No Image Found

Failed List Report

Jhumritilaiya Nagar Parishad

Version Number: 1.0.28
Version Date: 30/06/2018
Report Generated On: 06-09-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0017/W04/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageTilaiya
Taluka25
Architect Details
Architect NameVIKRAM INDRAJEET
License No.JNP/ENG/0002/2017
Architect AddressGANDHI SCHOOL ROAD, NEAR SHIV MANDIR, WARD NO.-25, JHUMRITELAIYA, DIST.-KODERMA
Architect EmailIDvindrajeet.1@gmail.com
Architect Mobile No9771340840
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No7347
NorthRoad Width - NH-31, RANCHI-PATNA BY PASS ROAD
SouthCTS No. - LAND OF KODARMA BLOCK
EastCTS No. - LAND OF VIJAY SINGH
WestCTS No. - LAND OF JAGDISH LAL CHHABRA
Owner's Details
NameSri SURESH KUMAR PILANIYA
AddressAt+P.O.- JHUMRITELAIYA , WARD NO.- 10, DISTRICT- KODERMA, JHARKHAND.
Email IDvindrajeet_5@rediffmail.com
Mobile No9934149149
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 196.35
2 Plot area as per Document by Applicant 196.35
3 Area as per Site Visit (Site Visit Report) 196.35
4Area as per Drawing 196.35

Area of Plot Considered : 196.35

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 196.35
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 196.35
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 168.78
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 27.57
27.57
Balance Plot Area 168.78

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 137.45
Proposed Coverage Area ( 47.03 % ) 92.35
Total Prop. Coverage Area ( 47.03 % ) 92.35
Balance coverage area ( 22.97 % ) 45.10
FAR CHECK
Perm. FAR Area ( 2.00 ) 392.70
Total Perm. FAR area 392.70
Residential FAR 277.06
Proposed FAR Area 277.06
Total Proposed FAR Area 277.06
Consumed FAR (Factor) 1.41
Balance FAR Area 115.64
BUA CHECK
Total Proposed BuiltUp Area 277.05


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 9 9.00
Proposed Road Width as per Master Plan 9 -
Road Widening Width 1 -
Plot size (as per measurement) 196.35 196.35





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)