No Image Found

Failed List Report

Jhumritilaiya Nagar Parishad

Version Number: 1.0.27
Version Date: 18/05/2018
Report Generated On: 21-05-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0032/W18/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBhadedih
Taluka25
Architect Details
Architect NameRAJIVA RANJAN SANDHWAR
License No.JNP/ENG/0002/2018
Architect AddressRAJIVA RANJAN SANDHWAR S/O Lt SIDHESHWAR PD SANDHWAR , GREEN GARDEN ,HESAG , HATIA
Architect EmailIDrrsandhwar@gmail.com
Architect Mobile No9507742778
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No08
NorthRoad Width - 3.04M WIDE ROAD
SouthRoad Width - 30M WIDE ROAD
EastPlot No. - 3.34M WIDE ROAD
WestPlot No. - RAJENDERA MODI & RENU PD BARNWAL
Owner's Details
NameSRI SURENDRA MODI
AddressJHUMRI TELAIYA
Email IDsmodi426@gmail.com
Mobile No9931118671
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 230.20
2 Physical area measured at site 230.20
3 Area as per Site Visit (Site Visit Report) 230.20
4Area as per Drawing 230.20

Area of Plot Considered : 230.20

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 230.20
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 230.20
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 202.04
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 28.16
28.16
Balance Plot Area 202.04

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 138.12
Proposed Coverage Area ( 49.41 % ) 113.73
Total Prop. Coverage Area ( 49.41 % ) 113.73
Balance coverage area ( 10.60 % ) 24.39
FAR CHECK
Perm. FAR Area ( 2.00 ) 460.40
Total Perm. FAR area 460.40
Residential FAR 108.94
Commercial FAR 331.62
Proposed FAR Area 446.66
Total Proposed FAR Area 446.66
Consumed FAR (Factor) 1.94
Balance FAR Area 13.74
BUA CHECK
Total Proposed BuiltUp Area 570.65


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 400 meter and upto 500 meter -
Existing Road Width 30 30.00
Proposed Road Width as per Master Plan 30 -
Road Widening Width 0 -
Plot size (as per measurement) 230.2 230.20





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 27-33 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 3.0 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 12.0 mt., for every 16 flats or upto G+4 floors, No Lift is reqd. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
Building Level (Rooms)