General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGUMLA
AuthorityGUMLA NAGAR PARISHAD
Inward_NoGUNPC/BP/0021/W17/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGokul Nagar
Taluka23
Architect Details
Architect NameDEEPAK DIWAN
License No.GUNPC/ARC/0003/2017
Architect AddressS/O NIRANJAN PRASAD PALKOT ROAD,GUMLA,JAHRKHAND
Architect EmailIDgriharchitects@gmail.com
Architect Mobile No9430323454
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No853
North -
South -
East -
West -
Owner's Details
NameANNU KUMARI
AddressGOKUL NAGAR, GUMLA
Email IDgriharchitects@gmail.com
Mobile No9334409841
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 809.66
2 Plot area as per Document by Applicant 782.10
3 Area as per Site Visit (Site Visit Report) 782.10
4Area as per Drawing 782.10

Area of Plot Considered : 782.10

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 782.10
Deduction from Gross Plot area
- Road Widening Area 36.44
36.44
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 745.66
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 663.65
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 36.44
- Common Plot 82.02
118.45
Balance Plot Area 663.65

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 447.40
Proposed Coverage Area ( 48.09 % ) 358.61
Total Prop. Coverage Area ( 48.09 % ) 358.61
Balance coverage area ( 11.91 % ) 88.79
FAR CHECK
Perm. FAR Area ( 2.000 ) 1491.32
Total Perm. FAR area 1491.32
Residential FAR 62.56
Commercial FAR 1354.79
Proposed FAR Area 1417.35
Total Proposed FAR Area 1417.35
Consumed FAR (Factor) 1.90
Balance FAR Area 73.97
BUA CHECK
Total Proposed BuiltUp Area 1434.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 6.2 6.20
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 0.65
Plot size (as per measurement) 782.1 782.10
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 745.66 OK
Plot Width Mt. - - 15.95 OK
Plot Depth Mt. - - 46.75 OK
Access Width Mt. - - 6.20 OK
Plot Frontage Mt. - - 16.50 OK
Coverage Area Sq.Mt. - 447.40 358.61 OK
FAR Area Sq.Mt. - 1491.32 1417.35 OK
Consumed FAR Sq.Mt. - 2.00 1.90 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 74.57 82.02 OK
Common Plot PlayGrounds - Minimum Area Sq.Mt. - 33.72 OK
PlayGrounds - Coverage Area Sq.Mt. - - OK
PlayGrounds - Width Mt. - 2.11 OK
PlayGrounds - Angle Degree - 87.56 OK
PlayGrounds - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 48.29 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.63 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 16 OK
Car In Area Sq.Mt. - - 37.50 OK
Four Stack.Car In Area Sq.Mt. - - 112.50 OK
Total Car In Area Sq.Mt. 150.00 - 150.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 22.00 OK
Four Stack. TwoWheeler In Area Sq.Mt. - - 54.00 OK
Total TwoWheeler In Area Sq.Mt. 68.00 - 76.00 OK
DriveWay PLOT - - - DRIVE WAY - Width No. 3.60 - 3.61 OK
PLOT - - - DRIVE WAY - Width No. 3.00 - 3.00 OK
A-1 (ANNU KUMARI) Front Margin... ROAD WIDENING AREA Mt. 8.00 - 8.91 OK
Rear Margin Mt. 5.00 - 5.09 OK
Side1 Margin Mt. 2.50 - 2.50 OK
Side2 Margin Mt. 2.50 - 2.50 OK
A-1 (ANNU KUMARI) BldgLine for 6.2 MTR WIDE ROAD Access Road Mt. 0.65 9.56 OK
A-1 (ANNU KUMARI) ResvRoad Width Check for... 6.2 MTR WIDE ROAD Access Road Mt. 0.65 0.65 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (ANNU KUMARI) Height Mt. 16.40 11.40 OK
A (ANNU KUMARI) Third Floor - Height Mt. 2.75 - 2.85 OK
Third Floor - Clear Height Mt. 2.75 - 2.75 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.40 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Clear Height Mt. 2.75 - 2.75 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.40 OK
First Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Clear Height Mt. 2.75 - 2.75 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.40 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.40 OK
A (ANNU KUMARI) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (ANNU KUMARI) No. of Floors No. G + 4 4 OK
No. of Tenements No. - 5 OK
A (ANNU KUMARI) Number Of Lift(s) No. 2 2 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. 12 12 OK
A (ANNU KUMARI) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.27 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.23 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Depth Mt. 1.90 2.27 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Depth Mt. 1.90 2.23 OK
THIRD FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
THIRD FLOOR PLAN - Lift - Depth Mt. 1.90 2.27 OK
THIRD FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
THIRD FLOOR PLAN - Lift - Depth Mt. 1.90 2.23 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.27 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.23 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.425 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.102 OK
STAIRCASE - Riser No. On Flight No. - 14 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.425 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.102 OK
STAIRCASE - Riser No. On Flight No. - 14 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.425 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.102 OK
STAIRCASE - Riser No. On Flight No. - 14 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.425 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.800 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.91 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 1.19 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.68 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 2.24 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.47 OK
Width Mt. - - 0.43 OK
Depth Mt. - - 3.47 OK
Height Mt. - - - OK
GUARD ROOM Area Sq.Mt. - 10.00 3.60 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 2.00 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.05 OK
Width Mt. - - 1.10 OK
Depth Mt. - - 1.87 OK
Height Mt. - - - OK
Area Sq.Mt. - - 1.22 OK
Width Mt. - - 0.86 OK
Depth Mt. - - 1.43 OK
Height Mt. - - - OK
Area Sq.Mt. - - 1.22 OK
Width Mt. - - 0.86 OK
Depth Mt. - - 1.43 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 2.20 OK
Width Mt. - - 1.43 OK
Depth Mt. - - 1.55 OK
Height Mt. - - - OK
A (ANNU KUMARI) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For GUMLA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 15-21 mt., Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(7) No need to check distance from Building GUARD ROOM
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
(10) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(11) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)