No Image Found   

Detail Scrutiny Report

Gumla Nagar Parishad

Version Number: 1.0.46  
Version Date: 22/06/2020 
Report Generated On: 24-08-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0024/W02/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDundurya
Taluka23
Architect Details
Architect NameSANTOSH KUMAR NAG
License No.GUNPC/ARC/0005/2018
Architect AddressAT - TARRI DEEPA TOLI, PO+PS- GUMLA, DIST.- GUMLA, JHARKHAND
Architect EmailIDnaag.santosh@gmail.com
Architect Mobile No9910358301
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No664
NorthPlot No. - 663
SouthPlot No. - 374
EastPlot No. - 665
WestPlot No. - 615
Owner's Details
NameJULI DEVI
AddressBANK COLONY DUNDURYA GUMLA.
Email IDnaag.santosh@gmail.com
Mobile No9431362374
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 161.93
2 Plot area as per Document by Applicant 161.93
3 Physical area measured at site 161.74
4 Area as per Site Visit (Site Visit Report) 161.75
5Area as per Drawing 161.75

Area of Plot Considered : 161.74

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 161.74
Deduction from Gross Plot area
- Surrender Free of Cost 21.84
21.84
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 139.90
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 119.27
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 21.84
- Common Plot 20.63
42.47
Balance Plot Area 119.27

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 97.93
Proposed Coverage Area ( 55.09 % ) 77.07
Total Prop. Coverage Area ( 55.09 % ) 77.07
Balance coverage area ( 14.91 % ) 20.86
FAR CHECK
Perm. FAR Area ( 1.50 ) 242.61
Total Perm. FAR area 242.61
Residential FAR 231.22
Proposed FAR Area 231.22
Total Proposed FAR Area 231.22
Consumed FAR (Factor) 1.43
Balance FAR Area 11.39
BUA CHECK
Total Proposed BuiltUp Area 231.21


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 4.15 4.20
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 1.675 1.71
Plot size (as per measurement) 161.745 161.75

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 6.99 20.63 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 20.63 0.00 0.00 - 1.87 - 90.00 ROAD WIDENING AREA(SURRENDERED FREE OF COST) OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 12 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENTIAL BUILDING G2) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENTIAL BUILDING G2) 10.00 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL BUILDING G2) Second Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.63 OK
First Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.63 OK
Ground Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.63 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENTIAL BUILDING G2) Terrace Floor 1.00 1.20 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENTIAL BUILDING G2) G + 2 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
97.93 77.07 OK
70% 55.09%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENTIAL BUILDING G2) - 77.07
  Total Prop. Coverage Area - 77.07
  Total Coverage Area 97.93 77.07

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (RESIDENTIAL BUILDING G2) 1 231.21 231.21 231.21 231.21 01
Grand Total : 1 231.21 231.21 231.21 231.21 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENTIAL BUILDING G2)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 77.07 77.07 77.07 77.07
First Floor 77.07 77.07 77.07 77.07
Second Floor 77.07 77.07 77.07 77.07
Terrace Floor 0.00 0.00 0.00 0.00
Total : 231.21 231.21 231.21 231.21


[-] UnitBUA Table for Building :A (RESIDENTIAL BUILDING G2)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 231.22 195.72 7 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 7 0
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 7 0
Total: - - 231.22 195.72 21 1


[-] Building :A (RESIDENTIAL BUILDING G2)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 77.07 77.07 77.07 77.07 01
First Floor 77.07 77.07 77.07 77.07 00
Second Floor 77.07 77.07 77.07 77.07 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 231.21 231.21 231.21 231.21 01
Total Number of Same Buildings : 1
Total : 231.21 231.21 231.21 231.21 01
[-] Table 4c-2

  FAR Area
Building FAR Area:231.22
Existing FAR Area :0.00
Perm.
242.61
Prop.
231.22
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENTIAL BUILDING G2) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 2.00 2.06 1.50 1.56 0.90 0.99 0.90 0.98 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (RESIDENTIAL BUILDING G2)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENTIAL BUILDING G2)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.136 - 11 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.136 - 11 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.136 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.000 - 0.250 - 0.000 - 0 - - 2.400 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 5.45 - - 1.41 - - 3.88 - - 0.00 OK
RAIN WATER HARVESTING - - 3.46 - - 0.94 - - 3.67 - - 0.00 OK
ENT.GATE - - 0.91 - - 0.33 - - 2.73 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.00 - - 0.95 - - 1.05 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENTIAL BUILDING G2)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT A LIVING 3.50X2.13 7.50 7.44 2.10 2.13 2.40 3.50 0.74 4.32 Failed

[-] Floor:FIRST FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT A LIVING 3.50X2.13 7.50 7.44 2.10 2.13 2.40 3.50 0.74 4.32 Failed

[-] Floor:SECOND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT A LIVING 3.50X2.13 7.50 7.44 2.10 2.13 2.40 3.50 0.74 4.32 Failed


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 139.90 OK
  Plot Width - 13.20 OK
  Plot Depth - 10.60 OK
  Access Width - 4.20 OK
  Plot Frontage - 12.80 OK
  Coverage Area 97.93 77.07 OK
  FAR Area
Bldg. FAR Area : 231.22
Sanctioned FAR Area :0.00
242.61 231.22 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)