General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0042/W02/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDundurya
Taluka23
Architect Details
Architect NameDEEPAK DIWAN
License No.GUNPC/ARC/0003/2017
Architect AddressS/O NIRANJAN PRASAD PALKOT ROAD,GUMLA,JAHRKHAND
Architect EmailIDgriharchitects@gmail.com
Architect Mobile No9430323454
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No397
North -
South -
East -
West -
Owner's Details
NameMANISH KUMAR AND CHANDAN KUMAR
Addressdundurya
Email IDchandankumar123221@gmail.com
Mobile No9471171306
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 183.95
2 Plot area as per Document by Applicant 183.95
3 Physical area measured at site 183.95
4 Area as per Site Visit (Site Visit Report) 182.58
5Area as per Drawing 182.29

Area of Plot Considered : 182.29

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 182.29
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 182.29
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 163.02
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 19.27
19.27
Balance Plot Area 163.02

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 127.60
Proposed Coverage Area ( 39.16 % ) 71.39
Total Prop. Coverage Area ( 39.16 % ) 71.39
Balance coverage area ( 30.84 % ) 56.21
FAR CHECK
Perm. FAR Area ( 2.00 ) 364.58
Total Perm. FAR area 364.58
Residential FAR 142.78
Proposed FAR Area 151.26
Total Proposed FAR Area 151.26
Consumed FAR (Factor) 0.83
Balance FAR Area 213.32
BUA CHECK
Total Proposed BuiltUp Area 214.17


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road -
Existing Road Width 27 27.00
Proposed Road Width as per Master Plan 25 -
Road Widening Width 0.0001 -
Plot size (as per measurement) 182.575 182.29





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)