Detail Scrutiny Report

Dumka Nagar Parishad

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 02-02-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDUMKA
AuthorityDUMKA NAGAR PARISHAD
Inward_NoDNP/BP/0001/W12/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDumka Town
Taluka21
Architect Details
Architect NameUDIT RAJ
License No.DNP/ARC/0002/2021
Architect AddressBAXI BANDH ROAD (BHARTIA PATHSHALA) DUMKA , JHARKHAND 814101
Architect EmailIDar.uditthakur05@gmail.com
Architect Mobile No8285454336
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1391 PART
NorthPlot No. - 1391 PART
SouthPlot No. - 1391 PART
EastPlot No. - 1393
WestRoad Width - 7.9
Owner's Details
NameARUNA DEVI SALAMPURIA
AddressW/O NAGAR PRASAD SALAMPURIA, KULDEEP SINGH ROAD, DUMKA
Email IDsidh4udmk@gmail.com
Mobile No9534138176
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 287.73
2 Plot area as per Document by Applicant 285.20
3 Physical area measured at site 285.20
4 Area as per Site Visit (Site Visit Report) 286.06
5Area as per Drawing 285.20

Area of Plot Considered : 285.20

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 285.20
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 285.20
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 240.35
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 44.85
44.85
Balance Plot Area 240.35

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 171.12
Proposed Coverage Area ( 59.50 % ) 169.70
Total Prop. Coverage Area ( 59.5 % ) 169.70
Balance coverage area ( 0.50 % ) 1.42
FAR CHECK
Perm. FAR Area ( 2.500 ) 713.00
Total Perm. FAR area 713.00
Residential FAR 693.48
Proposed FAR Area 693.48
Total Proposed FAR Area 693.48
Consumed FAR (Factor) 2.43
Balance FAR Area 19.52
BUA CHECK
Total Proposed BuiltUp Area 727.01


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 7.9 7.90
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 286.06 285.20
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 14.26 44.85 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 44.85 0.00 0.00 - 3.99 - 89.32 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENTIAL) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENTIAL) 14.85 11.80 11.80 11.80 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Third Floor 2.75 - 2.95 2.75 - 2.83 2.40 - 2.55 OK
Second Floor 2.75 - 2.95 2.75 - 2.83 2.40 - 2.55 OK
First Floor 2.75 - 2.95 2.75 - 2.83 2.40 - 2.55 OK
Ground Floor 2.75 - 2.95 2.75 - 2.83 2.40 - 2.55 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENTIAL) G + 5 4 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
171.12 169.70 OK
60% 59.5%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENTIAL) - 169.70
  Total Prop. Coverage Area - 169.70
  Total Coverage Area 171.12 169.70

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Accessory Use Resi.
A (RESIDENTIAL) 1 727.01 9.69 23.85 693.47 693.47 693.47 01
Grand Total : 1 727.01 9.69 23.85 693.47 693.47 693.47 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENTIAL)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 169.70 169.70 169.70 169.70
First Floor 185.77 174.59 185.77 174.59
Second Floor 185.77 174.59 185.77 174.59
Third Floor 185.77 174.59 185.77 174.59
Terrace Floor 0.00 0.00 0.00 0.00
Total : 727.01 693.47 727.01 693.47


[-] UnitBUA Table for Building :A (RESIDENTIAL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 583.57 567.77 7 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 12 0
TYPICAL - 2& 3 FLOOR PLAN SPLIT A FLAT 0.00 0.00 10 0
Total: - - 583.57 567.77 39 1


[-] Building :A (RESIDENTIAL)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Accessory Use Resi.
Ground Floor 169.70 0.00 0.00 169.70 169.70 169.70 01
First Floor 185.77 3.23 7.95 174.59 174.59 174.59 00
Second Floor 185.77 3.23 7.95 174.59 174.59 174.59 00
Third Floor 185.77 3.23 7.95 174.59 174.59 174.59 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 727.01 9.69 23.85 693.47 693.47 693.47 01
Total Number of Same Buildings : 1
Total : 727.01 9.69 23.85 693.47 693.47 693.47 01
[-] Table 4c-2

  FAR Area
Building FAR Area:693.48
Existing FAR Area :0.00
Perm.
713.00
Prop.
693.48
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENTIAL) 7.90 METER WIDE ROAD 3.00 3.00 2.25 4.00 0.90 0.90 0.90 0.90 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (RESIDENTIAL) 11.80 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (RESIDENTIAL)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
FIRST FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
TYPICAL - 2& 3 FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.70 1.90 1.90 OK

   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (RESIDENTIAL)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENTIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.900 1.350 0.250 0.250 0.200 0.089 - 7 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.900 1.350 0.250 0.250 0.200 0.089 - 7 - - 0.000 OK
TYPICAL - 2& 3 FLOOR PLAN Staircase -3FL 0.900 1.350 0.250 0.250 0.200 0.089 - 7 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 1.350 - 0.250 - 0.000 - 0 - - 2.525 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RWH - - 0.30 - - 0.62 - - 0.62 - - 0.00 OK
ENT.GATE - - 0.45 - - 0.13 - - 3.60 - - 0.00 OK
Entrance Lobby - 12.00 7.95 - - 1.50 - - 5.30 - - 0.00 OK
Entrance Lobby - 12.00 7.95 - - 1.50 - - 5.30 - - 0.00 OK
SHS - - 0.42 - - 0.73 - - 0.73 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENTIAL) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENTIAL)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 2& 3 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 285.20 OK
  Plot Width - 10.97 OK
  Plot Depth - 26.00 OK
  Access Width - 7.90 OK
  Plot Frontage - 10.66 OK
  Coverage Area 171.12 169.70 OK
  FAR Area
Bldg. FAR Area : 693.48
Sanctioned FAR Area :0.00
713.00 693.48 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RWH
(3) No need to check distance from Building ENT.GATE
(4) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(5) No need to check distance from Building Entrance Lobby
(6) -
(7) No need to check distance from Building SHS
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)