No Image Found

Failed List Report

Gumla Nagar Parishad

Version Number: 1.0.32
Version Date: 10/05/2018
Report Generated On: 31-01-2019

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0053/W13/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMain Road
Taluka23
Architect Details
Architect NameDEEPAK DIWAN
License No.GUNPC/ARC/0003/2017
Architect AddressS/O NIRANJAN PRASAD PALKOT ROAD,GUMLA,JAHRKHAND
Architect EmailIDgriharchitects@gmail.com
Architect Mobile No9430323454
Plot Details
Plot Use Commercial
Plot SubUse Shop cum residence
PlotNearbyReligiousStructure NA
Plot/SubPlot No476
North -
South -
East -
West -
Owner's Details
NameARUNA SABOO
AddressDhobi Mahalla, Main Road Gumla
Email IDarunasaboogumla@gmail.com
Mobile No8292711126
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 192.20
2 Plot area as per Document by Applicant 192.20
3 Area as per Site Visit (Site Visit Report) 207.88
4Area as per Drawing 207.88

Area of Plot Considered : 192.20

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop cum residence
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 192.20
Deduction from Gross Plot area
- Extra Land Area 17.79
17.79
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 174.41
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 150.51
Deductions for Balance Plot Area (from Gross Plot Area)
- Extra Land Area 17.79
- Common Plot 23.90
41.69
Balance Plot Area 150.51

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 87.21
Proposed Coverage Area ( 42.64 % ) 74.37
Total Prop. Coverage Area ( 42.64 % ) 74.37
Balance coverage area ( 7.36 % ) 12.84
FAR CHECK
Perm. FAR Area ( 2.50 ) 436.03
Total Perm. FAR area 436.03
Residential FAR 88.20
Commercial FAR 148.74
Proposed FAR Area 236.94
Total Proposed FAR Area 236.94
Consumed FAR (Factor) 1.36
Balance FAR Area 194.39
BUA CHECK
Total Proposed BuiltUp Area 236.94


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 7.25 7.25
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0.15 1.98
Plot size (as per measurement) 207.88 207.88





[-] Rules
Topic Rule
Plot Level
Plot Area The depth of plot shall be max. 10 mt. for Shop-cum-Residence Building {As per Chapter VII, Rule No. 66.8}
Plot Width The depth of plot shall be max. 10 mt. for Shop-cum-Residence Building {As per Chapter VII, Rule No. 66.8}
Plot Depth The depth of plot shall be max. 10 mt. for Shop-cum-Residence Building {As per Chapter VII, Rule No. 66.8}
Plot Frontage The depth of plot shall be max. 10 mt. for Shop-cum-Residence Building {As per Chapter VII, Rule No. 66.8}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) 0.0
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) 0.0
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 21-27 mt. and Plot width upto 10 mt., Margin required in Front shall be 6.0 mt., Rear 4.0 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) - Sewage Treatment Plant
(2) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area RAIN WATER HARVESTING
(3) - SOLAR HEATING SYSTEM
Building Level (Rooms)