No Image Found   

Check List Report

Gumla Nagar Parishad

Version Number: 1.0.46  
Version Date: 22/06/2020 
Report Generated On: 20-07-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0012/W20/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSarna Toli
Taluka23
Architect Details
Architect NameDEEPAK DIWAN
License No.GUNPC/ARC/0003/2017
Architect AddressS/O NIRANJAN PRASAD PALKOT ROAD,GUMLA,JAHRKHAND
Architect EmailIDgriharchitects@gmail.com
Architect Mobile No9430323454
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1404
North -
South -
East -
West -
Owner's Details
NameLEO KIRO
AddressSARNATOLI
Email IDgriharchitects@gmail.com
Mobile No7739327283
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 210.26
2 Physical area measured at site 210.26
3 Area as per Site Visit (Site Visit Report) 208.81
4Area as per Drawing 210.26

Area of Plot Considered : 208.81

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 208.81
Deduction from Gross Plot area
- Road Widening Area 26.70
26.70
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 182.11
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 169.61
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 26.70
- Common Plot 12.50
39.20
Balance Plot Area 169.61

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 127.48
Proposed Coverage Area ( 49.76 % ) 90.62
Total Prop. Coverage Area ( 49.76 % ) 90.62
Balance coverage area ( 20.24 % ) 36.86
FAR CHECK
Perm. FAR Area ( 1.20 ) 218.53
Total Perm. FAR area 218.53
Residential FAR 181.24
Proposed FAR Area 181.24
Total Proposed FAR Area 181.24
Consumed FAR (Factor) 1.00
Balance FAR Area 37.29
BUA CHECK
Total Proposed BuiltUp Area 181.24


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.5 3.50
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 2 2.00
Plot size (as per measurement) 208.81 210.26

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 182.11 OK
Plot Width Mt. - - 13.35 OK
Plot Depth Mt. - - 13.75 OK
Access Width Mt. - - 3.50 OK
Plot Frontage Mt. - - 13.35 OK
Coverage Area Sq.Mt. - 127.48 90.62 OK
FAR Area Sq.Mt. - 218.53 181.24 OK
Consumed FAR Sq.Mt. - 1.20 1.00 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 9.11 12.50 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 12.50 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 8 OK
A-1 (LEO KIRO) Front Margin... ROAD WIDENING AREA Mt. 2.00 - 2.61 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 0.90 - 3.05 OK
Side2 Margin Mt. 0.90 - 0.90 OK
A-1 (LEO KIRO) BldgLine for 3.5 M.MAINROAD Mt. 0.80 4.61 OK
A-1 (LEO KIRO) ResvRoad Width Check for... 3.5 M.MAINROAD Mt. 0.80 2.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (LEO KIRO) First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
A (LEO KIRO) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (LEO KIRO) No. of Floors No. G + 1 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.895 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.895 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.895 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.400 OK
SUMP TANK Area Sq.Mt. - - 3.14 OK
Width Mt. - - 1.04 OK
Depth Mt. - - 3.03 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 3.21 OK
Width Mt. - - 1.00 OK
Depth Mt. - - 3.22 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.62 OK
Width Mt. - - 0.47 OK
Depth Mt. - - 3.47 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.59 OK
Width Mt. - - 0.70 OK
Depth Mt. - - 2.26 OK
Height Mt. - - - OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)