General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0001/W23/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGomo
Taluka25
Architect Details
Architect NameMD SHOAIB ALAM
License No.JNP/ENG/0001/2017
Architect AddressGUMO, NEAR MICANITE , PO - JHUMRI TELAIYA , DISTT - KODERMA
Architect EmailIDalam.construction@gmail.com
Architect Mobile No9934190015
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No5861
NorthPlot No. - OWN VENDOR
SouthRoad Width - 3.65M WIDE ROAD
EastPlot No. - RAMCHANDERA PD BARNWAL
WestPlot No. - OWN VENDOR
Owner's Details
NameSRI SANJAY PRASAD ALIAS SANJAY KUMAR BARNWAL
AddressMAHATMA GANDHI NAGAR POST+P.S- JHUMRI TELAIYA
Email IDsani_prv95@yahoo.com.in
Mobile No8521582288
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 295.42
2 Plot area as per Document by Applicant 295.42
3 Physical area measured at site 295.42
4 Area as per Site Visit (Site Visit Report) 295.42
5Area as per Drawing 295.42

Area of Plot Considered : 295.42

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 295.42
Deduction from Gross Plot area
- Surrender Free of Cost 9.30
9.30
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 286.12
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 255.64
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 9.30
- Common Plot 30.49
39.78
Balance Plot Area 255.64

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 171.67
Proposed Coverage Area ( 57.97 % ) 165.86
Total Prop. Coverage Area ( 57.97 % ) 165.86
Balance coverage area ( 2.03 % ) 5.81
FAR CHECK
Perm. FAR Area ( 1.50 ) 443.13
Total Perm. FAR area 443.13
Residential FAR 165.86
Proposed FAR Area 165.86
Total Proposed FAR Area 165.86
Consumed FAR (Factor) 0.56
Balance FAR Area 277.27
BUA CHECK
Total Proposed BuiltUp Area 165.86


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.65 3.65
Proposed Road Width as per Master Plan 3.65 -
Road Widening Width 0.01 0.72
Plot size (as per measurement) 295.42 295.42


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 286.12 OK
Plot Width Sq.Mt. - - 11.62 OK
Plot Depth Sq.Mt. - - 24.63 OK
Access Width Sq.Mt. - - 3.65 OK
Plot Frontage Sq.Mt. - - 12.95 OK
Coverage Area Sq.Mt. - 171.67 165.86 OK
FAR Area Sq.Mt. - 443.13 165.86 OK
Consumed FAR Sq.Mt. - 1.50 0.56 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 28.61 30.49 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 30.49 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.00 OK
Tree Cover (Plantation) - Angle Degree - 87.66 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 5 OK
A-1 (SANJAY PD ) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 3.01 OK
Rear Margin Mt. 1.80 - 1.80 OK
Side1 Margin Mt. 0.90 - 0.92 OK
Side2 Margin Mt. 0.90 - 1.12 OK
A-1 (SANJAY PD ) BldgLine for 3.65M WIDE ROAD Mt. 0.72 3.73 OK
A-1 (SANJAY PD ) ResvRoad Width Check for... 3.65M WIDE ROAD Mt. 0.72 0.72 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SANJAY PD ) Height Mt. 9.20 2.84 OK
A (SANJAY PD ) Ground Floor - Height Mt. 2.75 - 2.84 OK
Plinth - Height Mt. - - 0.61 OK
A (SANJAY PD ) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (SANJAY PD ) No. of Floors No. P + 2 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.041 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.149 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Toilet Area Sq.Mt. - 5.00 4.61 OK
Width Mt. - - 1.73 OK
Depth Mt. - - 2.68 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 4.61 OK
Width Mt. - - 1.73 OK
Depth Mt. - - 2.68 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 4.77 OK
Width Mt. - - 1.62 OK
Depth Mt. - - 2.94 OK
Height Mt. - - - OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only Stilt + 2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)