-
No Image Found   

Detail Scrutiny Report

Dumka Nagar Parishad

Version Number: 1.0.73  
Version Date: 16/10/2020 
Report Generated On: 19-09-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDUMKA
AuthorityDUMKA NAGAR PARISHAD
Inward_NoDNP/BP/0011/W09/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDumka Town
Taluka21
Architect Details
Architect NameUDIT RAJ
License No.DNP/ARC/0002/2021
Architect AddressBAXI BANDH ROAD (BHARTIA PATHSHALA) DUMKA , JHARKHAND 814101
Architect EmailIDar.uditthakur05@gmail.com
Architect Mobile No8285454336
Plot Details
Plot Use Residential
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No578, 2196
NorthPlot No. - OTHER PLOT
SouthPlot No. - OTHER PLOT
EastRoad Width - 8.0
WestPlot No. - OTHER PLOT
Owner's Details
NameDR PRAMOD KUMAR BARNWAL AND RAKESH ROSHAN
AddressSTATION ROAD, BABU PARA NEAR GYANDA CINAMA,DUMKA
Email IDrrpshan1708@gmail.com
Mobile No8789779449
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 638.19
2 Plot area as per Document by Applicant 633.13
3 Physical area measured at site 633.13
4 Area as per Site Visit (Site Visit Report) 633.13
5Area as per Drawing 633.13

Area of Plot Considered : 633.13

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse ResiComm Bldg
Building StructureNon-Highrise
Building TypeNA
Gross Plot Area 633.13
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 633.13
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 565.22
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 67.90
67.90
Balance Plot Area 565.22

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 379.88
Proposed Coverage Area ( 49.85 % ) 315.62
Total Prop. Coverage Area ( 49.85 % ) 315.62
Balance coverage area ( 10.15 % ) 64.26
FAR CHECK
Perm. FAR Area ( 2.500 ) 1582.82
Total Perm. FAR area 1582.82
Residential FAR 672.64
Commercial FAR 81.08
Proposed FAR Area 775.36
Total Proposed FAR Area 775.36
Consumed FAR (Factor) 1.22
Balance FAR Area 807.46
BUA CHECK
Total Proposed BuiltUp Area 1004.72


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 600 meter and upto 1000 meter -
Existing Road Width 8 8.00
Proposed Road Width as per Master Plan 8 -
Road Widening Width 0 -
Plot size (as per measurement) 633.13 633.13
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 63.31 67.90 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 67.90 0.00 0.00 - 4.00 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 7 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure No Of Residential Units No Of Non-Residential Units Floor Name Floor Use Floor SubUse FAR Name FAR Use FAR SubUse
A (RESICOMM) Residential ResiComm Bldg Non-Highrise 2 2 GROUND FLOOR PLAN Commercial Shop Commercial FAR Commercial Shop
Commercial FAR Commercial Shop
TYPICAL - 1& 2 FLOOR PLAN Residential Bungalow/ Dwelling / Non Apartment Residential FAR Residential Bungalow/ Dwelling / Non Apartment
TERRACE FLOOR PLAN Residential ResiComm Bldg - - -
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESICOMM) 18.00 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESICOMM) Second Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.60 OK
First Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.60 OK
Ground Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.60 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESICOMM) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESICOMM) G + 5 3 - 4 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
379.88 315.62 OK
60% 49.85%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESICOMM) - 315.62
  Total Prop. Coverage Area - 315.62
  Total Coverage Area 379.88 315.62

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Void Parking Resi. Commercial Stair
A (RESICOMM) 1 1004.72 11.16 5.30 212.90 672.64 81.08 16.07 775.36 775.36 04
Grand Total : 1 1004.72 11.16 5.30 212.90 672.64 81.08 16.07 775.36 775.36 04


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESICOMM)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 315.62 102.72 315.62 102.72
First Floor 344.55 336.32 344.55 336.32
Second Floor 344.55 336.32 344.55 336.32
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1004.72 775.36 1004.72 775.36


[-] UnitBUA Table for Building :A (RESICOMM)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SHOP SHOP 57.72 56.05 1 2
SHOP SHOP 23.36 21.13 1
TYPICAL - 1& 2 FLOOR PLAN SPLIT UNIT FLAT 533.74 507.53 7 2
SPLIT UNIT FLAT 0.00 0.00 6
SPLIT UNIT FLAT 0.00 0.00 6
SPLIT UNIT FLAT 0.00 0.00 9
Total: - - 1148.56 1092.24 58 4


[-] Building :A (RESICOMM)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Void Parking Resi. Commercial Stair
Ground Floor 315.62 0.00 0.00 212.90 0.00 81.08 16.07 102.72 102.72 02
First Floor 344.55 5.58 2.65 0.00 336.32 0.00 0.00 336.32 336.32 01
Second Floor 344.55 5.58 2.65 0.00 336.32 0.00 0.00 336.32 336.32 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1004.72 11.16 5.30 212.90 672.64 81.08 16.07 775.36 775.36 04
Total Number of Same Buildings : 1
Total : 1004.72 11.16 5.30 212.90 672.64 81.08 16.07 775.36 775.36 04
[-] Table 4c-2

  FAR Area
Building FAR Area:775.36
Existing FAR Area :0.00
Perm.
1582.82
Prop.
775.36
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESICOMM) 8.00 METER WIDE ROAD 4.00 6.00 2.50 4.00 1.00 2.50 1.00 2.50 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (RESICOMM) 9.00 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (RESICOMM)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.90 1.90 2.94 OK
TYPICAL - 1& 2 FLOOR PLAN Lift 1.70 1.90 1.90 2.94 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.90 1.90 2.94 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (RESICOMM) Commercial Shop > 0 50 81.08 1 2 - - - - - - -
> 0 50 81.08 - - - - - - 1 4 -
Residential Bungalow/ Dwelling / Non Apartment > 0 1 2.00 1 2 - - - - - - -
> 0 1 2.00 - - - 1 1 - - - -
Total : - - - - 4 5 - 1 0 - 4 8

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 5 62.50 OK
Total Car 4 50.00 5 62.50 OK
Total Visitor Parking 1 12.50 0 0.00 FAILED
TwoWheeler - - 8 16.00 OK
Total TwoWheeler 4 8.00 8 16.00 OK
Other Parking - - - 134.40 OK
Total 70.50 228.90 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
A (RESICOMM) GROUND FLOOR PLAN DRIVEWAY 3.60 - 3.60 OK
DRIVEWAY 3.00 - 3.60 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESICOMM)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.467 0.250 0.250 0.200 0.136 - 11 - - 0.000 OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE 0.900 1.467 0.250 0.250 0.200 0.136 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.467 - 0.250 - 0.000 - 0 - - 2.500 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 1.57 - - 1.41 - - 1.42 - - 0.00 OK
ENT.GATE - - 0.45 - - 0.13 - - 3.60 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.58 - - 2.41 - - 2.42 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESICOMM) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESICOMM)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 633.13 OK
  Plot Width - 20.79 OK
  Plot Depth - 30.46 OK
  Access Width - 8.00 OK
  Plot Frontage - 22.66 OK
  Coverage Area 379.88 315.62 OK
  FAR Area
Bldg. FAR Area : 775.36
Sanctioned FAR Area :0.00
1582.82 775.36 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dumka Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 15-21 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bed Room3.18x3.13 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.40x2.50 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.40x3.00 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.40x3.06 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.40x3.08 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.41x3.13 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.65x3.00 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.65x3.10 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.76x3.00 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Foyer1.42x2.88 No Rule Defined
Hall3.90x2.07 No Rule Defined
Hall5.29x2.49 No Rule Defined
Kitchen2.72x3.13 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Kitchen3.78x2.10 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Sitout0.90x6.56 No Rule Defined
Sitout0.90x7.55 No Rule Defined
Sitout0.90x8.53 No Rule Defined
Sitout0.90x9.00 No Rule Defined
Toilet1.22x2.88 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet1.30x3.13 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet1.43x3.06 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet1.46x3.06 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet1.98x1.50 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.42x1.25 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.93x1.20 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}