-
No Image Found

Check List Report

Gumla Nagar Parishad

Version Number: 1.0.37
Version Date: 29/04/2019
Report Generated On: 29-06-2019

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0046/W04/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageChetar
Taluka23
Architect Details
Architect NameDEEPAK DIWAN
License No.GUNPC/ARC/0003/2017
Architect AddressS/O NIRANJAN PRASAD PALKOT ROAD,GUMLA,JAHRKHAND
Architect EmailIDgriharchitects@gmail.com
Architect Mobile No9430323454
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No648
North -
South -
East -
West -
Owner's Details
NameVIJAY KUMAR LAL
AddressLOHARDAGA ROAD,GUMLA
Email IDabhishekram17@gmail.com
Mobile No9546350877
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 195.37
2 Physical area measured at site 195.37
3 Area as per Site Visit (Site Visit Report) 209.00
4Area as per Drawing 208.93

Area of Plot Considered : 195.37

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 195.37
Deduction from Gross Plot area
- Road Widening Area 13.71
- Surrender Free of Cost 15.57
29.27
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 166.10
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 145.68
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 13.71
- Surrender Free of Cost 15.57
- Common Plot 20.41
49.69
Balance Plot Area 145.68

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 116.27
Proposed Coverage Area ( 61.36 % ) 101.92
Total Prop. Coverage Area ( 61.36 % ) 101.92
Balance coverage area ( 8.64 % ) 14.35
FAR CHECK
Perm. FAR Area ( 1.50 ) 272.49
Total Perm. FAR area 272.49
Residential FAR 110.74
Proposed FAR Area 122.63
Total Proposed FAR Area 122.63
Consumed FAR (Factor) 0.68
Balance FAR Area 149.86
BUA CHECK
Total Proposed BuiltUp Area 212.67


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 1.95 1.25
Plot size (as per measurement) 209 208.93

Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 166.10 OK
Plot Width Mt. - - 12.46 OK
Plot Depth Mt. - - 14.42 OK
Access Width Mt. - - 3.60 OK
Plot Frontage Mt. - - 12.45 OK
Coverage Area Sq.Mt. - 116.27 101.92 OK
FAR Area Sq.Mt. - 272.49 122.63 OK
Consumed FAR Sq.Mt. - 1.50 0.68 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 16.61 20.41 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 20.41 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 6 OK
A-1 (VIJAY KUMAR LAL) Front Margin... ROAD WIDENING AREA Mt. 2.00 - 2.00 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 0.90 - 1.59 OK
Side2 Margin Mt. 0.90 - 1.00 OK
A-1 (VIJAY KUMAR LAL) BldgLine for 3.6 M.MAINROAD Mt. 1.25 4.35 OK
A-1 (VIJAY KUMAR LAL) ResvRoad Width Check for... 3.6 M.MAINROAD Mt. 1.25 1.25 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (VIJAY KUMAR LAL) Height Mt. 9.75 6.00 OK
A (VIJAY KUMAR LAL) First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
A (VIJAY KUMAR LAL) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (VIJAY KUMAR LAL) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.125 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.125 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.125 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.300 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.91 OK
Width Mt. - - 0.64 OK
Depth Mt. - - 1.43 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.90 OK
Width Mt. - - 1.29 OK
Depth Mt. - - 1.48 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.22 OK
Width Mt. - - 0.86 OK
Depth Mt. - - 1.43 OK
Height Mt. - - - OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)