Detail Scrutiny Report

Gumla Nagar Parishad

Version Number: 1.0.55  
Version Date: 16/10/2020 
Report Generated On: 03-04-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0068/W10/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageRashmi Nagar
Taluka23
Architect Details
Architect NameDEEPAK DIWAN
License No.GUNPC/ARC/0003/2017
Architect AddressS/O NIRANJAN PRASAD PALKOT ROAD,GUMLA,JAHRKHAND
Architect EmailIDgriharchitects@gmail.com
Architect Mobile No9430323454
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1317
North -
South -
East -
West -
Owner's Details
NameMILRED TOPPO
AddressDEEP NAGAR SISAI ROAD GUMLA PO/THANA - GUMLA JHARKHAND
Email IDgriharchitects@gmail.com
Mobile No8789105575
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 221.16
2 Plot area as per Document by Applicant 221.16
3 Area as per Site Visit (Site Visit Report) 240.20
4Area as per Drawing 240.20

Area of Plot Considered : 221.16

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 221.16
Deduction from Gross Plot area
- Road Widening Area 18.18
18.18
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 202.99
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 189.93
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 18.18
- Common Plot 13.06
31.23
Balance Plot Area 189.93

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 142.09
Proposed Coverage Area ( 37.88 % ) 76.89
Total Prop. Coverage Area ( 37.88 % ) 76.89
Balance coverage area ( 32.12 % ) 65.20
FAR CHECK
Perm. FAR Area ( 1.50 ) 304.49
Total Perm. FAR area 304.49
Residential FAR 112.00
Proposed FAR Area 112.00
Total Proposed FAR Area 112.00
Consumed FAR (Factor) 0.55
Balance FAR Area 192.49
BUA CHECK
Total Proposed BuiltUp Area 112.00


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 1.25
Plot size (as per measurement) 240.2 240.20
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land 19.04 19.19 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 10.15 13.06 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 13.06 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 7 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (MILRED TOPPO) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (MILRED TOPPO) 10.00 6.00 6.00 6.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (MILRED TOPPO) First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (MILRED TOPPO) Terrace Floor - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (MILRED TOPPO) G + 2 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
142.09 76.89 OK
70% 37.88%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (MILRED TOPPO) - 76.89
  Total Prop. Coverage Area - 76.89
  Total Coverage Area 142.09 76.89

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (MILRED TOPPO) 1 112.00 112.00 112.00 112.00 01
Grand Total : 1 112.00 112.00 112.00 112.00 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (MILRED TOPPO)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 76.89 76.89 76.89 76.89
First Floor 35.11 35.11 35.11 35.11
Terrace Floor 0.00 0.00 0.00 0.00
Total : 112.00 112.00 112.00 112.00


[-] UnitBUA Table for Building :A (MILRED TOPPO)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT MILRED TOPPO FLAT 112.00 99.16 6 1
FIRST FLOOR PLAN SPLIT MILRED TOPPO FLAT 0.00 0.00 3 0
Total: - - 112.00 99.16 9 1


[-] Building :A (MILRED TOPPO)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 76.89 76.89 76.89 76.89 01
First Floor 35.11 35.11 35.11 35.11 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 112.00 112.00 112.00 112.00 01
Total Number of Same Buildings : 1
Total : 112.00 112.00 112.00 112.00 01
[-] Table 4c-2

  FAR Area
Building FAR Area:112.00
Existing FAR Area :0.00
Perm.
304.49
Prop.
112.00
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (MILRED TOPPO) Extra Land 2.00 3.85 1.50 1.70 0.90 2.18 0.90 3.20 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (MILRED TOPPO) BldgLine for 3.6 m.MAINROAD Access Road 1.25 6.42 3.6 m.MAINROAD Access Road ROAD WIDENING AREA 1.25 1.25 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (MILRED TOPPO)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (MILRED TOPPO)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.125 0.225 0.250 0.200 0.136 - 11 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.125 0.225 0.250 0.200 0.136 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.125 - 0.250 - 0.000 - 0 2.100 - 2.300 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 2.23 - - 0.84 - - 2.68 - - 0.00 OK
RAIN WATER HARVESTING - - 1.71 - - 0.82 - - 2.08 - - 0.00 OK
ENT.GATE - - 0.82 - - 0.32 - - 2.56 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.42 - - 0.68 - - 2.10 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.74 - - 0.55 - - 1.35 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.74 - - 0.55 - - 1.35 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (MILRED TOPPO) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (MILRED TOPPO)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 202.99 OK
  Plot Width - 14.54 OK
  Plot Depth - 13.95 OK
  Access Width - 3.60 OK
  Plot Frontage - 14.54 OK
  Coverage Area 142.09 76.89 OK
  FAR Area
Bldg. FAR Area : 112.00
Sanctioned FAR Area :0.00
304.49 112.00 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)