-
No Image Found

Failed List Report

Dumka Nagar Parishad

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 07-12-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District DUMKA
Authority DUMKA NAGAR PARISHAD
Inward_No DNP/BP/0011/W18/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Dumka Town
Taluka 21
Architect Details
Architect Name kKRISHNA NANDAN SINGH
License No. DNP/ENG/0001/2017
Architect Address NIDHI NIWASH, THANA ROAD, DUMKA
Architect EmailID knsingdmk@rediffmail.com
Architect Mobile No 9431367672
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 930
North Plot No. - 930
South Plot No. - 930 DRAIN
East Road Width - 10.75
West Plot No. - 930
Owner's Details
Name SANJAY KUMAR GUPTA
Address DANGALPARA HIZLA ROAD DUMKA
Email ID sanjaydcbsf@gmail.com
Mobile No 9431310398
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 244.23
2 Plot area as per Document by Applicant 157.01
3 Physical area measured at site 157.01
4 Area as per Site Visit (Site Visit Report) 157.01
5 Area as per Drawing 157.01

Area of Plot Considered : 157.01

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 157.01
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 157.01
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 141.03
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 15.98
15.98
Balance Plot Area 141.03

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 109.91
Proposed Coverage Area ( 48.84 % ) 76.68
Total Prop. Coverage Area ( 48.84 % ) 76.68
Balance coverage area ( 21.16 % ) 33.23
FAR CHECK
Perm. FAR Area ( 2.50 ) 392.52
Total Perm. FAR area 392.52
Residential FAR 230.03
Proposed FAR Area 230.03
Total Proposed FAR Area 230.03
Consumed FAR (Factor) 1.47
Balance FAR Area 162.49
BUA CHECK
Total Proposed BuiltUp Area 230.04


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 10.75 10.75
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 157.01 157.01





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)