-
No Image Found   

Check List Report

Dumka Nagar Parishad

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 03-02-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDUMKA
AuthorityDUMKA NAGAR PARISHAD
Inward_NoDNP/BP/0011/W16/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDumka Town
Taluka21
Architect Details
Architect NameSURJYA CHOUDHURY
License No.DNP/ENG/0002/2018
Architect Address17,ARAVIND PATH,KADMA
Architect EmailIDz.markinteriors@gmail.com
Architect Mobile No8987491835
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No654 & 655
NorthPlot No. - PUNITA KUMARI
SouthRoad Width - 6.10 MTR
EastPlot No. - AVINASH BAKSHI
WestPlot No. - SANJAY KUMAR CHOUDHARY
Owner's Details
NameAJIT KUMAR DARUKA
AddressBAKSHI BANDH ROAD
Email IDbarundaruka@gmail.com
Mobile No9006555396
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 167.08
2 Plot area as per Document by Applicant 167.08
3 Physical area measured at site 167.08
4 Area as per Site Visit (Site Visit Report) 167.08
5Area as per Drawing 167.08

Area of Plot Considered : 167.08

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 167.08
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 167.08
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 149.30
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 17.78
17.78
Balance Plot Area 149.30

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 116.96
Proposed Coverage Area ( 58.21 % ) 97.26
Total Prop. Coverage Area ( 58.21 % ) 97.26
Balance coverage area ( 11.79 % ) 19.70
FAR CHECK
Perm. FAR Area ( 2.50 ) 417.70
Total Perm. FAR area 417.70
Residential FAR 389.04
Proposed FAR Area 389.04
Total Proposed FAR Area 389.04
Consumed FAR (Factor) 2.33
Balance FAR Area 28.66
BUA CHECK
Total Proposed BuiltUp Area 389.04


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 167.08 167.08
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 167.08 OK
Plot Width Mt. - - 9.14 OK
Plot Depth Mt. - - 18.28 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 9.14 OK
Coverage Area Sq.Mt. - 116.96 97.26 OK
FAR Area Sq.Mt. - 417.70 389.04 OK
Consumed FAR Sq.Mt. - 2.50 2.33 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 8.35 17.78 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 17.78 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.25 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 20 OK
A-1 (SRI AJIT KUMAR) Front Margin... 6.10 MTR WIDE ROAD Access Road Mt. 2.50 - 3.04 OK
Rear Margin Mt. 1.50 - 1.88 OK
Side1 Margin Mt. - - 0.92 OK
Side2 Margin Mt. 0.90 - 0.94 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI AJIT KUMAR) Height Mt. 12.19 9.20 OK
A (SRI AJIT KUMAR) Second Floor - Height Mt. 2.75 - 3.07 OK
Second Floor - Clear Height Mt. 2.75 - 2.95 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.76 OK
First Floor - Height Mt. 2.75 - 3.07 OK
First Floor - Clear Height Mt. 2.75 - 2.95 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.76 OK
Ground Floor - Height Mt. 2.75 - 3.07 OK
Ground Floor - Clear Height Mt. 2.75 - 2.95 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.76 OK
Basement Floor - Height Mt. 2.40 - 3.07 OK
Basement Floor - Clear Height Mt. 2.40 - 2.95 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.76 OK
A (SRI AJIT KUMAR) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (SRI AJIT KUMAR) Basement Floor - Height Below GL Mt. - 3.07 OK
Basement Floor - Area Sq.Mt. - 97.26 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - 1.89 OK
A (SRI AJIT KUMAR) Area Sq.Mt. - 97.26 OK
Status - OK
Total Area Sq.Mt. - 97.26 OK
A (SRI AJIT KUMAR) No. of Basement Floor No. 1 1 OK
A (SRI AJIT KUMAR) No. of Floors No. G + 4 3 OK
No. of Tenements No. - 1 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.169 OK
STAIRCASE - Tread Width Mt. 0.250 0.307 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.169 OK
STAIRCASE - Tread Width Mt. 0.250 0.307 OK
STAIRCASE - Riser Height Mt. 0.200 0.153 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.169 OK
STAIRCASE - Tread Width Mt. 0.250 0.307 OK
STAIRCASE - Riser Height Mt. 0.200 0.153 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.169 OK
STAIRCASE - Tread Width Mt. - 0.307 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.453 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.169 OK
STAIRCASE - Tread Width Mt. 0.250 0.307 OK
STAIRCASE - Riser Height Mt. 0.200 0.153 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.90 OK
Width Mt. - - 0.72 OK
Depth Mt. - - 1.24 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.69 OK
Width Mt. - - 1.22 OK
Depth Mt. - - 1.39 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.32 OK
Width Mt. - - 0.42 OK
Depth Mt. - - 3.15 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.02 OK
Width Mt. - - 1.30 OK
Depth Mt. - - 1.56 OK
Height Mt. - - - OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)