-
No Image Found   

Check List Report

Dumka Nagar Parishad

Version Number: 1.0.53  
Version Date: 16/10/2020 
Report Generated On: 10-02-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDUMKA
AuthorityDUMKA NAGAR PARISHAD
Inward_NoDNP/BP/0014/W15/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDumka Town
Taluka21
Architect Details
Architect NameSURJYA CHOUDHURY
License No.DNP/ENG/0002/2018
Architect Address17,ARAVIND PATH,KADMA
Architect EmailIDz.markinteriors@gmail.com
Architect Mobile No8987491835
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No40/56
NorthPlot No. - PARTY LAND
SouthRoad Width - 4.26
EastPlot No. - NATWAR AGARWAL
WestPlot No. - 674
Owner's Details
NameBINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA.
AddressNAYA PARA RAMJIVAN BAGAN DUMKA
Email IDdeepakkhetan9349@gmail.com
Mobile No7004425026
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 371.37
2 Plot area as per Document by Applicant 371.37
3 Physical area measured at site 371.37
4 Area as per Site Visit (Site Visit Report) 371.37
5Area as per Drawing 370.54

Area of Plot Considered : 370.54

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 370.54
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 370.54
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 327.73
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 42.81
42.81
Balance Plot Area 327.73

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 222.32
Proposed Coverage Area ( 59.71 % ) 221.25
Total Prop. Coverage Area ( 59.71 % ) 221.25
Balance coverage area ( 0.29 % ) 1.07
FAR CHECK
Perm. FAR Area ( 1.50 ) 555.81
Total Perm. FAR area 555.81
Residential FAR 435.46
Proposed FAR Area 447.44
Total Proposed FAR Area 447.44
Consumed FAR (Factor) 1.21
Balance FAR Area 108.37
BUA CHECK
Total Proposed BuiltUp Area 663.76


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.26 4.26
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 371.37 370.54
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 370.54 OK
Plot Width Mt. - - 12.19 OK
Plot Depth Mt. - - 30.39 OK
Access Width Mt. - - 4.26 OK
Plot Frontage Mt. - - 12.19 OK
Coverage Area Sq.Mt. - 222.32 221.25 OK
FAR Area Sq.Mt. - 555.81 447.44 OK
Consumed FAR Sq.Mt. - 1.50 1.21 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 37.05 42.81 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 42.81 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.19 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 14 OK
Car In Area Sq.Mt. - - 62.50 OK
Total Car In Area Sq.Mt. 75.00 - 89.50 OK
Parallel Car In Area Sq.Mt. - - 27.00 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 13.50 OK
Parallel Visitor's Car Parking In Area Sq.Mt. - - 13.50 OK
TwoWheeler In Area Sq.Mt. - - 22.00 OK
Total TwoWheeler In Area Sq.Mt. 12.00 - 22.00 OK
Other Parking In Area Sq.Mt. - - 124.78 OK
A-1 (BINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA) Front Margin... 4.26 MTR WIDE MAIN ROAD Access Road Mt. 4.00 - 5.56 OK
Rear Margin Mt. 2.50 - 3.00 OK
Side1 Margin Mt. 0.90 - 1.03 OK
Side2 Margin Mt. 0.90 - 1.03 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA) Height Mt. 10.00 9.14 OK
A (BINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA) Second Floor - Height Mt. 2.75 - 3.05 OK
Second Floor - Clear Height Mt. 2.75 - 2.95 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.83 OK
First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.95 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.83 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Clear Height Mt. 2.75 - 2.95 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.83 OK
Plinth - Height Mt. 0.45 - 0.59 OK
Plinth - Clear Height Mt. - - 0.59 OK
Plinth - Beam Clear Height Mt. - - 0.59 OK
A (BINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA) Terrace Floor - Height Mt. 1.00 1.20 1.08 OK
A (BINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 6 OK
A (BINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (BINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.71 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.06 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Width Mt. 1.70 1.71 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Depth Mt. 1.90 2.06 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.96 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.36 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.991 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.991 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.991 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.438 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.91 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 1.19 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.76 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 1.47 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.84 OK
Width Mt. - - 0.48 OK
Depth Mt. - - 3.84 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.76 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 1.47 OK
Height Mt. - - - OK
A (BINOD PRASAD AGARWAL AND RENU DEVI BHUWANIA) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)