General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0058/W07/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageJhalpo
Taluka25
Architect Details
Architect NameRAJIVA RANJAN SANDHWAR
License No.JNP/ENG/0002/2018
Architect AddressRAJIVA RANJAN SANDHWAR S/O Lt SIDHESHWAR PD SANDHWAR , GREEN GARDEN ,HESAG , HATIA
Architect EmailIDrrsandhwar@gmail.com
Architect Mobile No9507742778
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot No11
NorthRoad Width - 30M WIDE RANCHI PATNA ROAD
SouthPlot No. - LAND WITH BUILDING OF VENDEE & LAND OF SRI LAXMI PANDEY
EastPlot No. - LAND WITH BUILDING OF VENDEE'S
WestPlot No. - LAND WITH BUILDING OF SRI BITTU CHABBRA S/0 LATE MOHAN BABU
Owner's Details
Name1. SRI UMA SHANKAR PRASAD 2. SRI RAMESH KUMAR
AddressJH. TELAIYA
Email IDumashankarprasad27@gmail.com
Mobile No8809919684
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 198.80
2 Physical area measured at site 198.80
3 Area as per Site Visit (Site Visit Report) 198.80
4Area as per Drawing 198.80

Area of Plot Considered : 198.80

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 198.80
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 198.80
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 178.27
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 20.53
20.53
Balance Plot Area 178.27

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 99.40
Proposed Coverage Area ( 49.30 % ) 98.00
Total Prop. Coverage Area ( 49.3 % ) 98.00
Balance coverage area ( 0.70 % ) 1.40
FAR CHECK
Perm. FAR Area ( 2.00 ) 397.60
Total Perm. FAR area 397.60
Commercial FAR 177.29
Proposed FAR Area 194.88
Total Proposed FAR Area 194.88
Consumed FAR (Factor) 0.98
Balance FAR Area 202.72
BUA CHECK
Total Proposed BuiltUp Area 306.50


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 30 30.00
Proposed Road Width as per Master Plan 30 -
Road Widening Width 0 -
Plot size (as per measurement) 198.8 198.80


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 198.80 OK
Plot Width Sq.Mt. - - 7.10 OK
Plot Depth Sq.Mt. - - 28.00 OK
Access Width Sq.Mt. - - 30.00 OK
Plot Frontage Sq.Mt. - - 7.10 OK
Coverage Area Sq.Mt. - 99.40 98.00 OK
FAR Area Sq.Mt. - 397.60 194.88 OK
Consumed FAR Sq.Mt. - 2.00 0.98 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 9.94 20.53 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 20.53 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.80 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 6 OK
Car In Area Sq.Mt. - - 37.50 OK
Total Car In Area Sq.Mt. 37.50 - 37.50 OK
TwoWheeler In Area Sq.Mt. 14.00 - 20.00 OK
Other Parking In Area Sq.Mt. - - 42.91 OK
AA-1 (SRI UMA SHANKAR PD SRI RAMESH KUMAR) Front Margin... 30M WIDE ROAD Mt. 6.50 - 6.50 OK
Rear Margin Mt. 4.00 - 4.00 OK
Side1 Margin Mt. 1.50 - 1.50 OK
Side2 Margin Mt. - - 0.00 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
AA (SRI UMA SHANKAR PD SRI RAMESH KUMAR) Height Mt. 51.50 8.55 OK
AA (SRI UMA SHANKAR PD SRI RAMESH KUMAR) Second Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Plinth - Height Mt. 0.45 - 0.45 OK
AA (SRI UMA SHANKAR PD SRI RAMESH KUMAR) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
AA (SRI UMA SHANKAR PD SRI RAMESH KUMAR) No. of Floors No. - 3 OK
No. of Tenements No. - - OK
AA (SRI UMA SHANKAR PD SRI RAMESH KUMAR) Number Of Lift(s) No. - 2 OK
AA (SRI UMA SHANKAR PD SRI RAMESH KUMAR) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.25 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 2.25 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.26 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Depth Mt. 1.90 2.25 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Width Mt. 1.70 2.25 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Depth Mt. 1.90 2.26 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.25 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.24 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.25 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.065 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.178 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.065 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.178 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.065 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 1.400 OK
Toilet Area Sq.Mt. - 5.00 1.57 OK
Width Mt. - - 1.14 OK
Depth Mt. - - 1.38 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 1.64 OK
Width Mt. - - 1.19 OK
Depth Mt. - - 1.38 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.44 OK
Width Mt. - - 1.05 OK
Depth Mt. - - 1.38 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.75 OK
Width Mt. - - 0.22 OK
Depth Mt. - - 3.39 OK
Height Mt. - - - OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width upto 10 mt., Margin required in Front shall be 6.5 mt., Rear 4.0 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
Building Level (Rooms)