No Image Found

Failed List Report

Jhumritilaiya Nagar Parishad

Version Number: 1.0.31
Version Date: 30/06/2018
Report Generated On: 11-01-2019

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District KODERMA
Authority JHUMRITILAIYA NAGAR PARISHAD
Inward_No JNP/BP/0003/W01/2019
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Tilaiya
Taluka 25
Architect Details
Architect Name UPENDRA
License No. JNP/ENG/0012/2017
Architect Address BYPASS ROAD, SHASTRI NAGAR, WARD No -01,
Architect EmailID nbusupendra@gmail.com
Architect Mobile No 9835362001
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 4051
North Plot No. - NARAYAN YADAV(P. N. -4051(P)
South Plot No. - YUGAL MAHTO(P. N. -4051(P)
East Road Width - 45.70mtr. wide Bypass Road
West Plot No. - YUGAL MAHTO
Owner's Details
Name RAM PRASAD MAHTO RAMAN
Address BY PASS ROAD, SHASTRI NAGAR, WARD NO 1, JHUMARI TELAIYA, DISTRTICT - KODERMA, JHARKHAND
Email ID upendra.nbus@gmail.com
Mobile No 8862904603
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 314.45
2 Plot area as per Document by Applicant 314.45
3 Physical area measured at site 314.45
4 Area as per Site Visit (Site Visit Report) 314.45
5 Area as per Drawing 314.45

Area of Plot Considered : 314.45

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot RESI PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 314.45
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 314.45
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 281.03
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 33.41
33.41
Balance Plot Area 281.03

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 188.67
Proposed Coverage Area ( 42.08 % ) 132.31
Total Prop. Coverage Area ( 42.08 % ) 132.31
Balance coverage area ( 17.92 % ) 56.36
FAR CHECK
Perm. FAR Area ( 2.00 ) 628.90
Total Perm. FAR area 628.90
Residential FAR 264.63
Proposed FAR Area 264.63
Total Proposed FAR Area 264.63
Consumed FAR (Factor) 0.84
Balance FAR Area 364.27
BUA CHECK
Total Proposed BuiltUp Area 264.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 45.7 45.70
Proposed Road Width as per Master Plan 45.7 -
Road Widening Width 0 -
Plot size (as per measurement) 314.45 314.45





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)