No Image Found   

Detail Scrutiny Report

Gumla Nagar Parishad

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 02-03-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0005/W17/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageD.S.P Road
Taluka23
Architect Details
Architect NameDEEPAK DIWAN
License No.GUNPC/ARC/0003/2017
Architect AddressS/O NIRANJAN PRASAD PALKOT ROAD,GUMLA,JAHRKHAND
Architect EmailIDgriharchitects@gmail.com
Architect Mobile No9430323454
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No890
North -
South -
East -
West -
Owner's Details
NameJYOTI VERMA
AddressDSP ROAD,GUMLA
Email IDgriharchitects@gmail.com
Mobile No9693164618
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 197.72
2 Physical area measured at site 197.72
3 Area as per Site Visit (Site Visit Report) 197.64
4Area as per Drawing 197.72

Area of Plot Considered : 197.64

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 197.64
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 197.64
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 182.21
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 15.43
15.43
Balance Plot Area 182.21

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 138.35
Proposed Coverage Area ( 62.08 % ) 122.69
Total Prop. Coverage Area ( 62.08 % ) 122.69
Balance coverage area ( 7.92 % ) 15.66
FAR CHECK
Perm. FAR Area ( 2.00 ) 395.28
Total Perm. FAR area 395.28
Residential FAR 368.07
Proposed FAR Area 368.07
Total Proposed FAR Area 368.07
Consumed FAR (Factor) 1.86
Balance FAR Area 27.21
BUA CHECK
Total Proposed BuiltUp Area 368.07


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 7.5 7.50
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 -
Plot size (as per measurement) 197.64 197.72


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 9.88 15.43 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 15.43 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (JYOTI VERMA) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (JYOTI VERMA) 14.25 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (JYOTI VERMA) Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (JYOTI VERMA) Terrace Floor 1.00 1.20 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (JYOTI VERMA) G + 5 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
138.35 122.69 OK
70% 62.08%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (JYOTI VERMA) - 122.69
  Total Prop. Coverage Area - 122.69
  Total Coverage Area 138.35 122.69

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (JYOTI VERMA) 1 368.07 368.07 368.07 368.07 01
Grand Total : 1 368.07 368.07 368.07 368.07 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (JYOTI VERMA)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 122.69 122.69 122.69 122.69
First Floor 122.69 122.69 122.69 122.69
Second Floor 122.69 122.69 122.69 122.69
Terrace Floor 0.00 0.00 0.00 0.00
Total : 368.07 368.07 368.07 368.07


[-] UnitBUA Table for Building :A (JYOTI VERMA)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT JYOTI VERMA FLAT 368.07 366.45 9 1
TYPICAL - 1& 2 FLOOR PLAN SPLIT JYOTI VERMA FLAT 0.00 0.00 9 0
Total: - - 368.07 366.45 27 1


[-] Building :A (JYOTI VERMA)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 122.69 122.69 122.69 122.69 01
First Floor 122.69 122.69 122.69 122.69 00
Second Floor 122.69 122.69 122.69 122.69 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 368.07 368.07 368.07 368.07 01
Total Number of Same Buildings : 1
Total : 368.07 368.07 368.07 368.07 01
[-] Table 4c-2

  FAR Area
Building FAR Area:368.07
Existing FAR Area :0.00
Perm.
395.28
Prop.
368.07
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (JYOTI VERMA) 7.5.M. MAINROAD Access Road 3.00 3.00 1.80 1.85 - 0.60 0.90 1.08 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (JYOTI VERMA)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (JYOTI VERMA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 0.988 0.250 0.250 0.200 0.136 - 11 - - 0.000 OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE 0.900 0.988 0.250 0.250 0.200 0.136 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.988 - 0.250 - 0.000 - 0 - - 2.400 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 2.23 - - 0.84 - - 2.68 - - 0.00 OK
RAIN WATER HARVESTING - - 1.71 - - 0.82 - - 2.08 - - 0.00 OK
ENT.GATE - - 1.45 - - 0.32 - - 4.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.42 - - 0.68 - - 2.10 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (JYOTI VERMA)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 197.64 OK
  Plot Width - 9.15 OK
  Plot Depth - 21.61 OK
  Access Width - 7.50 OK
  Plot Frontage - 9.15 OK
  Coverage Area 138.35 122.69 OK
  FAR Area
Bldg. FAR Area : 368.07
Sanctioned FAR Area :0.00
395.28 368.07 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)