No Image Found   

Detail Scrutiny Report

Dumka Nagar Parishad

Version Number: 1.0.69  
Version Date: 16/10/2020 
Report Generated On: 14-03-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDUMKA
AuthorityDUMKA NAGAR PARISHAD
Inward_NoDNP/BP/0005/W21/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBANDARJORI
Taluka21
Architect Details
Architect NameUDIT RAJ
License No.DNP/ARC/0002/2021
Architect AddressBAXI BANDH ROAD (BHARTIA PATHSHALA) DUMKA , JHARKHAND 814101
Architect EmailIDar.uditthakur05@gmail.com
Architect Mobile No8285454336
Plot Details
Plot Use Assembly
Plot SubUse Religious Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No6
NorthRoad Width - 18.29
SouthPlot No. - OTHER PLOT
EastPlot No. - OTHER PLOT
WestPlot No. - OTHER PLOT
Owner's Details
NameJULIUS MARANDI
AddressBISHOP CATHOLIC DIOCESE DUDHANI DUMKA
Email IDbspdumka@yahoo.co.in
Mobile No9304355877
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1559.00
2 Plot area as per Document by Applicant 1301.11
3 Physical area measured at site 1301.11
4 Area as per Site Visit (Site Visit Report) 1301.11
5Area as per Drawing 1300.89

Area of Plot Considered : 1300.89

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotCHURCH
Plot OccupancyAssembly
Plot SubUse Religious Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1300.89
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1300.89
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1091.32
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 209.57
209.57
Balance Plot Area 1091.32

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 650.45
Proposed Coverage Area ( 27.34 % ) 355.65
Total Prop. Coverage Area ( 27.34 % ) 355.65
Balance coverage area ( 22.66 % ) 294.80
FAR CHECK
Perm. FAR Area ( 2.250 ) 2927.00
Total Perm. FAR area 2927.00
Special FAR 711.30
Proposed FAR Area 711.30
Total Proposed FAR Area 711.30
Consumed FAR (Factor) 0.55
Balance FAR Area 2215.70
BUA CHECK
Total Proposed BuiltUp Area 711.30


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 18.29 18.29
Proposed Road Width as per Master Plan 18.29 -
Road Widening Width 0 -
Plot size (as per measurement) 1301.11 1300.89
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 130.09 209.57 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 209.57 0.00 0.00 - 6.88 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 9 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (CHURCH) Assembly Religious Building Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (CHURCH) 30.00 9.47 9.47 9.47 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (CHURCH) First Floor 2.75 - 6.48 2.75 - 4.70 2.40 - 4.41 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.71 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK




No Floor Found.
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (CHURCH) - 2 - 0 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
650.45 355.65 OK
50% 27.34%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (CHURCH) - 355.65
  Total Prop. Coverage Area - 355.65
  Total Coverage Area 650.45 355.65

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.)
Assembly
A (CHURCH) 1 711.30 711.30 711.30 711.30
Grand Total : 1 711.30 711.30 711.30 711.30


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (CHURCH)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 355.65 355.65 355.65 355.65
First Floor 355.65 355.65 355.65 355.65
Total : 711.30 711.30 711.30 711.30




[-] Building :A (CHURCH)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.)
Assembly
Ground Floor 355.65 355.65 355.65 355.65
First Floor 355.65 355.65 355.65 355.65
Total : 711.30 711.30 711.30 711.30
Total Number of Same Buildings : 1
Total : 711.30 711.30 711.30 711.30
[-] Table 4c-2

  FAR Area
Building FAR Area:711.30
Existing FAR Area :0.00
Perm.
2927.00
Prop.
711.30
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (CHURCH) 18.29 METER WIDE ROAD 12.00 12.00 6.00 6.88 6.00 9.54 6.00 6.00 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car
Reqd. Prop. Reqd./Unit Reqd. Prop.
A (CHURCH) Assembly Religious Building > 0 25 - 1 1 -
> 0 25 - - - -
Total : - - - - 1 0

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Total Car 1 12.50 0 0.00 FAILED
Total 12.50 0.00 FAILED


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (CHURCH)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.200 0.225 0.229 0.200 0.125 - 12 - - 0.000 OK
Spiral Staircase 0.750 2.105 0.200 0.206 0.250 0.150 - 14 - - 0.000 OK
Spiral Staircase 0.750 2.105 0.200 0.206 0.250 0.150 - 14 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.200 0.225 0.229 0.200 0.270 - 12 - - 0.000 Failed
Spiral Staircase 0.750 2.105 0.200 0.206 0.250 0.324 - 14 - - 0.000 Failed
Spiral Staircase 0.750 2.105 0.200 0.206 0.250 0.324 - 14 - - 0.000 Failed

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RWH - - 0.68 - - 0.93 - - 0.93 - - 0.00 OK
ENT.GATE - - 0.56 - - 0.13 - - 4.50 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (CHURCH) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (CHURCH)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 500.00 1300.89 OK
  Plot Width - 30.48 OK
  Plot Depth - 42.68 OK
  Access Width 12.20 18.29 OK
  Plot Frontage - 30.48 OK
  Coverage Area 650.45 355.65 OK
  FAR Area
Bldg. FAR Area : 711.30
Sanctioned FAR Area :0.00
2927.00 711.30 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Place of congregation, Community Hall category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Assembly Building, Margin required in Front shall be 12.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.3}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Spiral staircase shall be mini. 0.75 mt., Maximum rise 0.25 mt. & Minimum tread 0.20 mt.{As per Rule No. 43.5.4}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RWH
(3) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Hall11.43x11.55 No Rule Defined
Verandah No Rule Defined