No Image Found   

Check List Report

Gumla Nagar Parishad

Version Number: 1.0.55  
Version Date: 16/10/2020 
Report Generated On: 03-04-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0004/W04/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageChetar
Taluka23
Architect Details
Architect NameRAWNIT KUMAR
License No.GUNPC/ENG/0004/2019
Architect AddressVILL-PALKOT PS-PALKOT, PO-PALKOT, DIST-GUMLA
Architect EmailIDrawnitkumar5@gmail.com
Architect Mobile No6200132032
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No178
North -
South -
East -
West -
Owner's Details
NamePREM BHADUR EKKA
AddressVILL-LATHA TOLI PS -GUMLA,GHATGAON
Email IDrawnitkumar5@gmail.com
Mobile No8250701289
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 404.69
2 Physical area measured at site 404.69
3 Area as per Site Visit (Site Visit Report) 404.41
4Area as per Drawing 404.69

Area of Plot Considered : 404.41

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 404.41
Deduction from Gross Plot area
- Surrender Free of Cost 38.62
38.62
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 365.79
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 294.28
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 38.62
- Common Plot 71.51
110.13
Balance Plot Area 294.28

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 219.47
Proposed Coverage Area ( 26.42 % ) 96.64
Total Prop. Coverage Area ( 26.42 % ) 96.64
Balance coverage area ( 33.58 % ) 122.83
FAR CHECK
Perm. FAR Area ( 1.50 ) 606.61
Total Perm. FAR area 606.61
Residential FAR 193.28
Proposed FAR Area 193.28
Total Proposed FAR Area 193.28
Consumed FAR (Factor) 0.48
Balance FAR Area 413.33
BUA CHECK
Total Proposed BuiltUp Area 193.28


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 3.66 3.66
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 1.92
Plot size (as per measurement) 404.41 404.69

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 365.79 OK
Plot Width Mt. - - 20.12 OK
Plot Depth Mt. - - 18.20 OK
Access Width Mt. - - 3.66 OK
Plot Frontage Mt. - - 20.12 OK
Coverage Area Sq.Mt. - 219.47 96.64 OK
FAR Area Sq.Mt. - 606.61 193.28 OK
Consumed FAR Sq.Mt. - 1.50 0.48 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 18.29 71.51 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 71.51 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
PREM-1 (BHADUR EKKA) Front Margin... 1.92M ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 2.50 - 4.40 OK
Rear Margin Mt. 1.50 - 2.65 OK
Side1 Margin Mt. 1.00 - 7.33 OK
Side2 Margin Mt. 1.00 - 3.65 OK
PREM-1 (BHADUR EKKA) BldgLine for 3.66 MAIN ROAD Access Road Mt. 1.92 6.32 OK
PREM-1 (BHADUR EKKA) ResvRoad Width Check for... 3.66 MAIN ROAD Access Road Mt. 1.92 1.92 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
PREM (BHADUR EKKA) Height Mt. 10.00 6.40 OK
PREM (BHADUR EKKA) First Floor - Height Mt. 2.75 - 3.20 OK
First Floor - Clear Height Mt. 2.75 - 3.05 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.95 OK
Ground Floor - Height Mt. 2.75 - 3.20 OK
Ground Floor - Clear Height Mt. 2.75 - 3.05 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.95 OK
Plinth - Height Mt. 0.45 - 0.61 OK
Plinth - Clear Height Mt. - - 0.61 OK
Plinth - Beam Clear Height Mt. - - 0.61 OK
PREM (BHADUR EKKA) Terrace Floor - Height Mt. - - 1.00 OK
PREM (BHADUR EKKA) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.767 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.160 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.762 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.160 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.660 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.438 OK
SUMP TANK Area Sq.Mt. - - 3.90 OK
Width Mt. - - 1.68 OK
Depth Mt. - - 2.32 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.08 OK
Width Mt. - - 1.17 OK
Depth Mt. - - 1.18 OK
Height Mt. - - - OK
PREM (BHADUR EKKA) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road more than 100 and upto 250 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road more than 100 and upto 250 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height In New Area, for plot which lies on road less than 6.10 m. Perm. Building Ht. shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)