No Image Found

Detail Scrutiny Report

Jhumritilaiya Nagar Parishad

Version Number: 1.0.18
Version Date: 18/11/2017
Report Generated On: 14-12-2017

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0025/W02/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageTilaiya
Taluka25
Architect Details
Architect NameMD SHOAIB ALAM
License No.JNP/ENG/0001/2017
Architect AddressGUMO, NEAR MICANITE , PO - JHUMRI TELAIYA , DISTT - KODERMA
Architect EmailIDalam.construction@gmail.com
Architect Mobile No9934190015
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No5346
NorthPlot No. - SHANKAR YADAV
SouthPlot No. - SHAMBHU SINGH & BASDEV THAKUR
EastRoad Width - SURVEY ROAD
WestPlot No. - KAILSH THAKUR & OTHERS
Owner's Details
NameSRI BALESHWER PRASAD YADAV
AddressTELAIYA BASTI
Email IDyraju1277@gmail.com
Mobile No9931199425
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 202.08
2 Physical area measured at site 202.08
3 Area as per Site Visit (Site Visit Report) 202.08
4Area as per Drawing 202.08

Area of Plot Considered : 202.08

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 202.08
Deduction from Gross Plot area
- Surrender Free of Cost 1.39
1.39
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 200.69
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 179.61
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 1.39
- Common Plot 21.08
22.47
Balance Plot Area 179.61

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 140.48
Proposed Coverage Area ( 64.39 % ) 129.22
Total Prop. Coverage Area ( 64.39 % ) 129.22
Balance coverage area ( 5.61 % ) 11.26
FAR CHECK
Perm. FAR Area ( 1.80 ) 363.74
Total Perm. FAR area 363.74
Residential FAR 129.22
Proposed FAR Area 129.22
Total Proposed FAR Area 129.22
Consumed FAR (Factor) 0.64
Balance FAR Area 234.52
BUA CHECK
Total Proposed BuiltUp Area 129.22


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 4.88 4.88
Proposed Road Width as per Master Plan 4.88 -
Road Widening Width 0.001 0.12
Plot size (as per measurement) 202.08 202.08




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 20.07 21.08 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 21.08 0.00 0.00 - 2.41 - 90.00 ROAD WIDENING AREA(SURRENDERED FREE OF COST) OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BALESHWER PD YADAV) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BALESHWER PD YADAV) 9.94 2.85 2.85 2.85 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BALESHWER PD YADAV) Ground Floor 2.75 - 2.85 OK
Plinth - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BALESHWER PD YADAV) Terrace Floor 1.00 1.20 1.00 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BALESHWER PD YADAV) P + 2 1 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
140.48 129.22 OK
70% 64.39%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (BALESHWER PD YADAV) - 129.22
Total Prop. Coverage Area - 129.22
Total Coverage Area 140.48 129.22


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (BALESHWER PD YADAV) 1 129.22 129.22 129.22 129.22 01
Grand Total : 1 129.22 129.22 129.22 129.22 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BALESHWER PD YADAV)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 129.22 129.22 129.22 129.22
Terrace Floor 0.00 0.00 0.00 0.00
Total : 129.22 129.22 129.22 129.22


[-] UnitBUA Table for Building :A (BALESHWER PD YADAV) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT FLATA FLAT 65.25 62.22 6 1
Total: - - 65.25 62.22 6 1


[-] Building :A (BALESHWER PD YADAV)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 129.22 129.22 129.22 129.22 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 129.22 129.22 129.22 129.22 01
Total Number of Same Buildings : 1
Total : 129.22 129.22 129.22 129.22 01

[-] Table 4c-2

FARArea
Building FAR Area:129.22
Existing FAR Area :0.00
Perm.
363.74
Prop.
129.22
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BALESHWER PD YADAV) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 2.50 2.50 1.50 1.58 0.90 0.92 0.90 0.92 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (BALESHWER PD YADAV) BldgLine for 4.88 M WIDE ROAD 0.11 2.62 4.88 M WIDE ROAD ROAD WIDENING AREA(SURRENDERED FREE OF COST) 0.11 0.12 Ok






[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (BALESHWER PD YADAV)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BALESHWER PD YADAV)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.065 0.225 0.250 0.200 0.143 - 4 - - 0.000 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 4.76 - - 1.46 - - 3.27 - - 0.00 OK
SUMP TANK - - 4.62 - - 2.07 - - 2.23 - - 0.00 OK
RAIN WATER HARVESTING - - 4.72 - - 1.46 - - 3.24 - - 0.00 OK






[-] Floor Details (Table 9)


[-] Building:A (BALESHWER PD YADAV)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 200.69 OK
Plot Width - 11.58 OK
Plot Depth - 17.33 OK
Access Width - 4.88 OK
Plot Frontage - 11.58 OK
Coverage Area 140.48 129.22 OK
FARArea
Bldg. FAR Area : 129.22
Sanctioned FAR Area :0.00
363.74 129.22 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 4.8-6.1 mt. only Stilt + 2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)