basement Floor - Height Below GL Mt. - 1.72 OK
Basement Floor - Area Sq.Mt. - 376.20 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (RESIDENTIAL) Area Sq.Mt. - 376.20 OK
Status - OK
Total Area Sq.Mt. - 376.20 OK
A (RESIDENTIAL) No. of Basement Floor No. 2 1 OK
A (RESIDENTIAL) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 9 OK
A (RESIDENTIAL) Number Of Lift(s) No. - 1 OK
A (RESIDENTIAL) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 2.00 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.40 OK
BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 2.00 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 2.40 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Width Mt. 1.70 2.00 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Depth Mt. 1.90 2.40 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.00 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.40 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.130 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.130 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.03 OK
Width Mt. - - 1.61 OK
Depth Mt. - - 1.61 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 2.18 OK
Width Mt. - - 0.34 OK
Depth Mt. - - 6.44 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 11.07 OK
Width Mt. - - 2.40 OK
Depth Mt. - - 4.61 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.19 OK
Width Mt. - - 1.35 OK
Depth Mt. - - 5.33 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 10.86 OK
Width Mt. - - 2.40 OK
Depth Mt. - - 4.53 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.24 OK
Width Mt. - - 1.18 OK
Depth Mt. - - 1.90 OK
Height Mt. - - - OK
A (RESIDENTIAL) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 13.50 mt. long 1.80 mt. High 4.50 mt. Wide Car Ramp - Width Mt. 4.50 4.50 OK
13.50 mt. long 1.80 mt. High 4.50 mt. Wide Car Ramp - Depth Mt. 1.00 1.80 OK
13.50 mt. long 1.80 mt. High 4.50 mt. Wide Car Ramp - Slope Ratio 1.00 : 7.00 - 01 : 08 OK
Ramp No. A (RESIDENTIAL) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 15-21 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 12.0 mt., for every 16 flats or upto G+4 floors, No Lift is reqd. {As per Rule No. 49.1.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(5) No need to check distance from Building Entrance Lobby
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)